Effects of oxytocin on high intensity focused ultrasound (HIFU) ablation of adenomysis: A prospective study

article OA: closed CC0 ⤵ 13 in-corpus citations
View on OpenAlex View on PubMed View at publisher
AI-generated summary by claude@2026-06, 2026-06-09

This prospective study investigated the effects of oxytocin on high-intensity focused ultrasound (HIFU) ablation of adenomyosis.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

ObjectiveTo investigate the effects of oxytocin on high-intensity focused ultrasound (HIFU) ablation for the treatment of adenomyosis.Materials and methodsEighty-six patients with adenomyosis from three hospitals were randomly assigned to the oxytocin group or control group for HIFU treatment. During HIFU treatment, 80 units of oxytocin was added in 500ml of 0.9% normal saline running at the rate of 2ml/min (0.32U/min) in the oxytocin group, while 0.9% normal saline was used in the control group. Both patients and HIFU operators were blinded to oxytocin or saline application. Treatment results, adverse effects were compared.ResultsWhen using oxytocin, the non-perfused volume (NPV) ratio was 80.7±11.6%, the energy-efficiency factor (EEF) was 8.1±9.9J/mm(3), and the sonication time required to ablate 1cm(3) was 30.0±36.0s/cm(3). When not using oxytocin, the non-perfused volume ratio was 70.8±16.7%, the EEF was 15.8±19.6J/mm(3), and the sonication time required to ablate 1cm(3) was 58.2±72.7S/cm(3). Significant difference in the NPV ratio, EEF, and the sonication time required to ablate 1cm(3) between the two groups was observed. No oxytocin related adverse effects occurred.ConclusionOxytocin could significantly decrease the energy for ablating adenomyosis with HIFU, safely enhance the treatment efficiency.

My notes (saved in your browser only)

MeSH descriptors

Adenomyosis High-Intensity Focused Ultrasound Ablation Oxytocics Oxytocin Adenomyosis Adult Female Follow-Up Studies Gadolinium High-Intensity Focused Ultrasound Ablation Humans Image Enhancement Image Enhancement Magnetic Resonance Imaging Magnetic Resonance Imaging Oxytocics Oxytocin Prospective Studies Time Factors Treatment Outcome

Citation neighborhood

Papers in the corpus that this work cites (lower rings, blue) and that cite this one (upper rings, green). Dot size scales with the paper's in-corpus citation count — bigger dot = more influential within the endo/adeno field. Click a dot to open that paper. [ expand to 2 hops ] — adds papers reached through this work's immediate citers/citees. Heavier; up to 60 extra dots.

References (24)

Cited by (14)

Source provenance

europepmc
last seen: 2026-07-26T06:08:39.051465+00:00
openalex
last seen: 2026-06-10T17:14:06.276822+00:00
pubmed
last seen: 2026-05-13T22:18:22.440000+00:00
unpaywall
last seen: 2026-06-13T06:42:57.164913+00:00
License: CC0 · commercial use OK