High intensity focused ultrasound treatment of adenomyosis: The relationship between the features of magnetic resonance imaging on T2 weighted images and the therapeutic efficacy

Non-randomised trial OA: closed CC0 ⤵ 21 in-corpus citations
⚙ AI-generated summary by gemini-2.5-flash-lite, 2026-06-07 ⓘ

This study investigates the correlation between magnetic resonance imaging features on T2 weighted images and the therapeutic efficacy of high-intensity focused ultrasound (HIFU) treatment for adenomyosis.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

OBJECTIVES: To investigate the relationship between the features of magnetic resonance imaging (MRI) on T2 weighted images (T2WI) and the therapeutic efficacy of high intensity focused ultrasound (HIFU) on adenomyosis. MATERIALS AND METHODS: From January 2011 to November 2015, four hundred and twenty-eight patients with symptomatic adenomyosis were treated with HIFU. Based on the signal intensity and the number of hyperintense foci in the adenomyotic lesions on T2WI, the patients were classified into groups. The day after HIFU ablation patients underwent contrast-enhanced MRI and a comparison was made of non-perfused volume (NPV) ratio, energy efficiency factor (EEF), treatment time, sonication time, and adverse effects. RESULTS: No significant difference in terms of HIFU treatment settings and results was observed between the group of patients with hypointense adenomyotic lesions and the group with isointense adenomyotic lesions (P>0.05). However, the sonication time and EEF were significantly higher in the group with multiple hyperintense foci compared to the group with few hyperintense foci. The NPV ratio achieved in the lesions with multiple hyperintenese foci was significantly lower than that in the lesions with few hyperintense foci (P<0.05). No significant difference was observed in the rate of adverse effects between the two groups. CONCLUSIONS: Based on our results, the response of the adenomyotic lesions to HIFU treatment is not related to the signal intensity of adenomyotic lesions on T2WI. However, the number of the high signal intensity foci in the adenomyotic lesions on T2WI can be considered as a predictive factor to help select patients for HIFU treatment.

My notes (saved in your browser only)

Condition tags

adenomyosis

MeSH descriptors

Adenomyosis High-Intensity Focused Ultrasound Ablation Adenomyosis Adenomyosis Adult Adult Female Female High-Intensity Focused Ultrasound Ablation High-Intensity Focused Ultrasound Ablation Humans Humans Magnetic Resonance Imaging Magnetic Resonance Imaging Magnetic Resonance Imaging Middle Aged Middle Aged Retrospective Studies Retrospective Studies Treatment Outcome

Citation neighborhood (2-hop)

Papers in the corpus that this work cites (lower rings, blue) and that cite this one (upper rings, green). Dot size scales with the paper's in-corpus citation count — bigger dot = more influential within the endo/adeno field. Click a dot to open that paper. Outer rings show 2-hop neighbours — papers reached through the immediate citers/citees. [ collapse to 1-hop ]

References (20)

Cited by (21)

Source provenance

europepmc
last seen: 2026-10-17T06:09:56.316927+00:00
openalex
last seen: 2026-06-10T17:14:06.276822+00:00
pubmed
last seen: 2026-10-08T21:19:26.535059+00:00
unpaywall
last seen: 2026-09-17T06:32:46.214484+00:00
License: CC0 · commercial use OK