Automated detection and measurement of uterine peristalsis in cine MR images
Other
OA: bronze
CC0
⤵ 9 in-corpus citations
AI-generated summary
Automated software quantified uterine peristalsis on cine MRI with excellent agreement to visual evaluations, comparable to interreader agreement.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
Abstract
PURPOSE: To evaluate the ability of automated software to quantify uterine peristalsis on cine magnetic resonance imaging (MRI).
MATERIALS AND METHODS: At 1.5T, half-Fourier acquisition single-shot turbo spin echo (HASTE) techniques were used to obtain 60 serial images over 3 minutes (TR/TE 3000/80 msec) in a midsagittal plane of the uterus. Thirty-two cine MR datasets, obtained from 16 healthy females, were analyzed. Uterine peristalsis was defined as the traveling waves of decreasing signal intensity on the endometrium-junctional zone border. The software detected traveling waves by identifying the neighboring areas showing similar patterns of signal intensity decrease in a different timing. Quantification of uterine peristaltic wave using the fully automated software was compared to qualitative visual evaluation by two readers.
RESULTS: The mean number (and standard deviation) of peristaltic waves detected by the fully automated software and visual evaluations (readers 1 and 2) were 5.4 (3.0), 4.7 (3.1), and 4.5 (3.1) per 3 minutes, respectively. Quantification by fully automated software demonstrated excellent agreement with repeated measurement (weighted kappa 0.99) and with qualitative visual evaluations (range 0.89-0.95), comparable to interreader agreement by visual evaluations (range 0.89-0.93).
CONCLUSION: The fully automated software can be used to quantify uterine peristalsis comparable to visual evaluation.
My notes (saved in your browser only)
MeSH descriptors
Citation neighborhood (2-hop)
Papers in the corpus that this work cites (lower rings, blue) and that cite this one (upper rings, green). Dot size scales with the paper's in-corpus citation count — bigger dot = more influential within the endo/adeno field. Click a dot to open that paper. Outer rings show 2-hop neighbours — papers reached through the immediate citers/citees. [ collapse to 1-hop ]
References (10)
- A semiautomated technique for evaluation of uterine peristalsis via openalex
- doi:10.1007/bf00133570 via openalex
- W1480546554 via openalex
- doi:10.1016/j.jmig.2011.09.010 via openalex
- doi:10.2307/2529310 via openalex
- doi:10.1016/j.mri.2007.06.001 via openalex
- doi:10.1002/jmri.20384 via openalex
- doi:10.1002/jmri.10415 via openalex
- doi:10.1148/rg.e19 via openalex
- doi:10.1007/s00330-006-0494-9 via openalex
Cited by (8)
- The ElectroUteroGraph: A Novel Tool for Assessing Uterine Contractions of Non-Pregnant Women 2022
- Automated measurement of endometrial peristalsis in cine transvaginal ultrasound images 2022
- A Quantification Approach of Uterine Peristalsis Propagated From the Cervix and the Fundus 2019
- Visual inspection of transvaginal ultrasound videos to characterize uterine peristalsis: an inter-observer agreement study 2019
- An optimised repetition time (TR) for cine imaging of uterine peristalsis on 3 T MRI 2018
- Objective Analysis of Vaginal Ultrasound Video Clips for Exploring Uterine Peristalsis Post Vaginal and Cesarean Section Deliveries 2017
- Biomechanics of the human uterus 2017
- Optimized approach to cine MRI of uterine peristalsis 2016
Source provenance
- openalex
- last seen: 2026-05-11T03:41:04.528306+00:00
- pubmed
- last seen: 2026-10-08T21:14:41.184593+00:00
License: CC0
· commercial use OK