Optimizing cine MRI for uterine peristalsis: a comparison of three different single shot fast spin echo techniques
Other
OA: closed
CC0
⤵ 8 in-corpus citations
AI-generated summary
Cine MRI using a 4-second interval single-shot fast spin echo sequence optimized uterine peristalsis detection by increasing frequency, direction, intensity, and contrast-to-noise ratios.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
Abstract
PURPOSE: To determine the optimal single shot fast spin echo (SSFSE) technique by varying interval between image acquisitions for cine MRI of uterine peristalsis.
MATERIALS AND METHODS: MRI was performed in 13 premenopausal women (4 normal and 9 with benign pelvic pathology) in various phases of their menstrual cycle. Midsagittal uterus was scanned using a multiphasic SSFSE technique at 2-, 3-, and 4-s intervals over 2 min. Three readers independently and randomly evaluated for peristaltic frequency/2 min, longitudinal direction and intensity of peristalsis in three imaging parameters. Contrast-to-noise ratios (CNRs) were also obtained.
RESULTS: Peristaltic frequency for the 2, 3, and 4 s was 2.2 ± 2.3, 3.3 ± 1.5, and 3.6 ± 1.3 waves/2 min, respectively. It increased by 1.5 (95% confidence interval [CI]: 0.31-2.64) waves/2 min with 4 s compared with 2 s. Direction was detected for the 2, 3, and 4 s in 5/13(38%), 9/13(69%) and 12/13(92%) women. Compared with 2 s, intensity of peristalsis in endometrial movement (P = 0.04), signal change of the JZ (P = 0.03), and spread into outer myometrium (P = 0.02), CNRendometrium-JZ by 57% (P < 0.001), and CNRouter myometrium-JZ by 45% (P < 0.01) increased with 4 s.
CONCLUSION: Cine MRI with SSFSE sequence for uterine peristaltism is best performed using a 4-s scan interval.
My notes (saved in your browser only)
MeSH descriptors
Citation neighborhood (2-hop)
Papers in the corpus that this work cites (lower rings, blue) and that cite this one (upper rings, green). Dot size scales with the paper's in-corpus citation count — bigger dot = more influential within the endo/adeno field. Click a dot to open that paper. Outer rings show 2-hop neighbours — papers reached through the immediate citers/citees. [ collapse to 1-hop ]
References (16)
- Characterization of subendometrial myometrial contractions throughout the menstrual cycle in normal fertile women via openalex
- Uterine peristaltic activity during the menstrual cycle: characterization, regulation, function and dysfunction via openalex
- doi:10.1148/rg.e19 via openalex
- doi:10.1002/jmri.20010 via openalex
- doi:10.1016/0002-9378(90)90983-e via openalex
- doi:10.1093/humrep/11.3.627 via openalex
- doi:10.1002/1522-2594(200009)44:3<339::aid-mrm1>3.0.co;2-n via openalex
- doi:10.2307/2529310 via openalex
- doi:10.1002/jmri.20140 via openalex
- doi:10.1097/00004728-199201000-00008 via openalex
- doi:10.1016/j.ejrad.2004.01.009 via openalex
- doi:10.1007/s00330-006-0494-9 via openalex
- doi:10.1148/radiol.2351031283 via openalex
- doi:10.1002/jmri.10415 via openalex
- doi:10.1016/0002-9378(66)90678-8 via openalex
- doi:10.1111/j.1749-6632.1997.tb48543.x via openalex
Cited by (8)
- Safety and efficacy of magnetic resonance-guided high-intensity focused ultrasound surgery (MRgFUS) in adenomyosis with dysmenorrhea 2026
- MRI of Adenomyosis: Where Are We Today? 2022
- Automated measurement of endometrial peristalsis in cine transvaginal ultrasound images 2022
- MRI of Adenomyosis: Where Are We Today? 2022
- Visual inspection of transvaginal ultrasound videos to characterize uterine peristalsis: an inter-observer agreement study 2019
- An optimised repetition time (TR) for cine imaging of uterine peristalsis on 3 T MRI 2018
- Benign Gynecologic Conditions of the Uterus 2017
- Optimized approach to cine MRI of uterine peristalsis 2016
Source provenance
- openalex
- last seen: 2026-05-11T06:12:37.668444+00:00
- pubmed
- last seen: 2026-10-08T21:11:10.042802+00:00
License: CC0
· commercial use OK