En-block butterfly excision of posterior compartment deep endometriosis: The first experience with the new surgical robot Hugo™ RAS

article OA: bronze CC0 ⤵ 4 in-corpus citations
AI-generated summary by claude@2026-06, 2026-06-09

This paper describes the first robotic en-bloc excision of deep posterior compartment endometriosis using the Hugo RAS system in a patient who experienced complete symptom relief without complications.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

Background: Minimally invasive surgery is the gold standard treatment for deep endometriosis when medical management fails. In selected cases, such as when bowel or urinary tract are involved, robotic assisted surgery can be useful due to its characteristics of high dexterity and manoeuvrability. This is the first case of robotic en-bloc excision of posterior compartment deep endometriosis performed with the new HugoTM RAS system. Objective: The purpose of this video article is to show for the first time the feasibility of bowel surgery for deep endometriosis with this new robotic device. Materials and Methods: A 24-years-old woman affected by severe dysmenorrhea, chronic pelvic pain, dyschezia and dyspareunia underwent to deep endometriosis excision using the new robotic platform HugoTM RAS system at the Unit of Gynaecological Oncology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy. Main outcome measures: Intraoperative data, docking set up, post-operative outcomes up to three months follow up were evaluated. Results: The surgical procedure was carried out without intra-operative or post-operative complications, operative time (OT) was 200 minutes, while docking time was 8 minutes. No system errors or faults in the robotic arms were registered. Post-operative complete disease-related symptoms relief was reported. Conclusion: According to our results, the introduction of this new robotic platform in the surgical management of deep endometriosis seems to be feasible, especially in advanced cases. However, further studies are needed to demonstrate the benefits of this surgical system and the advantages of robotic surgery compared to laparoscopy in this subset of patients.
Full text 1,722 characters · extracted from oa-doi-fallback · 5 sections · click to expand

Abstract

Background Minimally invasive surgery is the gold standard treatment for deep endometriosis when medical management fails. In selected cases, such as when bowel or urinary tract are involved, robotic assisted surgery can be useful due to its characteristics of high dexterity and manoeuvrability. This is the first case of robotic en-bloc excision of posterior compartment deep endometriosis performed with the new HugoTM RAS system.

Objective

The purpose of this video article is to show for the first time the feasibility of bowel surgery for deep endometriosis with this new robotic device.

Materials and methods

A 24-years-old woman affected by severe dysmenorrhea, chronic pelvic pain, dyschezia and dyspareunia underwent to deep endometriosis excision using the new robotic platform HugoTM RAS system at the Unit of Gynaecological Oncology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy. Main outcome measures Intraoperative data, docking set up, post-operative outcomes up to three months follow up were evaluated.

Results

The surgical procedure was carried out without intra-operative or post-operative complications, operative time (OT) was 200 minutes, while docking time was 8 minutes. No system errors or faults in the robotic arms were registered. Post-operative complete disease-related symptoms relief was reported.

Conclusion

According to our results, the introduction of this new robotic platform in the surgical management of deep endometriosis seems to be feasible, especially in advanced cases. However, further studies are needed to demonstrate the benefits of this surgical system and the advantages of robotic surgery compared to laparoscopy in this subset of patients.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Condition tags

endometriosischronic_pelvic_paindysmenorrheadyspareunia

Citation neighborhood

Papers in the corpus that this work cites (lower rings, blue) and that cite this one (upper rings, green). Dot size scales with the paper's in-corpus citation count — bigger dot = more influential within the endo/adeno field. Click a dot to open that paper. [ expand to 2 hops ] — adds papers reached through this work's immediate citers/citees. Heavier; up to 60 extra dots.

References (18)

Cited by (4)

Source provenance

europepmc
last seen: 2026-06-04T01:30:01.192114+00:00
openalex
last seen: 2026-06-04T00:00:01.174412+00:00
pubmed
last seen: 2026-05-23T00:33:15.267617+00:00
License: CC0 · commercial use OK