Transvaginal Ultrasonography and Saline Infusion Sonography Compared to Hysteroscopy for Diagnosis of Intracavity Lesion: A 4-Year Experience in Suburban Referral Hospital
article
OA: closed
CC0
Abstract
Objective: To evaluate the accuracy of transvaginal ultrasonography (TVS) and saline infusion sonography (SIS) in use for the diagnosis of endometrial polyps and submucous myoma compared to hysteroscopy. Histopathology was considered as the gold standard for final diagnosis. Materials and Methods: The present retrospective study was conducted at Bhumibol Adulyadej Hospital, Bangkok, Thailand between January 2014 and December 2017. Medical records of 150 patients who attended for hysteroscopy and histopathological diagnosis were reviewed. The accuracy of TVS and SIS for the diagnosis of endometrial polyps and submucous myoma were determined. Results: Out of 150 enrolled cases, endometrial polyp was the most frequent hysteroscopic finding in participants of the present study (92/150). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of TVS, SIS, and hysteroscopy compared to pathologic reports for detection endometrial polyps were 71.7% versus 93.5% versus 97.8%, 38.5% versus 52.2% versus 68.2%, 80.5% versus 88.7% versus 92.8%, 27.8% versus 66.7% versus 88.2%, and 64.4% versus 85.2% versus 92.1%, respectively. The sensitivity, specificity, PPV, NPV, and accuracy of TVS, SIS, and hysteroscopy for detection of submucous myoma were 81.6% versus 92.1% versus 94.7%, 66.7% versus 86.9% versus 100%, 77.5% versus 92.1% versus 100%, 72.0% versus 86.9% versus 90.9%, and 75.4% versus 90.2% versus 96.6%, respectively. The kappa value from TVS, SIS, and hysteroscopy when the histopathologic reports were overall intrauterine abnormalities, endometrial polyps and submucous myoma were 0.45/0.43/0.72, 0.77/0.76/0.89, and 0.92/0.92/1.00, respectively. Conclusion: Sensitivity, specificity, PPV, NPV, accuracy, and kappa value of SIS for detecting endometrial polyps and submucous myoma were better than TVS. Keywords: Ultrasonography, Saline infusion sonography, Hysteroscopy, Accuracy
My notes (saved in your browser only)
Citation neighborhood (sparse)
Too few in-corpus citations on either side for a chart; here are the lists.
Cites (2)
References (19)
- Three-dimensional saline infusion sonography compared to two-dimensional saline infusion sonography for the diagnosis of focal intracavitary lesions via openalex
- Transvaginal Ultrasound for the Diagnosis of Abnormal Uterine Bleeding via openalex
- W2079228656 via openalex
- W2117923798 via openalex
- W2131636236 via openalex
- W2163801461 via openalex
- W2172225468 via openalex
- W2332167697 via openalex
- W2517390688 via openalex
- W2528494380 via openalex
- W2552541000 via openalex
- W2554984574 via openalex
- W2610596789 via openalex
- W2745050740 via openalex
- W2784199785 via openalex
- W4243012773 via openalex
- W1490913181 via openalex
- W4294214983 via openalex
- W2055554149 via openalex
Source provenance
- openalex
- last seen: 2026-06-04T00:00:01.174412+00:00
License: CC0
· commercial use OK