Risk of ectopic pregnancy is linked to endometrial thickness in a retrospective cohort study of 8120 assisted reproduction technology cycles
article
OA: bronze
CC0
⤵ 3 in-corpus citations
AI-generated summary
Endometrial combined thickness less than 9 mm is associated with a four-fold increased risk of ectopic pregnancy following assisted reproduction technology cycles.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
Abstract
STUDY QUESTION: Is endometrial combined thickness (ECT) measured prior to embryo transfer (ET) associated with ectopic pregnancy (EP)? SUMMARY ANSWER: Following IVF, the risk of EP is 4-fold increased in women with an ECT of 12 mm. WHAT IS KNOWN ALREADY: Known risk factors for EP include tubal damage, maternal cigarette smoking and endometriosis. EP is also more common following IVF but the underlying causes for this remain unclear. STUDY DESIGN, SIZE, DURATION: Retrospective cohort study restricted to all IVF cycles leading to a pregnancy (βhCG > 50 IU/l) between January 2006 and December 2014. A total of 6465 patients achieved a pregnancy in 8120 cycles. Cycles using preimplantation genetic screening or donor oocytes were excluded. PARTICIPANTS/MATERIALS, SETTING, METHODS: This cohort consists of 6465 patients achieving a pregnancy in 6920 stimulated cycles with fresh embryo transfers (STIM ET) and 1200 hormone replacement therapy frozen embryo transfers (HRT-FET) cycles at a private IVF unit (Monash IVF, Melbourne, Australia). ECT was the primary independent variable of interest; the primary outcome was a diagnosis of EP. The dataset was analysed using binary logistic general estimating equations (SPSS v22.0) to calculate odds ratio (OR) for EP adjusted for known confounders (aOR). There was no loss to follow-up in the dataset. MAIN RESULTS AND THE ROLE OF CHANCE: The study groups did not differ significantly prior to IVF treatment. After adjusting for confounders, ECT remained statistically significant as an independent risk factor for EP. Compared with women with an ECT of <9 mm, women with an ECT of 9-12 mm had an aOR of 0.44 (95% CI 0.29-0.69, P 12 mm had an aOR of 0.27 (95% CI 0.10-0.77, P = 0.01). These differences remained statistically significant after performing a sensitivity analysis excluding HRT-FET, smokers and patients with tubal infertility. LIMITATIONS, REASONS FOR CAUTION: The study design is retrospective, and it is possible that not all confounders have been accounted for. Measurement of ECT was performed by highly trained sonographers, but some inconsistency between individuals may be present. WIDER IMPLICATIONS OF THE FINDINGS: Our group has previously demonstrated an increased risk of placenta praevia with increased ECT. These new findings suggest that the directionality of the uterine peristalsis waves matters more than their frequency or amplitude. Combining the data from both studies we now hypothesize that increased ECT is a marker for increased fundus-to-cervix uterine peristalsis, explaining both the increased placenta praevia risk and the lower EP risk. Further prospective studies are required to confirm these observations.
My notes (saved in your browser only)
Condition tags
MeSH descriptors
Citation neighborhood (sparse)
Too few in-corpus citations on either side for a chart; here are the lists.
Cites (2)
- Influence of controlled ovarian hyperstimulation on uterine peristalsis in infertile women 2012
- Uterine peristalsis exerts control over fluid migration after mock embryo transfer 2013
Cited by (3)
- Abdominal ectopic pregnancy after in vitro fertilization and single embryo transfer: a case report and systematic review 2016
- Low body mass index is associated with ectopic pregnancy following assisted reproductive techniques: a retrospective study 2020
- Endometriosis and Beta-hCG > 775 IU/l Increase the Risk of Non-tube-preserving Surgery for Tubal Pregnancy 2018
References (26)
- Influence of controlled ovarian hyperstimulation on uterine peristalsis in infertile women via openalex
- Uterine peristalsis exerts control over fluid migration after mock embryo transfer via openalex
- W1864844984 via openalex
- W1966855328 via openalex
- W1981141527 via openalex
- W2000997701 via openalex
- W2005683955 via openalex
- W2010564246 via openalex
- W2041878395 via openalex
- W2054410490 via openalex
- W2072009800 via openalex
- W2072295289 via openalex
- W2074068030 via openalex
- W2085593580 via openalex
- W2093179291 via openalex
- W2097149308 via openalex
- W2097443687 via openalex
- W2102488665 via openalex
- W2151411066 via openalex
- W2152312712 via openalex
- W2156165411 via openalex
- W2160976668 via openalex
- W2161602212 via openalex
- W173284502 via openalex
- W4210953179 via openalex
- W1790923081 via openalex
Cited by (3)
- Low body mass index is associated with ectopic pregnancy following assisted reproductive techniques: a retrospective study 2020
- Endometriosis and Beta-hCG > 775 IU/l Increase the Risk of Non-tube-preserving Surgery for Tubal Pregnancy 2018
- Abdominal ectopic pregnancy after in vitro fertilization and single embryo transfer: a case report and systematic review 2016
Source provenance
- europepmc
- last seen: 2026-06-04T01:30:01.192114+00:00
- openalex
- last seen: 2026-06-04T00:00:01.174412+00:00
- pubmed
- last seen: 2026-05-13T22:17:39.907309+00:00
License: CC0
· commercial use OK