Ultrastructural evaluation following catheterization of the fallopian tube with a hysteroscopic catheter

Non-randomised trial OA: closed
📄 Open PDF View on PubMed View at publisher
⚙ AI-generated summary by gemini-2.5-flash-lite, 2026-08-03 ⓘ

This study used electron microscopy to evaluate the ultrastructural morphology of fallopian tubes after hysteroscopic catheterization, finding no significant acute damage to the tubal epithelium.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

PURPOSE: Our purpose was to assess the morphology and ultrastructural changes in the tubal epithelium following catheterization of the fallopian tube. METHODS: Fallopian tubes were obtained from 20 women who had undergone hysterectomies. Catheterization was performed in 20 tubes using a catheter developed for hysteroscopic tubal embryo transfer. The catheter has a 3-French diameter, tapering to 2 French (0.66 mm) at the tip portion. The 20 contralateral tubes served as controls and were not catheterized. Ultrastructural changes were examined by scanning electron microscopy and transmission electron microscopy. RESULTS: Scanning electron microscopy showed no transformation or defects of the tubal epithelium surface in catheterized or control tubes. Transmission electron microscopy showed no significant differences in the percentage of abnormal desmosomes and the percentage of basement membrane in ciliated and nonciliated cells between catheterized and noncatheterized tubes. No transformation or defects were observed in catheterized or noncatheterized tubes. CONCLUSIONS: These findings suggest that catheterization of the tube using a hysteroscopic catheter caused no acute damage to the tubal epithelium.

My notes (saved in your browser only)

MeSH descriptors

Catheterization Fallopian Tubes Basement Membrane Basement Membrane Cilia Cilia Desmosomes Desmosomes Embryo Transfer Embryo Transfer Epithelial Cells Epithelial Cells Fallopian Tubes Female Humans Hysterectomy Hysteroscopy Microscopy, Electron Microscopy, Electron, Scanning Microvilli

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-10-11T09:27:45.537177+00:00
pubmed
last seen: 2026-10-08T22:00:41.816812+00:00