Suture-fixation of a levonorgestrel-releasing intrauterine device under hysteroscopic guidance

In: Facts, Views and Vision in ObGyn · 2023 · vol. 15(4) , pp. 355–358 · doi:10.52054/fvvo.15.4.107 · W4390120346
article OA: bronze CC0 ⤵ 2 in-corpus citations
AI-generated summary by claude@2026-06, 2026-06-09

This paper demonstrates a minimally invasive hysteroscopy-guided suture fixation technique for levonorgestrel-releasing intrauterine devices in a patient with a history of expulsion.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

Background: Abnormal uterine bleeding (AUB) is a common gynaecological condition. The levonorgestrel-releasing Intrauterine device (LNG-IUD) is an effective medical treatment. option which carries a small risk of device expulsion. For those who experience expulsion, some may benefit from a more robust surgical approach. Objectives: To demonstrate the technique for suture fixation of an LNG-IUD under hysteroscopic guidance. Materials and methods: Stepwise video demonstration of the technique using a 5mm hysteroscope and a 3mm laparoscopic needle holder. The Institutional Ethical Committee was consulted, and the requirement for approval was waived because the video described a modified surgical technique. Informed consent was obtained from the patient. Main outcome measures: A 35yr old parous woman with a nine-month history of AUB and severe dysmenorrhoea had an LNG-IUD sited with effective symptom relief. Unfortunately, the device was expelled six months after insertion, and she responded poorly to other medical treatments. Transvaginal ultrasonography (TVUS) suggested posterior wall adenomyosis. Considering her relief of symptoms with the LNG-IUD and history of expulsion, the patient was counselled regarding suture-fixation of the LNG-IUD. Results: She was followed-up at 6 months post insertion. The LNG-IUD was noted in the uterine cavity without displacement or expulsion. Conclusion: Hysteroscopy-guided suture fixation of an LNG-IUD is a minimally invasive, effective option for patients with a history of expulsion of an IUD. However, further studies are required to establish the safety and efficacy of this approach. Learning Objective: To demonstrate LNG -IUD suture fixation technique using hysteroscopy for patients diagnosed with AUB and a history of device expulsion.
Full text 1,809 characters · extracted from oa-doi-fallback · 4 sections · click to expand

Abstract

Background: Abnormal uterine bleeding (AUB) is a common gynaecological condition. The levonorgestrel-releasing Intrauterine device (LNG-IUD) is an effective medical treatment. option which carries a small risk of device expulsion. For those who experience expulsion, some may benefit from a more robust surgical approach.

Objectives

To demonstrate the technique for suture fixation of an LNG-IUD under hysteroscopic guidance. Materials and methods: Stepwise video demonstration of the technique using a 5mm hysteroscope and a 3mm laparoscopic needle holder. The Institutional Ethical Committee was consulted, and the requirement for approval was waived because the video described a modified surgical technique. Informed consent was obtained from the patient. Main outcome measures: A 35yr old parous woman with a nine-month history of AUB and severe dysmenorrhoea had an LNG-IUD sited with effective symptom relief. Unfortunately, the device was expelled six months after insertion, and she responded poorly to other medical treatments. Transvaginal ultrasonography (TVUS) suggested posterior wall adenomyosis. Considering her relief of symptoms with the LNG-IUD and history of expulsion, the patient was counselled regarding suture-fixation of the LNG-IUD.

Results

She was followed-up at 6 months post insertion. The LNG-IUD was noted in the uterine cavity without displacement or expulsion.

Conclusion

Hysteroscopy-guided suture fixation of an LNG-IUD is a minimally invasive, effective option for patients with a history of expulsion of an IUD. However, further studies are required to establish the safety and efficacy of this approach. Learning Objective: To demonstrate LNG -IUD suture fixation technique using hysteroscopy for patients diagnosed with AUB and a history of device expulsion.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Condition tags

adenomyosisdysmenorrhea

Citation neighborhood (sparse)

Too few in-corpus citations on either side for a chart; here are the lists.

Cites (4)

Cited by (2)

References (9)

Cited by (2)

Source provenance

openalex
last seen: 2026-06-04T00:00:01.174412+00:00
License: CC0 · commercial use OK