Hysteroscopic Darwishscope Test Versus Bubble Flow Patency Test for Normal and Hydrosalpingeal Fallopian Tubes
article
OA: closed
CC0
⤵ 1 in-corpus citation
Abstract
Objectives: Currently available hysteroscopic tubal patency testing relies only on anatomical passage of air bubbles or flow of irrigating fluid and debris via tubal ostia. The aim of this study was to assess the reliability of a hysteroscopic proximal tubal bubble flow test and a peristalsis test separately or in combination (Darwishscope test) for detection of tubal patency in apparently normal fallopian tubes and hydrosalpinges as confirmed by laparoscopy. Materials and Methods: A prospective comparative cohort study was conducted at an endoscopy unit of a tertiary university hospital. The subjects were infertile women undergoing concurrent laparoscopy and hysteroscopy for infertility management. The patients were classified into group A (women with normal-caliber and patent fallopian tubes seen on laparoscopy) or group B (women with unilateral or bilateral distended and blocked distal ends of their fallopian tubes [hydrosalpinx] seen on laparoscopy). A combined hysteroscopic bubble flow test and proximal tubal peristalsis (Darwishscope test) were performed. The primary outcome was how many patients had positive combined bubble flow and proximal tubal peristalsis tests separately or in combination (Darwishscope test) in both apparently normal and hydrosalpingeal tubes. Feasibility of the procedure, access and any proximal tubal abnormalities were secondary outcome measures. Results: Among 115 infertile women, there was an insignificant difference between both groups regarding basic data except a significant increased history of pelvic inflammatory disease in group B. Endometriosis was reported in 20 (33.9%) and 24 (42.7%) cases in both groups, respectively. On hysteroscopy, the bubble flow test was positive in 106 tubes (89.8%) in group A and 56 (50%) tubes in group B after exclusion of unilateral patent tubes with a sensitivity of 84.8% (95% confidence interval [CI]: 73.0–92.8) and 88.1% (95% CI: 77.1–95.1) on the right and left sides, respectively. Tubal peristalsis was positive in 80 tubes (67.8%) in group A and in 13 tubes (14%) in group B after exclusion of unilateral patent tubes with higher specificity than the bubble flow test (57.1% [95% CI: 43.2–70.3] and 67.9% [95% CI: 54.0–79.7] versus 47.6% [95% CI: 32.0–63.6] and 29.8% [95% CI: 17.3–44.9] on the right and left sides, respectively). Use of the Darwishscope test resulted in a rise of specificity, a positive predictive value, a negative predictive value, and diagnostic accuracy on both sides, compared to either test alone in both normal and pathologic tubes. Conclusions: The bubble flow test is the most-sensitive test of patency of the proximal part of the fallopian tubes. A fallopian tube peristalsis physiologic patency test is more-specific than a bubble flow test. The Darwishscope test is superior to either test alone for assessing proximal tubal function, as it this is test the most-specific test of both anatomical and physiologic patency in normal and pathologic tubes with high diagnostic accuracy. (J GYNECOL SURG 38:49)
My notes (saved in your browser only)
Condition tags
Citation neighborhood (sparse)
Too few in-corpus citations on either side for a chart; here are the lists.
Cites (1)
Cited by (1)
References (22)
- Peristalsis and Antiperistalsis of the Human Fallopian Tube During the Menstrual Cycle1 via openalex
- W1568404174 via openalex
- W1976036868 via openalex
- W2017462067 via openalex
- W2025184948 via openalex
- W2059193663 via openalex
- W2074631551 via openalex
- W2108748538 via openalex
- W2156696205 via openalex
- W2169251526 via openalex
- W2338742070 via openalex
- W2588900036 via openalex
- W2740146242 via openalex
- W2745703490 via openalex
- W2763941358 via openalex
- W2782814266 via openalex
- W2922234916 via openalex
- W2948806961 via openalex
- W3046136291 via openalex
- W3104514933 via openalex
- W38056822 via openalex
- W4248728823 via openalex
Cited by (1)
Source provenance
- openalex
- last seen: 2026-06-04T00:00:01.174412+00:00
- unpaywall
- last seen: 2026-06-06T02:00:05.402940+00:00
License: CC0
· commercial use OK