Characterization of normal and polycystic ovaries using three-dimensional power Doppler ultrasonography.

OA: closed

Abstract

PurposeTo evaluate the characteristics of polycystic compared to normal ovaries using three-dimensional (3-D) power Doppler ultrasonography.MethodsWe recruited 42 volunteers, all of whom were commencing IVF treatment. Each patient was examined in the cycle preceeding the start of drug therapy during the late follicular phase. If eight or more subcapsular follicles of 2-8 mm in diameter in one two-dimensional (2-D) plane were detected in either of the ovaries, the patient was categorized as having polycystic ovaries (PCO); otherwise the ovaries were considered normal. The parameters examined were volume of the ovary, vascularization index (VI), flow index (FI), vascularization flow index (VFI), and mean greyness (MG). In addition, the ovary was arbitrarily divided into cortex and stroma, and thereafter volume, VI, FI, VFI, and MG were calculated for these two regions.ResultsTwenty-eight women had normal ovaries and 14 had PCO. The comparison between normal and PCO showed that as a group the PCO were larger, without any differences in VI, Fl, VFI, or MG. In patients with PCO, the right ovary was larger than the left one. In patients with normal ovaries, Fl was higher on the left side. Division into cortex and stroma revealed that there were no differences in cortical or stromal VI, FI, VFI, or MG between normal and PCO on either side.ConclusionsThe ovaries defined as polycystic were larger than normal ovaries, but there was no difference in the echogenicity of the stroma between polycystic and normal ovaries. We were also unable to demonstrate that the polycystic ovarian stroma was more vascularized than the stroma in the normal ovaries.
Full text 8,111 characters · extracted from oa-doi-fallback · 5 sections · click to expand

Abstract

Purpose : To evaluate the characteristics of polycystic compared to normal ovaries using three-dimensional (3-D) power Doppler ultrasonography.

Methods

We recruited 42 volunteers, all of whom were commencing IVF treatment. Each patient was examined in the cycle preceeding the start of drug therapy during the late follicular phase. If eight or more subcapsular follicles of 2–8 mm in diameter in one two-dimensional (2-D) plane were detected in either of the ovaries, the patient was categorized as having polycystic ovaries (PCO); otherwise the ovaries were considered normal. The parameters examined were volume of the ovary, vascularization index (VI), flow index (FI), vascularization flow index (VFI), and mean greyness (MG). In addition, the ovary was arbitrarily divided into cortex and stroma, and thereafter volume, VI, FI, VFI, and MG were calculated for these two regions.

Results

Twenty-eight women had normal ovaries and 14 had PCO. The comparison between normal and PCO showed that as a group the PCO were larger, without any differences in VI, FI, VFI, or MG. In patients with PCO, the right ovary was larger than the left one. In patients with normal ovaries, FI was higher on the left side. Division into cortex and stroma revealed that there were no differences in cortical or stromal VI, FI, VFI, or MG between normal and PCO on either side.

Conclusions

The ovaries defined as polycystic were larger than normal ovaries, but there was no difference in the echogenicity of the stroma between polycystic and normal ovaries. We were also unable to demonstrate that the polycystic ovarian stroma was more vascularized than the stroma in the normal ovaries. Similar content being viewed by others

References

Adams J, Franks S, Polson DW, Mason HD, Abdulwahid N, Tucker M, Morris DV, Price J, Jacobs HS: Multifollicular ovaries: Clinical and endocrine features and response to pulsatile gonadotropin releasing hormone. Lancet 1985;2:1375–1379 Adams J, Polson DW, Franks S: Prevalence of polycystic ovaries in women with anovulation and idiopathic hirsutism. Br Med J (Clin Res Ed) 1986;293:355–359 Homburg R: Polycystic ovary syndrome—From gynaecological curiosity to multisystem endocrinopathy. Hum Reprod 1996;11:29–39 Al-Took S, Watkin K, Tulandi T, Tan SL: Ovarian stromal echogenicity in women with clomiphene citrate-sensitive and clomiphene citrate-resistant polycystic ovary syndrome. Fertil Steril 1999;71:952–954 Atiomo WU, Pearson S, Shaw S, Prentice A, Dubbins P: Ultrasound criteria in the diagnosis of polycystic ovary syndrome (PCOS). Ultrasound Med Biol 2000;26:977–980 Kyei-Mensah A, Zaidi J, Campbell S: Ultrasound diagnosis of polycystic ovary syndrome. Baillieres Clin Endocrinol Metab 1996;10:249–262 Zaidi J, Campbell S, Pittrof R, Kyei-Mensah A, Shaker A, Jacobs HS, Tan SL: Ovarian stromal blood flow in women with polycystic ovaries—A possible new marker for diagnosis? Hum Reprod 1995;10:1992–1996 Aleem F, Predanic M: Transvaginal color Doppler determination of the ovarian and uterine blood flow characteristics in polycystic ovary disease. Fertil Steril 1996;65:510–516 Agrawal R, Sladkevicius P, Engmann L, Conway GS, Payne NN, Bekis J, Tan SL, Campbell S, Jacobs HS: Serum vascular endothelial growth factor concentrations and ovarian stromal blood flow are increased in women with polycystic ovaries. Hum Reprod 1998;13:651–655 Pinkas H, Mashiach R, Rabinerson D, Avrech OM, Royburt M, Rufas O, Meizner I, Ben-Rafael Z, Fisch B: Doppler parameters of uterine and ovarian stromal blood flow in women with polycystic ovary syndrome and normally ovulating women undergoing controlled ovarian stimulation. Ultrasound Obstet Gynecol 1998;12:197–200 Takahashi K, Okada M, Ozaki T, Uchida A, Yamasaki H, Kitao M: Transvaginal ultrasonographic morphology in polycystic ovarian syndrome. Gynecol Obstet Invest 1995;39:201–206 Fox R:Transvaginal ultrasound appearances of the ovary in normalwomenand hirsutewomenwith oligomenorrhoea.Aust N Z J Obstet Gynaecol 1999;39:63–68 Battaglia C, Regnani G, Artini PG, Giulini S, Genazzani AD, Genazzani AR, Volpe A: Polycystic ovary syndrome: A new ultrasonographic and color Doppler pattern. Gynecol Endocrinol 2000;14:417–424 Pairleitner H, Steiner H, Hasenoehrl G, Staudach A: Threedimensional power Doppler sonography: Imaging and quantifying blood flow and vascularization. Ultrasound Obstet Gynecol 1999;14:139–143 Cohen LS, Escobar PF, Scharm C, Glimco B, Fishman DA: Three-dimensional power Doppler ultrasound improves the diagnostic accuracy for ovarian cancer prediction. Gynecol Oncol 2001;82:40–48 Keberle M, Jenett M, Hahn D: Clinical trial on the accuracy of a freehand and sensor-independent three-dimensional power Doppler ultrasound system measuring diameters, volumes and vascularity of malignant primaries of the neck. Ultraschall Med 2001;22:91–95 Norman RJ, Hague WM, Masters SC, Wang XJ: Subjects with polycystic ovaries without hyperandrogenaemia exhibit similar disturbances in insulin and lipid profiles as those with polycystic ovary syndrome. Hum Reprod 1995;10:2258–2261 Agrawal R, Conway G, Sladkevicius P, Tan SL, Engmann L, Payne N, Bekir J, Campbell S, Jacobs H: Serum vascular endothelial growth factor and Doppler blood flow velocities in in vitro fertilization: Relevance to ovarian hyperstimulation syndrome and polycystic ovaries. Fertil Steril 1998;70:651–658 Pache TD, Hop WC, Wladimiroff JW, Schipper J, Fauser BC: Transvaginal sonography and abnormal ovarian appearance in menstrual cycle disturbances. Ultrasound Med Biol 1991;17:589–593 van Hooff MH, Voorhorst FJ, Kaptein MB, Hirasing RA, Koppenaal C, Schoemaker J: Polycystic ovaries in adolescents and the relationship with menstrual cycle patterns, luteinizing hormone, androgens, and insulin. Fertil Steril 2000;74: 49–58 Buckett WM, Bouzayen R, Watkin KL, Tulandi T, Tan SL: Ovarian stromal echogenicity in women with normal and polycystic ovaries. Hum Reprod 1999;14:618–621 Wu MH, Tang HH, Hsu CC, Wang ST, Huang KE: The role of three-dimensional ultrasonographic images in ovarian measurement. Fertil Steril 1998;69:1152–1155 Griffin IJ, Cole TJ, Duncan KA, Hollman AS, Donaldson MD: Pelvic ultrasound measurements in normal girls. Acta Paediatr 1995;84:536–543 Pan HA, Wu MH, Cheng YC, Li CH, Chang FM. Quantifi-cation of Doppler signal in polycystic ovary syndrome using three-dimensional power Doppler ultrasonography: A possible new marker for diagnosis. Hum Reprod 2002;17:201–206 Engmann L, Sladkevicius P, Agrawal R, Bekir J, Campbell S, Tan SL: The pattern of changes in ovarian stromal and uterine artery blood flow velocities during in vitro fertilization treatment and its relationship with outcome of the cycle. Ultrasound Obstet Gynecol 1999;13:26–33 Battaglia C, Artini P, D'Ambrogio G, Genazzani A, Genazzani A: The role of color Doppler imaging in the diagnosis of Journal of Assisted Reproduction and Genetics, Vol. 19, No. 12, December 2002 590 J¨arvel ¨ a, Mason, Sladkevicius, Kelly, Ojha, Campbell, and Nargund polycystic ovary syndrome. Am J Obstet Gynecol 1995;172:108–113 Sladkevicius P, Valentin L, Marsal K: Blood flow velocities in the uterine and ovarian arteries during normal menstrual cycle. Ultrasound Obstet Gynecol 1993;3:199–208 Tan S, Zaidi J, Campbell S, Doyle P, Collins W: Blood flow changes in the ovarian and uterine arteries during the normal menstrual cycle. Am J Obstet Gynecol 1996;175:625–631 Zaidi J, Jacobs H, Campbell S, Tan SL: Blood flow changes in the ovarian and uterine arteries in women with polycystic ovary syndrome who respond to clomiphene citrate: Correlation with serum hormone concentrations. Ultrasound Obstet Gynecol 1998;12:188–196 Author information Authors and Affiliations Corresponding author Rights and permissions About this article Cite this article Järvelä, I.Y., Mason, H.D., Sladkevicius, P. et al. Characterization of Normal and Polycystic Ovaries Using Three-Dimensional Power Doppler Ultrasonography. J Assist Reprod Genet 19, 582–590 (2002). https://doi.org/10.1023/A:1021267200316 Issue date: DOI: https://doi.org/10.1023/A:1021267200316

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-07-29T06:27:48.050232+00:00
unpaywall
last seen: 2026-06-06T02:00:05.402940+00:00