- 1 United Nations .World Contraceptive Use 2007. New York, NY; United Nations Publications 2007
- 2 Duramed Pharmaceuticals .Prescribing Information ParaGard T380A. 2006
- 3 Bayer HealthCare Pharmaceuticals .Mirena Physician Prescribing Information. 2008
- 4 Rivera R, Yacobson I, Grimes D. The mechanism of action of hormonal contraceptives and intrauterine contraceptive devices. Am J Obstet Gynecol. 1999; 181(5 Pt 1) 1263-1269
- 5 Stanford J B, Mikolajczyk R T. Mechanisms of action of intrauterine devices: update and estimation of postfertilization effects. Am J Obstet Gynecol. 2002; 187(6) 1699-1708
- 6 Lähteenmäki P, Rauramo I, Backman T. The levonorgestrel intrauterine system in contraception. Steroids. 2000; 65(10-11) 693-697
- 7 Barbosa I, Bakos O, Olsson S E, Odlind V, Johansson E D. Ovarian function during use of a levonorgestrel-releasing IUD. Contraception. 1990; 42(1) 51-66
- 8 Bahamondes L, Hidalgo M, Petta C A, Diaz J, Espejo-Arce X, Monteiro-Dantas C. Enlarged ovarian follicles in users of a levonorgestrel-releasing intrauterine system and contraceptive implant. J Reprod Med. 2003; 48(8) 637-640
- 9 United Nations Development Programme . Long-term reversible contraception. Twelve years of experience with the TCu380A and TCu220C. Contraception. 1997; 56(6) 341-352
- 10 Backman T, Rauramo I, Huhtala S, Koskenvuo M. Pregnancy during the use of levonorgestrel intrauterine system. Am J Obstet Gynecol. 2004; 190(1) 50-54
- 11 Peterson H B, Xia Z, Hughes J M, Wilcox L S, Tylor L R, Trussell J. The risk of pregnancy after tubal sterilization: findings from the U.S. Collaborative Review of Sterilization. Am J Obstet Gynecol. 1996; 174(4) 1161-1168, discussion 1168–1170
- 12 Trussell J, Lalla A M, Doan Q V, Reyes E, Pinto L, Gricar J. Cost effectiveness of contraceptives in the United States. Contraception. 2009; 79(1) 5-14
- 13 Ellertson C, Trussell J, Stewart F, Koenig J, Raymond E G, Shochet T. Emergency contraception. Semin Reprod Med. 2001; 19(4) 323-330
- 14 Milsom I, Andersson K, Jonasson K, Lindstedt G, Rybo G. The influence of the Gyne-T 380S IUD on menstrual blood loss and iron status. Contraception. 1995; 52(3) 175-179
- 15 World Health Organization . The TCu380A, TCu220C, multiload 250 and nova T IUDs at 3, 5 and 7 years of use—results from three randomized multicentre trials. Contraception. 1990; 42(2) 141-158
- 16 Hidalgo M, Bahamondes L, Perrotti M, Diaz J, Dantas-Monteiro C, Petta C. Bleeding patterns and clinical performance of the levonorgestrel-releasing intrauterine system (Mirena) up to two years. Contraception. 2002; 65(2) 129-132
- 17 Zhang J, Feldblum P J, Chi I C, Farr M G. Risk factors for copper T IUD expulsion: an epidemiologic analysis. Contraception. 1992; 46(5) 427-433
- 18 Bahamondes L, Díaz J, Marchi N M, Petta C A, Cristofoletti M L, Gomez G. Performance of copper intrauterine devices when inserted after an expulsion. Hum Reprod. 1995; 10(11) 2917-2918
- 19 Harrison-Woolrych M, Ashton J, Coulter D. Uterine perforation on intrauterine device insertion: is the incidence higher than previously reported?. Contraception. 2003; 67(1) 53-56
- 20 World Health Organization .Selected Practice Recommendations for Contraceptive Use [update]. Geneva, Switzerland; World Health Organization 2004
- 21 Farley T MM, Rosenberg M J, Rowe P J, Chen J H, Meirik O. Intrauterine devices and pelvic inflammatory disease: an international perspective. Lancet. 1992; 339(8796) 785-788
- 22 Grimes D A, Schulz K F. Prophylactic antibiotics for intrauterine device insertion: a metaanalysis of the randomized controlled trials. Contraception. 1999; 60(2) 57-63
- 23 Andersson K, Odlind V, Rybo G. Levonorgestrel-releasing and copper-releasing (Nova T) IUDs during five years of use: a randomized comparative trial. Contraception. 1994; 49(1) 56-72
- 24 Pakarinen P, Toivonen J, Luukkainen T, Pakarinen P, Toivonen J, Luukkainen T. Randomized comparison of levonorgestrel- and copper-releasing intrauterine systems immediately after abortion, with 5 years' follow-up. Contraception. 2003; 68(1) 31-34
- 25 Anonymous . IUD insertion following termination of pregnancy: a clinical trial of the TCu 220C, Lippes loop D, and copper 7. Stud Fam Plann. 1983; 14(4) 99-108
- 26 Drey E A, Reeves M F, Ogawa D D, Sokoloff A, Darney P D, Steinauer J E. Insertion of intrauterine contraceptives immediately following first- and second-trimester abortions. Contraception. 2009; 79(5) 397-402
- 27 Goodman S, Hendlish S K, Benedict C, Reeves M F, Pera-Floyd M, Foster-Rosales A. Increasing intrauterine contraception use by reducing barriers to post-abortal and interval insertion. Contraception. 2008; 78(2) 136-142
- 28 Grimes D, Schulz K, van Vliet H, Stanwood N. Immediate post-partum insertion of intrauterine devices: a Cochrane review. Hum Reprod. 2002; 17(3) 549-554
- 29 Çelen S, Möröy P, Sucak A, Aktulay A, Danişman N. Clinical outcomes of early postplacental insertion of intrauterine contraceptive devices. Contraception. 2004; 69(4) 279-282
- 30 Eroğlu K, Akkuzu G, Vural G et al.. Comparison of efficacy and complications of IUD insertion in immediate postplacental/early postpartum period with interval period: 1 year follow-up. Contraception. 2006; 74(5) 376-381
- 31 Hayes J L, Cwiak C, Goedken P, Zieman M. A pilot clinical trial of ultrasound-guided postplacental insertion of a levonorgestrel intrauterine device. Contraception. 2007; 76(4) 292-296
- 32 Hubacher D. Copper intrauterine device use by nulliparous women: review of side effects. Contraception. 2007; 75(6, suppl) S8-S11
- 33 Sivin I, Stern J. Long-acting, more effective copper T IUDs: a summary of U.S. experience, 1970–75. Stud Fam Plann. 1979; 10(10) 263-281
- 34 Veldhuis H M, Vos A G, Lagro-Janssen A L, Lagro-Janssen A LM. Complications of the intrauterine device in nulliparous and parous women. Eur J Gen Pract. 2004; 10(3) 82-87
- 35 Deans E I, Grimes D A. Intrauterine devices for adolescents: a systematic review. Contraception. 2009; 79(6) 418-423
- 36 Paterson H, Ashton J, Harrison-Woolrych M, Paterson H, Ashton J, Harrison-Woolrych M. A nationwide cohort study of the use of the levonorgestrel intrauterine device in New Zealand adolescents. Contraception. 2009; 79(6) 433-438
- 37 Morrison C S, Sekadde-Kigondu C, Sinei S K, Weiner D H, Kwok C, Kokonya D. Is the intrauterine device appropriate contraception for HIV-1-infected women?. BJOG. 2001; 108(8) 784-790
- 38 Stringer E M, Kaseba C, Levy J et al.. A randomized trial of the intrauterine contraceptive device vs hormonal contraception in women who are infected with the human immunodeficiency virus. Am J Obstet Gynecol. 2007; 197(2) 141-148
- 39 Heikinheimo O, Lehtovirta P, Suni J, Paavonen J. The levonorgestrel-releasing intrauterine system (LNG-IUS) in HIV-infected women—effects on bleeding patterns, ovarian function and genital shedding of HIV. Hum Reprod. 2006; 21(11) 2857-2861
- 40 Milsom I, Andersson K, Andersch B, Rybo G. A comparison of flurbiprofen, tranexamic acid, and a levonorgestrel-releasing intrauterine contraceptive device in the treatment of idiopathic menorrhagia. Am J Obstet Gynecol. 1991; 164(3) 879-883
- 41 Irvine G A, Campbell-Brown M B, Lumsden M A, Heikkila A, Walker J J, Cameron I T. Randomized comparative trial of the levonorgestrel intrauterine system and norethisterone for treatment of idiopathic menorrhagia. Br J Obstet Gynaecol. 1998; 105(6) 592-598
- 42 Hurskainen R, Teperi J, Rissanen P et al.. Clinical outcomes and costs with the levonorgestrel-releasing intrauterine system or hysterectomy for treatment of menorrhagia: randomized trial 5-year follow-up. JAMA. 2004; 291(12) 1456-1463
- 43 Andersson K, Mattsson L A, Rybo G, Stadberg E. Intrauterine release of levonorgestrel—a new way of adding progestogen in hormone replacement therapy. Obstet Gynecol. 1992; 79(6) 963-967
- 44 Boon J, Scholten P C, Oldenhave A, Heintz A P. Continuous intrauterine compared with cyclic oral progestin administration in perimenopausal HRT. Maturitas. 2003; 46(1) 69-77
- 45 Raudaskoski T, Tapanainen J, Tomás E et al.. Intrauterine 10 microg and 20 microg levonorgestrel systems in postmenopausal women receiving oral oestrogen replacement therapy: clinical, endometrial and metabolic response. BJOG. 2002; 109(2) 136-144
- 46 Petta C A, Ferriani R A, Abrao M S et al.. Randomized clinical trial of a levonorgestrel-releasing intrauterine system and a depot GnRH analogue for the treatment of chronic pelvic pain in women with endometriosis. Hum Reprod. 2005; 20(7) 1993-1998
- 47 Vercellini P, Frontino G, De Giorgi O, Aimi G, Zaina B, Crosignani P G. Comparison of a levonorgestrel-releasing intrauterine device versus expectant management after conservative surgery for symptomatic endometriosis: a pilot study. Fertil Steril. 2003; 80(2) 305-309
- 48 Sheng J, Zhang W Y, Zhang J P, Lu D. The LNG-IUS study on adenomyosis: a 3-year follow-up study on the efficacy and side effects of the use of levonorgestrel intrauterine system for the treatment of dysmenorrhea associated with adenomyosis. Contraception. 2009; 79(3) 189-193
- 49 Lockhat F B, Emembolu J O, Konje J C, Lockhat F B, Emembolu J O, Konje J C. The efficacy, side-effects and continuation rates in women with symptomatic endometriosis undergoing treatment with an intra-uterine administered progestogen (levonorgestrel): a 3 year follow-up. Hum Reprod. 2005; 20(3) 789-793
Noa'a ShimoniM.D.
Columbia University Medical Center, Department of Obstetrics and Gynecology
622 W. 168th St., New York, NY 10032
Email:
[email protected]