Enhancement of ovarian tumor classification by improved reproducibility in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry of serum glycans
other
OA: closed
public-domain-us
AI-generated summary
An optimized MALDI-TOF MS protocol for serum N-glycan profiling improved reproducibility and classification accuracy for borderline ovarian tumors compared to CA-125, suggesting potential for early-stage ovarian cancer screening.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
Abstract
The serum N-glycome is a promising source of biomarker discovery. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) profiling of serum N-glycans was attempted for differentiating borderline ovarian tumor from benign cases, for which a low data spread is essential. An experimental protocol using matrix-prespotted MALDI plates and fast vacuum drying of the loaded N-glycan samples was developed, thereby minimizing the intensity variations in the replicates to an average relative standard deviation (RSD) of 3.96% for the highest N-glycan peak (m/z 1485.53) of the Sigma-Aldrich serum standard. When applied to sera of ovarian tumors, this procedure exhibited an average RSD of 5.74% for m/z 1485.53 and of 7.28% for all MS peaks. This improved reproducibility combined with the OVA-Beyond(®) screening software resulted in 75.1% and 79.4% correct classification for benign and borderline tumor samples, respectively, while the classification rates by the conventional ovarian tumor marker CA-125 were 54.4% and 53.1%, respectively. Both true positive rate and true negative rate fluctuated with small numbers of markers and converged as the number of markers increased. Cross-validations were performed in comparison with CA-125. These results suggest that our optimized process for MALDI-TOF MS of the serum glycome has a great potential for the screening of early stage ovarian cancer.
My notes (saved in your browser only)
Condition tags
MeSH descriptors
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-08-23T09:30:01.253652+00:00
- pubmed
- last seen: 2026-05-13T22:18:53.335890+00:00
- unpaywall
- last seen: 2026-08-27T06:26:25.619941+00:00
License: public-domain-us
· commercial use OK
· attribution required
Courtesy of the U.S. National Library of Medicine
Courtesy of the U.S. National Library of Medicine