Reference
manual for image biomarker studies [11].
Radiomic features were shown to reflect cancer biology in terms of histologic
type [12], overall and progression-free survival [12–14], probability of recurrence [15],
activity of biological pathways [12,16], human papillomavirus infection [17], probability
lymph node [18] or distant metastases [ 19], CD8 cells infiltration [20]. Some studies
extended radiomic analysis outside tumor volume, including also peritumoral regions
for prediction of patients’ survival [21] or adjuvant chemotherapy [22]. Similarly, lymph
nodes were sometimes considered as ROI in studies that aimed at identifying lymph
nodes metastases [23,24]. Some radiomic NTCP models based on computed tomography
(CT) were developed, for instance for prediction of xerostomia after head-and-neck
cancer radiotherapy [25,26], radiation-induced pneumonitis [27]. Alternatively, radiomic
features for radiation-induced NTCP models could be calculated in 3D dose distribution
that was successfully done for cervical cancer [28], prostate cancer [29] and lung cancer
[30]. Given the very good performance of some NTCP models in predicting RIHT in
patients with OPC, the question whether there would be an added benefit of an in depth
radiomic analysis was unresolved and thus we decided to apply CT-based radiomics in
this group of patients and compare predictive performance with the available models
based on dosimetric and clinical features.
2. Materials and Methods
2.1. Patients and CT images
The studied cohort was a subgroup of patients included in previous study on
validation of NTCP models for radiation-induced hypothyroidism by Nowicka et al. [7],
recruited between 01.05.2016 and 31.12.2018 and followed up until 02.2020. In addition to
already collected clinical data, for this study we retrieved CT images from radiotherapy
planning with thyroid glands retrospectively contoured by two experienced radiation
oncologists according to the guidelines for organs at risk (OARs), as described previously.
Patients for whom the CT image was unavailable, thyroid contour was missing or thyroid
region contained CT artifacts, were excluded. Finally, among 108 patients recruited in
3 centers 98 had complete data and were included in this study (38 from center A -
Copernicus Regional Specialist Hospital in Lodz, Poland; 12 from center B - Radom
Oncology Centre and Maria Sklodowska-Curie National Research Institute of Oncology,
Radom, Poland and 48 from center C - Radiotherapy Department, Maria Sklodowska-
Curie National Research Institute of Oncology — branch in Gliwice, Poland); selection
of cases is summarized in Fig. 1A.
All patients underwent intensity-modulated radiation therapy (IMRT) of OPC be-
fore which their thyroid function was normal. After RT, they were monitored for a
median of 28 months on average (median). During this follow-up period, 27 patients
developed hypothyroidism. To avoid bias, laboratory assessment, contouring, out-
come assessments, statistical and radiomic analysis were performed by independent
researchers. Details of treatment protocol were described previously [7].
For all 98 patients, CT images paired with RT plans and anatomical structure
contouring files were retrieved from PACS of treating centers. All images were stored
in DICOM format in CT and RTSTRUCT modalities; however, some differences in
acquisition protocol were identified. First, each center used a different CT scanner (center
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
3 of 18
A: Somatom Sensation Open, Siemens; center B: Optima CT580 RT, GE Healthcare; center
C: SOMATOM Definition AS and Somatom Sensation Open, Siemens). In each center,
slice thickness and pixel spacing were selected by radiotherapist and radiologist so
that images were sufficient for treatment planning. Summary of selected settings in
each center is presented in Table 1 and anonymized raw patients data are in Table S1 in
supplementary material.
The study was approved by the Bioethics Committee of the Medical University of
Lodz (KE/7/10, RNN/65/18).
Table 1. Patient, disease and CT images characteristics.
Center A (n=38) Center B (n=12) Center C (n=48)
RIHT NO YES NO YES NO YES
Sex Female 7 7 1 1 5 2
Male 21 3 8 2 29 12
Age Median 62.0 60.0 61.0 57.0 57.5 58.0
IQR 57.0-66.2 56.8-61.8 60.0-68.0 55.5-60.5 53.0-62.0 52.2-66.5
Stage I-II 6 1 2 0 12 1
III-IV 22 9 7 3 22 13
Mean thyroid dose, Dmean (Gy) Median 54.8 57 55.2 57.3 47.2 52.5
IQR 51.9-56.3 52.7-59.3 53.5-56.3 56.2-58.4 43.8-49.5 49.7-56.2
Minimal thyroid dose, Dmin (Gy) Median 42.5 46.5 43 51.8 30.9 44.3
IQR 29.1-46.6 43.3-47.5 41.1-48.2 50.1-54.3 24.6-39.0 32.7-46.9
Median thyroid dose, D50 (Gy) Median 55.0 55.5 54.5 58.5 47.0 52.2
IQR 53.7-56.3 52.9-58.7 53.9-54.9 57.2-59.0 43.8-50.4 50.5-56.4
Maximal thyroid dose, Dmax (Gy) Median 62.5 69.4 61.7 61.6 60.2 65.1
IQR 57.6-70.1 63.3-71.9 60.8-62.1 59.6-61.8 52.6-68.0 53.6-72.2
Thyroid volume (ml) Median 21.7 11.8 29 12.6 19.1 10.6
IQR 19.0-32.9 7.7-13.9 21.7-37.4 10.6-14.0 14.6-27.6 8.3-13.3
Baseline fT4 (pg/mL) Median 6.5 6.1 9.3 8.2 7.2 8.1
IQR 5.3-7.4 5.1-7.6 8.0-10.1 7.7-10.7 6.3-8.4 7.9-9.9
Baseline TSH (mIU/L) Median 0.5 1.3 0.7 0.4 0.7 1.1
IQR 0.3-0.8 0.8-1.7 0.6-1.2 0.4-0.7 0.5-1.5 0.6-1.2
Mean pituitary dose (Gy) Median 4.0 3.8 4.0 3.8 3.8 3.7
IQR 3.0-4.5 3.0-5.3 3.2-4.8 3.6-3.8 3.0-4.4 3.0-4.8
Time to follow-up (months) Median 29.5 15 22 13 38 19
IQR 26.0-37.2 14.0-15.8 21.0-24.0 12.0-13.5 31.2-41.0 16.0-21.0
Pixel spacing (mm2)
0.98x0.98 25 9 0 0 26 11
1.07x1.07 1 0 0 0 3 3
1.09x1.09 0 0 0 0 1 0
1.11x1.11 0 0 0 0 1 0
1.13x1.13 0 0 0 0 1 0
1.17x1.17 0 0 0 0 1 0
1.27x1.27 1 0 9 3 1 0
1.56x1.56 1 1 0 0 0 0
Slice thickness (mm)
1.5 1 0 0 0 0 0
2 1 1 0 0 2 1
2.5 0 0 9 3 0 0
3 24 9 0 0 26 9
4 0 0 0 0 6 4
5 2 0 0 0 0 0
2.2. Image preprocessing and radiomic features calculation
Due to diversity of pixel spacing and slice thicknesses, all images and thyroid
masks (generated from contours using dcmrtstruct2nii library [ 31]) were resampled
to 1x1x1mm3 isotropic voxels. Then we used PyRadiomics v3.0 [ 32] to calculate ra-
diomic features that in the applied version of the library included: 14 shape features, 18
first order statistics, 24 gray level cooccurrence matrix-based (GLCM) features, 16 gray
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
4 of 18
level run length matrix-based (GLRLM) features, 16 gray level size zone matrix-based
(GLSZM) features, 5 neighborhood gray tone difference matrix-based (NGTDM) features,
14 gray level dependence matrix-based (GLDM) features (full list of features in Appendix
A). Radiomic features were extracted from original images and from their filtered ver-
sions, applying all filters available in PyRadiomics feature extractor: square, square root,
logarithm, gradient, exponential and 8 wavelet decomposition filters. Default values
of PyRadiomics feature extractor settings were used, including filtration parameters.
Resegmentation was not applied. In total, 1316 features were calculated for each image
(14 shapes features extracted from image mask, 93 intensity-based features for original
images and 13 filtered ones).
The processing of images and NTCP models derivation are summarized in Fig. 1B,
while raw radiomic features values are reported in Table S2.
Figure 1. Summary of patients’ selection and data subsets (A). Outline of the study from image segmentation to NTPC
model derivation (B).
2.3. Stability assessment
The purpose of stability analysis was to identify features that were unaffected
(or affected only slightly) by minor differenced in contouring of thyroid glands. As
the segmentations by multiple radiotherapists or radiologists were not available, we
decided to perform a simulation study. We modelled inaccuracies of contouring as affine
deformations of thyroid mask, consisting of:
• 3 translations by up to 1 mm in either direction along each of the 3 main axes,
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
5 of 18
• 3 rotations by up to 2° in either direction around each of the 3 main axes,
• 3 zooms by up to 2% of either dimension along each of the 3 main axes.
We generated 100 such transformations by randomly choosing order and param-
eters of the above 9 operations. Then, we applied every transformation to all thyroid
masks in our image data set and used the transformed masks to calculate new sets of
radiomic features.
Inter-class correlation coefficient (ICC) served as a measure of agreement between
original features (calculated using unchanged mask) and those calculated using each of
100 transformed masks. Later, 100 ICC values obtained for different transformed masks
were averaged to give single measure of stability for each feature. Stability was classified
as excellent when mean ICC exceeded 0.9, good (ICC between 0.75 and 0.9), moderate
(ICC between 0.5 and 0.75) or poor (ICC not exceeding 0.5).
2.4. Feature preprocessing and splitting data set
Raw feature values were firstly scaled to a [-1,1] range, then subjected to Yeo–Johnson
transformation [33] and scaled to [-1,1] range once again to facilitate machine learn-
ing model derivation. As average values and distributions of features values varied
across the samples (Fig. S1) we normalized them dividing each value by sample mean.
While performing normalization, we followed the reasoning common for other high-
throughput studies (transcriptomics, proteomics) that usually only minority of features
should be expected to differ between conditions, thus the distribution of all feature
values should not differ significantly between samples.
We observed that even after normalization, we could still observe batch effect
related to clinics that performed CT scans (Fig. S2). Thus, to account for this and check
the impact of batch on NTCP model performance, we decided to implement different
variants of data preprocessing and splitting:
• Variant I without batch effect correction, later referred to as Variant Ia: center A as
training set, centers B and C as validation set as shown in Fig. 1A.
• Variant I with batch effect removed by ComBat [34], referred to also as Variant Ib:
center A as training set, centers B and C as validation set.
• Variant II: no batch effect removal, but data from three centers were joined and sub-
sequently divided into training and validation sets (Fig. 1A). Training set contained
38 cases to match the size of center A data set so that both variants of splitting data
are comparable.
2.5. Feature filtration
Due to the large number of features, we decided to filter them before derivation of
NTCP models. First, only features with excellent or good stability were considered as
candidates for NTCP model predictors. We used ICC classes from center A for filtration
in Variant I and, analogously ICC classes from training set for Variant II.
Then, in order to retain only features that actually differentiate patient with and
without RIHT in follow-up, t-tests were performed to compare values of each stable
feature between these group. Benjamini-Hochberg correction was applied to p-values
to control false discovery rate (FDR) in this large set of comparisons. Next, hierarchical
clustering of features was performed with 1 – r (correlation coefficient) as distance mea-
sure and average linkage to identify groups of highly correlated features. These groups
of features were extracted by setting a threshold of 0.3 to distances in the dendrogram.
From each such group we retained a single feature with lowest FDR-corrected p-value
(later referred to as FDR) on the condition that this FDR did not exceed 0.1. Additionally,
we kept all features with FDR<0.01 even if they were correlated with others. This short-
ened list of features was the basis for models’ training that included final model-based
feature selection.
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
6 of 18
2.6. Model training and evaluation
Model training was performed with the use of scikit-learn Python library [ 35].
Model architectures considered in our analysis included: logistic regression, multilayer
perceptron (MLP), k nearest neighbors classifier, support vector classifier, decision tree,
random forest, AdaBoost classifier, Gaussian process classifier, Gaussian Naive Bayes
classifier, Quadratic discriminant analysis. Whenever possible (in logistic regression,
support vector classifiers, decision trees and random forest) two methods of weighting
cases during training were applied: 1) equal weights of all cases 2) weights inversely
proportional to classes’ frequencies to account for imbalanced data set with less than
1/3 of cases in RIHT group. Full list of tested model parameters is collected in Table S3.
Models were derived using three feature sets: 1) only clinical and dosimetric
features (clinical model), 2) only radiomic features (radiomic model), 3) radiomic, clinical
and dosimetric features (radiomic+clinical model). Final set of input features for each
model was determined by forward method of Sequential Feature Selector from mlxtend
library [36]. Feature selector used area under the ROC curve (AUC) as a measure of
models’ performance and was allowed to choose from 2 to 5 features.
All models were first derived using training data and then their performance
was tested on validation data. AUC, accuracy, sensitivity, specificity and F-score were
calculated for each model. The analysis was performed for Variants Ia, Ib and II of
clinical and radiomic features derivation. Models with the highest F-score were selected
for each variant of analysis and input feature set. Finally, ensembles of best clinical and
radiomic models were considered that combined them in following ways:
• logical conjunction (AND): positive prediction only when both models predicted
RIHT,
• logical disjunction (OR): positive prediction when any of the two models predicted
RIHT,
• averaged probability (PROBA): probability (raw output) of two models were aver-
aged and new decision threshold selected using ROC curve for training set.
3. Results
3.1. Feature stability analysis
Results
of feature stability analysis differed slightly between variant I and II. In
variant I, where all images were acquired in the same center, we identified more features
as highly stable (ICC>0.9) than in variant II (721, Fig. 2A vs 621 features, Fig. 2B). In line
with this observation, lowest stability class was assigned to 211 in variant II and only to
138 features in variant I (stability analysis was performed before batch correction, thus at
this stage variant Ia and Ib are not distinguished). Independently of the variant, all shape
features were excellently stable even though our test consisted essentially in disturbing
thyroid mask shape. Excellent or good stability was observed for majority of first order,
GLCM, GLRLM, and GLDM features, while for GLSZM and NGTDM the fraction of
unstable features was higher. In majority, stable features overlapped between variants I
and II (Fig. 2C). Stability of features depended also on the applied filter (Fig.2D), with
exponential and gradient filter ensuring on average higher stability than square, square
root, logarithm and some wavelet filters.
In further analysis, we included all features with excellent and good stability: 926
in variant I and 869 in variant II. Stability classes for all features are reported in Table S4.
3.2. Feature processing and filtration
Before filtration, features were scaled, normalized (Fig. S1) and in variant Ib batch
effect was corrected (Fig. 2S). First stage of filtration consisted of exclusion of features
that in univariate analysis did not differentiate patients who did or did not develop
RIHT (detailed results of this analysis in Table S5). It resulted in selection of 165 radiomic
features in variant I and 166 in variant II, among which 153 were common to both
variants (Fig. 3A). Having a limited number of patients, we decided to reduce these
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
7 of 18
Figure 2. Results of feature stability assessment. Number of features in each group classified to different stability categories
for variant I (A) and II (B). Overlap of features with at least good stability between variant I and II (C). Average stability of
all radiomic features with respect to applied image filter (D, shown mean with 95% confidence interval).n (B).
numbers further before model development by elimination of highly correlated features.
Selection of representatives from each group of such related variables left 67 features
in variant Ia, 68 in variant Ib and 66 in variant II (lists of features in Table S6). Again,
the overlap between variants, consisting of 61 radiomic features, greatly outnumbered
distinct variables for each variant (Fig. 3C). At both stages of filtration, features from
original image and the one with exponential filter applied were preferred over other
groups (Fig. 3BD).
3.3. Models
The training of all the considered models on the reduced set of features and their
validation resulted in selection of top 9 models, one for each variant and a feature set.
Their names, along with the features they were built upon, are presented in Table 2,
while details of all analysed models can be found in Table S7.
For all the variants, when considering models derived only with clinical features,
Gaussian process classifier was chosen. Likewise, the same set of features was selected,
i.e., mean of thyroid dose, median of thyroid dose and volume of the thyroid. For
radiomic and clinical+radiomic feature sets, the selected models were: logistic regression
without regularization, with equal class weights and excluded intercept for variant Ia
and multilayer perceptron with 4 hidden neurons for variants Ib and II. For those feature
sets, selected features were more diverse.
In all variants of analysis, radiomic models performed similarly to clinical models
(Fig. 4A-C); comparisons of ROC AUC by DeLong test never showed superiority of mod-
els using radiomic features vs clinical/dosimetric model (Table3. Slight improvement of
radiomic models is observed after batch effect correction (variant Ib). The statistical mea-
sures (sensitivity, specificity, accuracy and f-score) for each of the selected models and the
ensembles of clinical and radiomic models were calculated (Fig. 4D-I). Radiomic+clinical
model was not included in ensembles, because it contained a very similar feature set
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
8 of 18
Figure 3. Features with FDR<0.1 in univariate analysis grouped by radiomics category (A) and by image filter (B). Features
selected for model grouped by radiomics category (C) and by image filter (D).
to radiomic and clinical models taken together. Based on those measures, we picked
clinical, radiomic and OR models for the comparison with the external NTCP models for
radiation-induced hypothyroidism [8,9,37–39].
Table 2. Model architectures and features selected for each of the variants and feature sets.
V ARIANT Ia V ARIANT Ib V ARIANT II
model features model features model features
clinical
(same for Ia and Ib) GPC
Dmean
D50
Vthyroid
GPC
Dmean
D50
Vthyroid
GPC
Dmean
D50
Vthyroid
radiomic LR E
wavelet HHH GLSZM
zone percentage
logarithm NGTDM
coarseness
MLP4
original NGTDM
coarseness
wavelet LLL NGTDM
coarseness
exponential GLDM
small dependence
low gray level emphasis
logarithm NGTDM
coarseness
MLP4
exponential GLDM
small dependence
low gray level emphasis
logarithm NGTDM
coarseness
clinical+radiomic LR E
sex
original shape
least axis length
exponential GLRLM
run percentage
exponential GLDM
small dependence
low gray level emphasis
logarithm NGTDM
coarseness
MLP4
original NGTDM
coarseness
wavelet LLL NGTDM
coarseness
exponential GLDM
small dependence
low gray level emphasis
logarithm NGTDM
coarseness
MLP4
sex
original shape
least axis length
exponential GLRLM
run percentage
exponential GLDM
small dependence
low gray level emphasis
logarithm NGTDM
coarseness
GPC – Gaussian process classifier, LRE – logistic regression with equal cases weights,
MLP4 – MLP network with 4 neurons in single hidden layer
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
9 of 18
Table 3. Comparison between best models with and without radiomic features.
V ARIANT Ia V ARIANT Ib V ARIANT II
Model AUC ± SE p AUC ± SE p AUC ± SE p
clinical 0.90±0.07 - 0.90±0.07 - 0.95±0.05 -
radiomic 0.89±0.07 0.9196 0.94±0.05 0.6471 0.91±0.07 0.6263
radiomic+clinical 0.85±0.08 0.6386 0.94±0.05 0.6471 0.55±0.12 0.0008
PROBA 0.90±0.07 1.0000 0.95±0.05 0.5549 0.93±0.06 0.7940
p-values for comparison of each model with radiomic features vs clinical model
Compared with previous examples (Fig. 5), our models tend to be slightly less
sensitive, but more specific and accurate. Models by Cella et al. and Vogelious et al.
significantly overestimate risk of RIHT, declaring all or almost all patients as having
high risk of this complication. The model by Ronjom et al. seemed comparable to our
models.
Figure 4. AUC ROC of the selected models (clinical, radiomic, radiomic+clinical) and their ensembles for the training set (A,
B, C). Comparison of statistical measures for the selected model architectures of the considered feature sets and ensembles
of those models: training (D, E, F) and validation (G, H, I).
Radiomic features included in the final models came from original, logarithm,
exponential and wavelet (LLL, HHH) images. Majority of these features measured
nonuniformity of the thyroid region (e.g. coarseness, zone percentage) and were higher
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
10 of 18
in patients who developed RIHT (Fig. 6). The only feature lower in these patients was
least axis length of thyroid (Fig. S3).
4. Discussion
Here, using data from 98 patients with OPC treated with definite RT, we identified
radiomic features predicting the occurrence of RIHT in 2-year follow-up and contrasted
our radiomic-based model with published NTCP models based on clinical and dosimetric
parameters. Our model performed comparably to models published Rønjom et al.[ 8]
and by Boomsma et al. [ 9] and better than three other external models [ 37–39]. Since
predictions based on CT-derived radiomic features are agnostic to dose distribution,
they reflect the baseline susceptibility of individual thyroid glands to damage inflicted
by radiation doses typical for head and neck cancer RT. They may be therefore leveraged
to identify patients in whom close attention should be paid to minimize radiation to the
thyroid and the risk of RIHT; alternatively, dosimetric/clinical and radiomic models can
be combined to improve prediction accuracy.
Most features in our radiomic model were calculated in filtered CT images and
described non-uniformity or coarseness of thyroid region, sometimes emphasizing
low grey levels. Invariably higher values of these features, indicating greater non-
homogeneity, especially of darker (lower Hounsfield units) regions of thyroid, were
characteristic for patients who later developed RIHT.
Differences in performance between our models and external ones as well as those
between different external models likely stem from differences in patient cohort charac-
teristics and chosen treatment protocols, which has already been discussed in details in
previous study by Nowicka et al. [7] that used data from the same cohort of patients.
An important contribution of our study is analytical pipeline that adds to the recom-
mendations from first reference manual for image biomarker studies [11] and Radiomic
Quality Score (RQS) [40]. Addressing criteria from RQS, we reported imaging protocols
from participating institutions and verified the stability of features by segmentation
perturbation, reducing the number of features and applying multiple comparisons cor-
rection. Our simulation study showed that some features are unstable with respect to
inaccuracies in thyroid contouring; however, we identified a subset of relatively stable
features, corresponding with the results of study on robustness of radiomic features by
Zwanenburg et al. [41]. Then, we scaled and normalized the features and performed
batch effect correction in one variant of the analysis. This pipeline may be reused and ex-
tended for similar projects requiring combining data from many institutions or imaging
machines.
We included non-radiomic patient characteristics in the study, reported models’
quality statistics and validated models. Patients were recruited prospectively in 3 clinics
for the study by Nowicka et al. with the same endpoint of RIHT [7], however radiomic
analysis was included in the protocol at the later stage. In the place of validation against
“golden standard”, that is not established for prediction of RIHT, we compared our
models with those by other authors. As reported by reviews of radiomic studies [42,43],
full adherence to the guidelines is rarely achieved, however even partial compliance
improves the quality of research.” A TRIPOD guidelines checklist that describes the
critical aspects of our work has been provided in the supplementary materials (Table S8).
Our study has several limitations inherent to radiomic studies. The observed batch
effects of radiomic features related to oncologic centers (possibly due to use of different
CT machines or their settings) may be, for research purposes, solved by batch effect
removal tools developed for other high-throughput studies [
34,44]. However, such
procedure complicates the translation of results and has not been extensively validates in
terms of preserving data integrity. Furthermore, our data set has a relatively small sample
size and the developed models require further validation before they can be applied in
the clinical setting. Although the validation groups were sufficiently numbered to detect
statistically significant differences exceeding 13% of accuracy it would mandate a larger
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
11 of 18
Figure 5. Comparison of quality measures between external NTCP models (cool colors, 5 bars from the left) and our top
model selections (warm colors, 3 bars from the right), validation data.
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
12 of 18
Figure 6. Transformed (normalized and scaled) values of features retained in radiomic models. A: variant Ia, B: variant: Ib,
C: variant II.
study to confirm true non-interiority or equivalence of the radiomic and NTCP models,
but owing to the presented results planning such an endeavor is possible.
5. Conclusions
Radiomic models reliant on CT scans showed a similar or better predictive potential
for RIHT in OPC patients that the best currently used clinical and NTCP models with the
additional benefit of being independent of treatment planning and readily deployable
across different imaging data.
Supplementary Materials: The following are available online at https://www.mdpi.com/article/
10.3390/1010000/s1, Figure S1: Noramalization and scaling o radiomic features, Figure S2: Batch
effect correction, Figure S3: Distribution of radiomic features included in models, Table S1: Raw
patients’ data, Table S2: Raw values of radiomic features, Table S3: Parameters of analysed models’
architectures, Table S4: Stability of radiomic features, Table S5: Univariate analysis and filtration
of radiomic features, Table S6: List of radiomic features selected after univariate analysis, Table S7:
Quality metrics for all analysed models, Table S8: Tripod checklist for our study.
Author Contributions: Conceptualization, Zuzanna Nowicka, Wojciech Fendler and Bartlomiej
Tomasik; Data curation, Urszula Smyczynska, Szymon Grabia, Zuzanna Nowicka, Anna Papis-
Ubych, Robert Bibik, Tomasz Latusek, Tomasz Rutkowski, Jacek Fijuth and Bartlomiej Tomasik;
Formal analysis, Urszula Smyczynska, Szymon Grabia and Wojciech Fendler; Funding acquisition,
Zuzanna Nowicka, Wojciech Fendler and Bartlomiej Tomasik; Investigation, Urszula Smyczynska,
Szymon Grabia, Zuzanna Nowicka, Anna Papis-Ubych, Robert Bibik, Tomasz Latusek, Tomasz
Rutkowski, Jacek Fijuth and Bartlomiej Tomasik; Methodology, Urszula Smyczynska, Szymon
Grabia, Zuzanna Nowicka and Bartlomiej Tomasik; Project administration, Wojciech Fendler
and Bartlomiej Tomasik; Resources, Anna Papis-Ubych, Robert Bibik, Tomasz Latusek, Tomasz
Rutkowski, Jacek Fijuth and Bartlomiej Tomasik; Software, Urszula Smyczynska and Szymon
Grabia; Supervision, Wojciech Fendler; Validation, Urszula Smyczynska, Szymon Grabia and
Zuzanna Nowicka; Visualization, Urszula Smyczynska and Szymon Grabia; Writing – original
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
13 of 18
draft, Urszula Smyczynska, Szymon Grabia, Zuzanna Nowicka, Wojciech Fendler and Bartlomiej
Tomasik; Writing – review & editing, Urszula Smyczynska, Szymon Grabia, Zuzanna Nowicka,
Anna Papis-Ubych, Robert Bibik, Tomasz Latusek, Tomasz Rutkowski, Jacek Fijuth, Wojciech
Fendler and Bartlomiej Tomasik.
Funding: This research was funded by the FIRST TEAM project financed from the Smart Growth
Operational Program and coordinated by the Foundation for Polish Science, by the PRELUDIUM
project financed by the National Science Center (NCN) (2016/21/N/NZ5/01938) granted to BT,
by the Medical University of Lodz grant number 564/1-000-00/564-20-025 granted to ZN.
Institutional Review Board Statement: The study was conducted according to the guidelines of
the Declaration of Helsinki, and approved by the Bioethics Committee of the Medical University
of Lodz (KE/7/10, RNN/65/18).
Informed Consent Statement:
Informed consent was obtained from all subjects involved in the
study.
Data Availability Statement: Raw, anonymized clinical data and values of calculated radiomic
features were included in supplementary material.
Acknowledgments: Bartłomiej Tomasik gratefully acknowledges the financial support provided
by the Foundation for Polish Science and by the Polish National Agency for Academic Exchange
(the Walczak Programme).
Conflicts of Interest: The authors declare no conflict of interest.
Abbreviations
The following abbreviations are used in this manuscript:
AUC area under curve
CT computed tomography
FDR alse discovery rate
GLCM gray level cooccurrence matrix
GLDM gray level dependence matrix
GLRLM gray level run length matrix
GLSZM gray level size zone matrix
GPC Gaussian process classifier
HNG head and neck cancer
ICC inter-class correlation coefficient
IMRT intensity-modulated radiation therapy
MLP multilayer perceptron
NGTDM neighborhood gray tone difference matrix
NTCP normal tissue complication probability
OAR organ at risk
OPC oropharyngeal cancer
PACS picture archiving and communication system
ROI region of interest
RT radiation therapy
RIHT radiation-induced hypothyroidism
Appendix A. List of calculated radiomic features
Shape features
• elongation
• flatness
• least axis length
• major axis length
• maximum 2D diameter column
• maximum 2D diameter row
• maximum 2D diameter slice
• maximum 3D diameter
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
14 of 18
• mesh volume
• minor axis length
• sphericity
• surface area
• surface volume ratio
• voxel volume
First order features
• 10. percentile
• 90. percentile
• energy
• entropy
• interquartile range
• kurtosis
• maximum
• mean absolute deviation
• mean
• median
• minimum
• range
• robust mean absolute deviation
• root mean squared
• skewness
• total energy
• uniformity
• variance
Gray level cooccurrence matrix-based (GLCM) features
• autocorrelation
• cluster prominence
• cluster shade
• cluster tendency
• contrast
• correlation
• difference average
• difference entropy
• difference variance
• inverse difference (ID), homogeneity 1
• inverse difference moment (IDM), homogeneity 2
• inverse difference moment normalized (IDMN)
• inverse difference normalized (IDN)
• informational measure of correlation 1 (IMC1)
• informational measure of correlation 2 (IMC2)
• inverse variance
• joint average
• joint energy
• joint entropy
• maximal correlation coefficient (MCC)
• maximum probability
• sum average
• sum entropy
• sum squares
Gray level dependence matrix-based (GLDM) features
• dependence entropy
• dependence non uniformity
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
15 of 18
• dependence non uniformity normalized
• dependence variance
• gray level non uniformity
• gray level variance
• high gray level emphasis
• large dependence emphasis
• large dependence high gray level emphasis
• large dependence low gray level emphasis
• low gray level emphasis
• small dependence emphasis
• small dependence high gray level emphasis
• small dependence low gray level emphasis
Gray level run length matrix-based (GLRLM) features
• gray level non uniformity
• gray level non uniformity normalized
• gray level variance
• high gray level run emphasis
• long run emphasis
• long run high gray level emphasis
• long run low gray level emphasis
• low gray level run emphasis
• run entropy
• run length non uniformity
• run length non uniformity normalized
• run percentage
• run variance
• short run emphasis
• short run high gray level emphasis
• short run low gray level emphasis
Gray level size zone matrix-based (GLSZM) features
• gray level non uniformity
• gray level non uniformity normalized
• gray level variance
• high gray level zone emphasis
• large area emphasis
• large area high gray level emphasis
• large area low gray level emphasis
• low gray level zone emphasis
• size zone non uniformity
• size zone non uniformity normalized
• small area emphasis
• small area high gray level emphasis
• small area low gray level emphasis
• zone entropy
• zone percentage
• zone variance
Neighborhood gray tone difference matrix-based (NGTDM) features
• busyness
• coarseness
• complexity
• contrast
• strength
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
16 of 18
References
1. Brodin, N.P .; Kabarriti, R.; Garg, M.K.; Guha, C.; Tome, W.A. Systematic Review of Normal Tissue Complication Models Relevant
to Standard Fractionation Radiation Therapy of the Head and Neck Region Published After the QUANTEC Reports. International
Journal of Radiation Oncology Biology Physics 2018, 100, 391–407. doi:10.1016/j.ijrobp.2017.09.041.
2. Vigário, P .; Teixeira, P .; Reuters, V .; Almeida, C.; Maia, M.; Silva, M.; Vaisman, M. Perceived health status of women with overt
and subclinical hypothyroidism. Medical principles and practice 2009, 18, 317–322. doi:10.1159/000215731.
3. Thvilum, M.; Brandt, F.; Almind, D.; Christensen, K.; Hegedüs, L.; Brix, T.H. Excess mortality in patients diagnosed with
hypothyroidism: a nationwide cohort study of singletons and twins. The Journal of clinical endocrinology and metabolism
2013,
98, 1069–1075. doi:10.1210/JC.2012-3375.
4. Hassan, A.; Altamirano-Ufion, A.; Zulfiqar, B.; Boddu, P . Sub-Clinical Hypothyroidism and Its Association With Increased
Cardiovascular Mortality: Call for Action. Cardiology Research 2017, 8, 31–35. doi:10.14740/CR524W.
5. Rønjom, M.F.; Brink, C.; Bentzen, S.M.; Hegedüs, L.; Overgaard, J.; Johansen, J. Hypothyroidism after primary radiotherapy
for head and neck squamous cell carcinoma: normal tissue complication probability modeling with latent time correction.
Hypothyroidism after primary radiotherapy for head and neck squamous cell carcinoma: normal tissue complication probability modeling with
latent time correction 2013, 109, 317–322. doi:10.1016/J.RADONC.2013.06.029.
6. Kamal, M.; Peeler, C.R.; Yepes, P .; Mohamed, A.S.; Blanchard, P .; Frank, S.; Chen, L.; Jethanandani, A.; Kuruvilla, R.; Greiner, B.;
Harp, J.; Granberry, R.; Mehta, V .; Rock, C.; Hutcheson, K.; Cardenas, C.; Gunn, G.B.; Fuller, C.; Mirkovic, D. Radiation-Induced
Hypothyroidism After Radical Intensity Modulated Radiation Therapy for Oropharyngeal Carcinoma. Advances in Radiation
Oncology 2020, 5, 111–119. doi:10.1016/j.adro.2019.08.006.
7. Nowicka, Z.; Tomasik, B.; Papis-Ubych, A.; Bibik, R.; Graczyk, Ł.; Latusek, T.; Rutkowski, T.; Wyka, K.; Fijuth, J.; Schoenfeld,
J.D.; Chałubi ´ nska-Fendler, J.; Fendler, W. Radiation-induced hypothyroidism in patients with oropharyngeal cancer treated
with imrt: Independent and external validation of five normal tissue complication probability models. Cancers 2020, 12, 1–14.
doi:10.3390/cancers12092716.
8. Rønjom, M.F.; Brink, C.; Bentzen, S.M.; Hegedüs, L.; Overgaard, J.; Petersen, J.B.; Primdahl, H.; Johansen, J. External validation of
a normal tissue complication probability model for radiation-induced hypothyroidism in an independent cohort. Acta Oncologica
2015, 54, 1301–1309. doi:10.3109/0284186X.2015.1064160.
9. Boomsma, M.J.; Bijl, H.P .; Christianen, M.E.; Beetz, I.; Chouvalova, O.; Steenbakkers, R.J.; Van Der Laan, B.F.; Wolffenbuttel, B.H.;
Oosting, S.F.; Schilstra, C.; Langendijk, J.A. A prospective cohort study on radiation-induced hypothyroidism: Development of
an NTCP model. International Journal of Radiation Oncology Biology Physics 2012, 84, e351–e356. doi:10.1016/j.ijrobp.2012.05.020.
10.
Lambin, P .; Rios-Velazquez, E.; Leijenaar, R.; Carvalho, S.; Van Stiphout, R.G.; Granton, P .; Zegers, C.M.; Gillies, R.; Boellard, R.;
Dekker, A.; Aerts, H.J. Radiomics: Extracting more information from medical images using advanced feature analysis. European
Journal of Cancer 2012, 48, 441–446. doi:10.1016/j.ejca.2011.11.036.
11. Zwanenburg, A.; Vallières, M.; Abdalah, M.A.; Aerts, H.J.W.L.; Andrearczyk, V .; Apte, A.; Ashrafinia, S.; Bakas, S.; Beukinga,
R.J.; Boellaard, R.; Bogowicz, M.; Boldrini, L.; Buvat, I.; Cook, G.J.R.; Davatzikos, C.; Depeursinge, A.; Desseroit, M.C.; Dinapoli,
N.; Dinh, C.V .; Echegaray, S.; El Naqa, I.; Fedorov, A.Y.; Gatta, R.; Gillies, R.J.; Goh, V .; Götz, M.; Guckenberger, M.; Ha, S.M.;
Hatt, M.; Isensee, F.; Lambin, P .; Leger, S.; Leijenaar, R.T.; Lenkowicz, J.; Lippert, F.; Losnegård, A.; Maier-Hein, K.H.; Morin, O.;
Müller, H.; Napel, S.; Nioche, C.; Orlhac, F.; Pati, S.; Pfaehler, E.A.; Rahmim, A.; Rao, A.U.; Scherer, J.; Siddique, M.M.; Sijtsema,
N.M.; Socarras Fernandez, J.; Spezi, E.; Steenbakkers, R.J.; Tanadini-Lang, S.; Thorwarth, D.; Troost, E.G.; Upadhaya, T.; Valentini,
V .; van Dijk, L.V .; van Griethuysen, J.; van Velden, F.H.; Whybra, P .; Richter, C.; Löck, S. The Image Biomarker Standardization
Initiative: Standardized Quantitative Radiomics for High-Throughput Image-based Phenotyping. Radiology 2020, p. 191145.
doi:10.1148/radiol.2020191145.
12. Aerts, H.J.; Velazquez, E.R.; Leijenaar, R.T.; Parmar, C.; Grossmann, P .; Carvalho, S.; Bussink, J.; Monshouwer, R.; Haibe-Kains,
B.; Rietveld, D.; Hoebers, F.; Rietbergen, M.M.; Leemans, C.R.; Dekker, A.; Quackenbush, J.; Gillies, R.J.; Lambin, P . Decoding
tumour phenotype by noninvasive imaging using a quantitative radiomics approach. Nature Communications 2014, 5, 4006.
doi:10.1038/ncomms5006.
13. Leijenaar, R.T.; Carvalho, S.; Hoebers, F.J.; Aerts, H.J.; Van Elmpt, W.J.; Huang, S.H.; Chan, B.; Waldron, J.N.; Osullivan, B.;
Lambin, P . External validation of a prognostic CT-based radiomic signature in oropharyngeal squamous cell carcinoma.Acta
Oncologica 2015, 54, 1423–1429. doi:10.3109/0284186X.2015.1061214.
14. Nardone, V .; Tini, P .; Pastina, P .; Botta, C.; Reginelli, A.; Carbone, S.F.; Giannicola, R.; Calabrese, G.; Tebala, C.; Guida, C.; Giudice,
A.; Barbieri, V .; Tassone, P .; Tagliaferri, P .; Cappabianca, S.; Capasso, R.; Luce, A.; Caraglia, M.; Mazzei, M.A.; Pirtoli, L.; Correale,
P . Radiomics predicts survival of patients with advanced non-small cell lung cancer undergoing PD-1 blockade using Nivolumab.
Oncology Letters 2020, 19, 1559–1566. doi:10.3892/ol.2019.11220.
15. Vallières, M.; Kay-Rivest, E.; Perrin, L.J.; Liem, X.; Furstoss, C.; Aerts, H.J.; Khaouam, N.; Nguyen-Tan, P .F.; Wang, C.S.; Sultanem,
K.; Seuntjens, J.; El Naqa, I. Radiomics strategies for risk assessment of tumour failure in head-and-neck cancer. Scientific Reports
2017, 7, 1–14, [1703.08516]. doi:10.1038/s41598-017-10371-5.
16. Grossmann, P .; Stringfield, O.; El-Hachem, N.; Bui, M.M.; Rios Velazquez, E.; Parmar, C.; Leijenaar, R.T.; Haibe-Kains, B.;
Lambin, P .; Gillies, R.J.; Aerts, H.J. Defining the biological basis of radiomic phenotypes in lung cancer. eLife
2017, 6.
doi:10.7554/eLife.23421.
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
17 of 18
17. Leijenaar, R.T.; Bogowicz, M.; Jochems, A.; Hoebers, F.J.; Wesseling, F.W.; Huang, S.H.; Chan, B.; Waldron, J.N.; O’Sullivan,
B.; Rietveld, D.; Leemans, C.R.; Brakenhoff, R.H.; Riesterer, O.; Tanadini-Lang, S.; Guckenberger, M.; Ikenberg, K.; Lambin, P .
Development and validation of a radiomic signature to predict HPV (p16) status from standard CT imaging: a multicenter study.
The British Journal of Radiology 2018, 91, 2017049811075.
18. Cong, M.; Feng, H.; Ren, J.L.; Xu, Q.; Cong, L.; Hou, Z.; yuan Wang, Y.; Shi, G. Development of a predictive radiomics
model for lymph node metastases in pre-surgical CT-based stage IA non-small cell lung cancer. Lung Cancer 2020, 139, 73–79.
doi:10.1016/j.lungcan.2019.11.003.
19. Kwan, J.Y.Y.; Su, J.; Huang, S.H.; Ghoraie, L.S.; Xu, W.; Chan, B.; Yip, K.W.; Giuliani, M.; Bayley, A.; Kim, J.; Hope, A.J.; Ringash,
J.; Cho, J.; McNiven, A.; Hansen, A.; Goldstein, D.; de Almeida, J.R.; Aerts, H.J.; Waldron, J.N.; Haibe-Kains, B.; O’Sullivan,
B.; Bratman, S.V .; Liu, F.F. Radiomic Biomarkers to Refine Risk Models for Distant Metastasis in HPV-related Oropharyngeal
Carcinoma. International Journal of Radiation Oncology Biology Physics 2018, 102, 1107–1116. doi:10.1016/j.ijrobp.2018.01.057.
20. Sun, R.; Limkin, E.J.; Vakalopoulou, M.; Dercle, L.; Champiat, S.; Han, S.R.; Verlingue, L.; Brandao, D.; Lancia, A.; Ammari, S.;
Hollebecque, A.; Scoazec, J.Y.; Marabelle, A.; Massard, C.; Soria, J.C.; Robert, C.; Paragios, N.; Deutsch, E.; Ferté, C. A radiomics
approach to assess tumour-infiltrating CD8 cells and response to anti-PD-1 or anti-PD-L1 immunotherapy: an imaging biomarker,
retrospective multicohort study. The Lancet Oncology 2018, 19, 1180–1191. doi:10.1016/S1470-2045(18)30413-3.
21. Pérez-Morales, J.; Tunali, I.; Stringfield, O.; Eschrich, S.A.; Balagurunathan, Y.; Gillies, R.J.; Schabath, M.B. Peritumoral and
intratumoral radiomic features predict survival outcomes among patients diagnosed in lung cancer screening. Scientific Reports
2020, 10, 1–15. doi:10.1038/s41598-020-67378-8.
22. Vaidya, P .; Bera, K.; Gupta, A.; Wang, X.; Corredor, G.; Fu, P .; Beig, N.; Prasanna, P .; Patil, P .D.; Velu, P .D.; Rajiah, P .; Gilkeson, R.;
Feldman, M.D.; Choi, H.; Velcheti, V .; Madabhushi, A. CT derived radiomic score for predicting the added benefit of adjuvant
chemotherapy following surgery in stage I, II resectable non-small cell lung cancer: a retrospective multicohort study for outcome
prediction. The Lancet Digital Health 2020, 2, e116–e128. doi:10.1016/S2589-7500(20)30002-9.
23. Coroller, T.P .; Agrawal, V .; Huynh, E.; Narayan, V .; Lee, S.W.; Mak, R.H.; Aerts, H.J. Radiomic-Based Pathological Re-
sponse Prediction from Primary Tumors and Lymph Nodes in NSCLC. Journal of Thoracic Oncology
2017, 12, 467–476.
doi:10.1016/j.jtho.2016.11.2226.
24. Sha, X.; Gong, G.; Qiu, Q.; Duan, J.; Li, D.; Yin, Y. Discrimination of mediastinal metastatic lymph nodes in NSCLC based on
radiomic features in different phases of CT imaging. BMC Medical Imaging 2020, 20, 1–8. doi:10.1186/s12880-020-0416-3.
25. van Dijk, L.V .; Brouwer, C.L.; van der Schaaf, A.; Burgerhof, J.G.; Beukinga, R.J.; Langendijk, J.A.; Sijtsema, N.M.; Steenbakkers,
R.J. CT image biomarkers to improve patient-specific prediction of radiation-induced xerostomia and sticky saliva. Radiotherapy
and Oncology 2017, 122, 185–191. doi:10.1016/j.radonc.2016.07.007.
26. Gabry´ s, H.S.; Buettner, F.; Sterzing, F.; Hauswald, H.; Bangert, M. Design and Selection of Machine Learning Methods Using
Radiomics and Dosiomics for Normal Tissue Complication Probability Modeling of Xerostomia. Frontiers in Oncology 2018, 8, 35.
doi:10.3389/FONC.2018.00035.
27. Krafft, S.P .; Rao, A.; Stingo, F.; Briere, T.M.; Court, L.E.; Liao, Z.; Martel, M.K. The utility of quantitative CT radiomics features for
improved prediction of radiation pneumonitis. Medical Physics 2018, 45, 5317–5324. doi:10.1002/MP .13150.
28. Lucia, F.; Bourbonne, V .; Visvikis, D.; Miranda, O.; Gujral, D.M.; Gouders, D.; Dissaux, G.; Pradier, O.; Tixier, F.; Jaouen, V .; Bert, J.;
Hatt, M.; Schick, U. Radiomics Analysis of 3D Dose Distributions to Predict Toxicity of Radiotherapy for Cervical Cancer. Journal
of Personalized Medicine 2021, 11, 398. doi:10.3390/JPM11050398.
29. Rossi, L.; Bijman, R.; Schillemans, W.; Aluwini, S.; Cavedon, C.; Witte, M.; Incrocci, L.; Heijmen, B. Texture analysis of 3D
dose distributions for predictive modelling of toxicity rates in radiotherapy. Radiotherapy and Oncology
2018, 129, 548–553.
doi:10.1016/J.RADONC.2018.07.027.
30. Bourbonne, V .; Da-ano, R.; Jaouen, V .; Lucia, F.; Dissaux, G.; Bert, J.; Pradier, O.; Visvikis, D.; Hatt, M.; Schick, U. Radiomics
analysis of 3D dose distributions to predict toxicity of radiotherapy for lung cancer. Radiotherapy and Oncology 2021, 155, 144–150.
doi:10.1016/J.RADONC.2020.10.040.
31. Phil, T. Sikerdebaard/dcmrtstruct2nii: v1.0.19, 2020. doi:10.5281/ZENODO.4037865.
32.
Van Griethuysen, J.J.; Fedorov, A.; Parmar, C.; Hosny, A.; Aucoin, N.; Narayan, V .; Beets-Tan, R.G.; Fillion-Robin, J.C.; Pieper,
S.; Aerts, H.J. Computational radiomics system to decode the radiographic phenotype. Cancer Research 2017, 77, e104–e107.
doi:10.1158/0008-5472.CAN-17-0339.
33. Yeo, I.K.; Johnson, R. A new family of power transformations to improve normality or symmetry. Biometrika 2000, 87, 954–959.
doi:10.1093/biomet/87.4.954.
34. Johnson, W.E.; Li, C.; Rabinovic, A. Adjusting batch effects in microarray expression data using empirical Bayes methods.
Biostatistics 2007, 8, 118–127. doi:10.1093/biostatistics/kxj037.
35. Pedregosa, F.; Varoquaux, G.; Gramfort, A.; Michel, V .; Thirion, B.; Grisel, O.; Blondel, M.; Prettenhofer, P .; Weiss, R.; Dubourg, V .;
Vanderplas, J.; Passos, A.; Cournapeau, D.; Brucher, M.; Perrot, M.; Duchesnay, É. Scikit-learn: Machine Learning in Python.
Journal of Machine Learning Research 2011, 12, 2825–2830.
36. Raschka, S. MLxtend: Providing machine learning and data science utilities and extensions to Python’s scientific computing
stack. The Journal of Open Source Software 2018, 3. doi:10.21105/joss.00638.
. CC-BY-ND 4.0 International licenseIt is made available under a
perpetuity.
is the author/funder, who has granted medRxiv a license to display the preprint in(which was not certified by peer review)preprint
The copyright holder for thisthis version posted September 26, 2021. ; https://doi.org/10.1101/2021.09.23.21264007doi: medRxiv preprint
18 of 18
37. Bakhshandeh, M.; Hashemi, B.; Mahdavi, S.R.M.; Nikoofar, A.; Vasheghani, M.; Kazemnejad, A. Normal tissue complication
probability modeling of radiation-induced hypothyroidism after head-and-neck radiation therapy. International Journal of
Radiation Oncology Biology Physics 2013, 85, 514–521. doi:10.1016/j.ijrobp.2012.03.034.
38. Cella, L.; Liuzzi, R.; Conson, M.; D’Avino, V .; Salvatore, M.; Pacelli, R. Development of multivariate NTCP models for radiation-
induced hypothyroidism: a comparative analysis. Radiation Oncology 2012, 7, 224. doi:10.1186/1748-717X-7-224.
39. Vogelius, I.R.; Bentzen, S.M.; Maraldo, M.V .; Petersen, P .M.; Specht, L. Risk factors for radiation-induced hypothyroidism: A
literature-based meta-analysis. Cancer 2011, 117, 5250–5260. doi:10.1002/cncr.26186.
40. Lambin, P .; Leijenaar, R.T.H.; Deist, T.M.; Peerlings, J. Radiomics: the bridge between medical imaging and personalized medicine.
Nature Reviews Clinical Oncology 2017, 14, 749–762. doi:10.1038/nrclinonc.2017.141.
41. Zwanenburg, A.; Leger, S.; Agolli, L.; Pilz, K.; Troost, E.G.; Richter, C.; Löck, S. Assessing robustness of radiomic features by
image perturbation. Scientific Reports 2019, 9, 1–31, [1806.06719]. doi:10.1038/s41598-018-36938-4.
42. Sanduleanu, S.; Woodruff, H.C.; de Jong, E.E.; van Timmeren, J.E.; Jochems, A.; Dubois, L.; Lambin, P . Tracking tumor
biology with radiomics: A systematic review utilizing a radiomics quality score. Radiotherapy and Oncology 2018, 127, 349–360.
doi:10.1016/j.radonc.2018.03.033.
43. Park, J.E.; Kim, D.; Kim, H.S.; Park, S.Y.; Kim, J.Y.; Cho, S.J.; Shin, J.H.; Kim, J.H. Quality of science and reporting of radiomics in
oncologic studies: room for improvement according to radiomics quality score and TRIPOD statement. European Radiology 2020,
30, 523–536. doi:10.1007/s00330-019-06360-z.
44. Vuong, D.; Bogowicz, M.; Denzler, S.; Oliveira, C.; Foerster, R.; Amstutz, F.; Gabry´ s, H.S.; Unkelbach, J.; Hillinger, S.; Thierstein, S.;
Xyrafas, A.; Peters, S.; Pless, M.; Guckenberger, M.; Tanadini-Lang, S. Comparison of robust to standardized CT radiomics models
to predict overall survival for non-small cell lung cancer patients. Medical Physics 2020, p. mp.14224. doi:10.1002/mp.14224.