Microstructure and color stability of calcium silicate-based dental materials exposed to blood or platelet-rich fibrin
preprint
OA: closed
Abstract
Objectives: To investigate the effects of blood and platelet-rich fibrin (PRF) on the hydration, microstructure, and color stability of three hydraulic calcium silicate cements (HCSCs), OrthoMTA, RetroMTA, and TotalFill-BC-RRM. Materials: and methods The HCSCs were prepared and placed into polyethene molds and transferred to Eppendorf tubes containing PRF, blood, or PBS then incubated for 1 week or 1 month. The microstructure and hydration of the cements were studied by scanning electron microscopy (SEM), Energy-dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The chromatic alteration of materials was also measured using a spectrophotometer. The data for color stability were analyzed using 2-way analysis of variance. Results: There was no significant difference between the color stability of cements exposed to PBS ( p > 0.05). The chromatic alteration of cements exposed to blood was significantly greater than those exposed to PRF and PBS ( p < 0.001). In the presence of blood and PRF, the color change of OrthoMTA was significantly greater than that of RetroMTA and TotalFill (p 0.05). XRD analysis of all cements, revealed a calcium hydroxide peak after 1-week and 1-month exposure to the media; however, OrthoMTA and TotalFill exposed to blood and PRF for 1 month were associated with a reduction of the calcium hydroxide peak. SEM images revealed cements exposed to PBS had a different surface microstructure compared to those exposed to blood and PRF. Furthermore, the surface microstructure of HCSCs was influenced by the type of cement radiopacifier (bismuth oxide or zirconium oxide). EDS analysis of the elemental composition in all groups displayed peaks of Ca, O, C, Si, P and Al. Conclusions: Color stability, hydration behavior and microstructure of HCSCs were affected by exposure to PRF and blood and the type of cement radiopacifier. Clinical relevance As some important physicochemical properties of HCSCs could be influenced by the environmental conditions and the type of radiopacifier, alternatives to blood clot and HCSCs containing substitutes for bismuth oxide might be more suitable in RETs.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00