Automated Oxygen Delivery in Home Setting for Patients with COPD on Long-Term Oxygen Therapy – a randomized crossover feasibility trial | medRxiv /* */ /* */ <!-- <!-- /*! * yepnope1.5.4 * (c) WTFPL, GPLv2 */ (function(a,b,c){function d(a){return"[object Function]"==o.call(a)}function e(a){return"string"==typeof a}function f(){}function g(a){return!a||"loaded"==a||"complete"==a||"uninitialized"==a}function h(){var a=p.shift();q=1,a?a.t?m(function(){("c"==a.t?B.injectCss:B.injectJs)(a.s,0,a.a,a.x,a.e,1)},0):(a(),h()):q=0}function i(a,c,d,e,f,i,j){function k(b){if(!o&&g(l.readyState)&&(u.r=o=1,!q&&h(),l.onload=l.onreadystatechange=null,b)){"img"!=a&&m(function(){t.removeChild(l)},50);for(var d in y[c])y[c].hasOwnProperty(d)&&y[c][d].onload()}}var j=j||B.errorTimeout,l=b.createElement(a),o=0,r=0,u={t:d,s:c,e:f,a:i,x:j};1===y[c]&&(r=1,y[c]=[]),"object"==a?l.data=c:(l.src=c,l.type=a),l.width=l.height="0",l.onerror=l.onload=l.onreadystatechange=function(){k.call(this,r)},p.splice(e,0,u),"img"!=a&&(r||2===y[c]?(t.insertBefore(l,s?null:n),m(k,j)):y[c].push(l))}function j(a,b,c,d,f){return q=0,b=b||"j",e(a)?i("c"==b?v:u,a,b,this.i++,c,d,f):(p.splice(this.i++,0,a),1==p.length&&h()),this}function k(){var a=B;return a.loader={load:j,i:0},a}var l=b.documentElement,m=a.setTimeout,n=b.getElementsByTagName("script")[0],o={}.toString,p=[],q=0,r="MozAppearance"in l.style,s=r&&!!b.createRange().compareNode,t=s?l:n.parentNode,l=a.opera&&"[object Opera]"==o.call(a.opera),l=!!b.attachEvent&&!l,u=r?"object":l?"script":"img",v=l?"script":u,w=Array.isArray||function(a){return"[object Array]"==o.call(a)},x=[],y={},z={timeout:function(a,b){return b.length&&(a.timeout=b[0]),a}},A,B;B=function(a){function b(a){var a=a.split("!"),b=x.length,c=a.pop(),d=a.length,c={url:c,origUrl:c,prefixes:a},e,f,g;for(f=0;f<d;f++)g=a[f].split("="),(e=z[g.shift()])&&(c=e(c,g));for(f=0;f<b;f++)c=x[f](c);return c}function g(a,e,f,g,h){var i=b(a),j=i.autoCallback;i.url.split(".").pop().split("?").shift(),i.bypass||(e&&(e=d(e)?e:e[a]||e[g]||e[a.split("/").pop().split("?")[0]]),i.instead?i.instead(a,e,f,g,h):(y[i.url]?i.noexec=!0:y[i.url]=1,f.load(i.url,i.forceCSS||!i.forceJS&&"css"==i.url.split(".").pop().split("?").shift()?"c":c,i.noexec,i.attrs,i.timeout),(d(e)||d(j))&&f.load(function(){k(),e&&e(i.origUrl,h,g),j&&j(i.origUrl,h,g),y[i.url]=2})))}function h(a,b){function c(a,c){if(a){if(e(a))c||(j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}),g(a,j,b,0,h);else if(Object(a)===a)for(n in m=function(){var b=0,c;for(c in a)a.hasOwnProperty(c)&&b++;return b}(),a)a.hasOwnProperty(n)&&(!c&&!--m&&(d(j)?j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}:j[n]=function(a){return function(){var b=[].slice.call(arguments);a&&a.apply(this,b),l()}}(k[n])),g(a[n],j,b,n,h))}else!c&&l()}var h=!!a.test,i=a.load||a.both,j=a.callback||f,k=j,l=a.complete||f,m,n;c(h?a.yep:a.nope,!!i),i&&c(i)}var i,j,l=this.yepnope.loader;if(e(a))g(a,0,l,0);else if(w(a))for(i=0;i (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0];var j=d.createElement(s);var dl=l!='dataLayer'?'&l='+l:'';j.src='//www.googletagmanager.com/gtm.js?id='+i+dl;j.type='text/javascript';j.async=true;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-P4HH5NV'); Skip to main content Home About Submit ALERTS / RSS Search for this keyword Advanced Search Automated Oxygen Delivery in Home Setting for Patients with COPD on Long-Term Oxygen Therapy – a randomized crossover feasibility trial View ORCID Profile Linette Marie Kofod , View ORCID Profile Ejvind Frausing Hansen , View ORCID Profile Morten Tange Kristensen , View ORCID Profile Barbara Cristina Brocki , View ORCID Profile Elisabeth Westerdahl doi: https://doi.org/10.1101/2025.01.23.25320958 Linette Marie Kofod 1 PMR-C, Department of Physio- and Occupational Therapy, Copenhagen University Hospital , Hvidovre, Denmark 2 School of Medical Sciences, Faculty of Medicine and Health, Örebro University , Sweden Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Linette Marie Kofod For correspondence: linette.marie.kofod{at}regionh.dk Ejvind Frausing Hansen 3 Department of Pulmonology, Copenhagen University Hospital , Hvidovre, Denmark Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Ejvind Frausing Hansen Morten Tange Kristensen 4 Department of Physical and Occupational Therapy, Copenhagen University Hospital , Bispebjerg-Frederiksberg, Denmark 5 Department of Clinical Medicine, University of Copenhagen , Denmark Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Morten Tange Kristensen Barbara Cristina Brocki 6 Department of Physiotherapy and Occupational Therapy, Aalborg University Hospital , Denmark Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Barbara Cristina Brocki Elisabeth Westerdahl 7 University Health Care Research Center, Faculty of Medicine and Health, Örebro University , Sweden Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Elisabeth Westerdahl Abstract Full Text Info/History Metrics Data/Code Preview PDF Abstract Rationale Patients with COPD on long-term oxygen therapy (LTOT) have an unmet need for oxygen adjustments during sleep, rest, and activity, documented by continuous monitoring of oxygen saturation. While emerging technology enables automated adjustments, its feasibility in home settings remains uncertain. This randomized crossover trial evaluated the feasibility and preliminary effects of continuous automated oxygen titration in the homes of patients on LTOT. Methods The intervention involved four days of automated oxygen titration targeting a SpO₂ of 90-94% using a Bluetooth-connected electronic device and wrist pulse oximeter, forming a closed-loop system. Oxygen flow (0.9-6.8 L/min) was continuously adjusted based on SpO₂. During the control period, patients received their usual fixed dose oxygen. Feasibility was defined as successful automated titration time and time spent with normoxia. Changes in health status were measured using the Clinical COPD Questionnaire (CCQ). Results Twelve patients on LTOT (2.0±0.8 L/min) were included, with more than 217,000 paired SpO 2 and oxygen flow data points collected per patient. Oxygen flow was automatically adjusted for a median (IQR) of 77 (68.0–84.3) hours, covering 83% of the time. Time within target saturation increased significantly from 52% (42–63) to 86% (75–90) during intervention, with all patients utilizing the full available flow range. The CCQ score improved by 0.74±0.47 points, p <0.001. Conclusion Automated home oxygen titration is feasible, achieving more time with normoxia, but it required a wide flow range and continuous monitoring. The patients reported notable reductions in COPD symptoms. Introduction Oxygen is essential for human life. Regrettably, some patients with advanced COPD develop a reduced ability to deliver sufficient oxygen to the blood, resulting in chronic respiratory failure with the constant need of oxygen supplementation. In acute settings, oxygen treatment has become more restrictive, with increased focus on the dosage of oxygen for patients with acute hypoxemic respiratory failure, and it is recommended to maintain a target saturation with conservative oxygen doses, as it decreases mortality [ 1 – 3 ]. Several studies found that electronic, closed-loop devices, which automatically adjusts oxygen in response to the saturation, were more accurate in keeping the recommended saturation compared to manual adjustments [ 4 – 8 ]. In contrast, our understanding is limited when it comes to maintaining target saturation during daily living in the home setting. Fluctuating oxygen needs lead to episodes of desaturation and hypoxemia in patients with COPD [ 9 – 13 ]. Home oxygen is prescribed based on arterial blood gas analysis to achieve a PaO2 >8.0 kPa, corresponding to a peripheral oxygen saturation (SpO 2 ) of 90% at rest [ 14 , 15 ]. Although patients on long-term oxygen therapy (LTOT) use this prescribed fixed oxygen dose, continuous monitoring of oxygen saturation has revealed an unmet need for oxygen adjustments, depending on whether the patients are sleeping, sitting, or engaging in daily activities [ 11 , 16 ]. Clinical benefits of maintaining a target saturation are particular evident during walking tests, with increased walking capacity and alleviated dyspnea [ 17 – 19 ], but also when performing an activity of daily living (ADL) test [ 20 ]. Optimizing patients’ oxygen saturation through automated oxygen titration enhanced their ability to perform ADL and reduced their perceived breathlessness [ 20 ]. These results suggest that individually adjusted, automated oxygen flow may benefit patients in daily life by increasing time spent with normoxia. However, achieving this would require constant saturation monitoring around the clock and, consequently, continuous adjustments. Automated oxygen titration technology has advanced into the home setting, allowing closed-loop devices to be attached to the patients’ home concentrators. For oxygen flow to dynamically adjust in every situation, patients need to wear a pulse oximeter that communicates with the oxygen delivery system for most of the day. This represents a new approach, and it remains unclear how, or even if, such oxygen titration could be effectively managed. The aim of this randomized crossover study was to evaluate the feasibility of automated oxygen titration as response to the saturation during daily living for four days in the home of patients with COPD on LTOT. Feasibility was defined as successful time during which the patients were automatically titrated, patientś willingness toward the intervention, and clinically relevance. Methods Study design This randomized crossover feasibility trial was conducted in the homes of 12 patients with COPD on LTOT. The patients were recruited from two departments of pulmonology at Copenhagen University Hospital, Hvidovre and Copenhagen University Hospital, Bispebjerg-Frederiksberg, Denmark, from January to December 2023 in connection with a scheduled study visit [ 20 ]. The study was approved by The Committees on Health Research Ethics in the Capital Region of Denmark (H-22032988) and the Danish Data Protection Agency j.nr. P-2022-625. The study was registered at ClinicalTrials.gov ( NCT05556187 ), and the reporting followed the CONSORT statement for randomized pilot and feasibility trials. Participants ≤7.3 kPa), who were receiving LTOT according to the international criteria for home oxygen therapy [ 14 ], had the ability to walk independently (with or without a walking aid), and were cognitively able to participate. Exclusion criteria were an exacerbation in COPD treated with either antibiotics or prednisolone within the preceding three weeks or comorbidities known to impact physical functioning. Additionally, before randomization, each patient underwent two venous blood gas tests: the first with their usual oxygen dose and the second after 20 minutes of 8 L/min of oxygen. Venous blood gases (instead of arterial blood gases) were used to minimize discomfort to the patients [ 21 ]. The blood samples were analyzed for pH-value and PvCO 2 . The patients were excluded if they exhibited a drop in pH to 1 kPa compared to their usual fixed oxygen dose. Included patients provided written informed consent before participation. Intervention The automated oxygen period The intervention period consisted of four days with a continuous titration of the oxygen flow aiming at a target saturation between 90-94% using an electronic closed-loop device installed in the patientś homes. If SpO 2 dropped below 90% or exceeded 94% the oxygen flow was automatically adjusted according to the algorithm in the device. The fixed dose period For the control period, the patients received their usual fixed oxygen flow for four days, while monitoring and collecting data on SpO 2 and heart rate. The two periods were scheduled on comparable days to minimize significant variations in social or physical activities; however, no specific washout time was planned. In both periods, daily 24-hour physical activity were monitored with a body-worn device, and the patients used their usual portable oxygen concentrator when being outdoors. Study technology and data capture The automated oxygen period A closed-loop device O2matic Home Oxygen Treatment (HOT) (O2matic Ltd., Herlev, Denmark) was used for automated oxygen titration. The 9 L/min Invacare Platinum 9 concentrator (Invacare Ltd. Brøndby, Denmark) or the 10 L/min Caire NewLife Intensity concentrator (Medical Danmark Ltd., Ejby, Denmark) were used to produce oxygen and attached to the HOT device using a tube. The patients wore the Nonin Wrist Pulse Oximeter (Nonin Medical, Inc., USA) with the sensor well-attached to a finger using a sensor tape, Figure 1 . The pulse oximeter transmitted data on SpO 2 and heart rate to the HOT device. The adjustments on oxygen were done every second based on average SpO 2 for the last 15 seconds. All parameters regarding the individual patient settings could only be changed in the Installer tablet handled by the investigator. The SpO 2 target interval and a flow range was set at the beginning of the intervention. A previous study identified an mean oxygen demand of 8 L/min during a walking test [ 19 ]. Download figure Open in new tab Figure 1 Artistic presentation of the automated oxygen delivery setup. A) Pulse oximeter, which transmits oxygen saturation data via Bluetooth to the closed-loop devise, B) Closed-loop device, that titrates oxygen via the high-flow nasal cannula to the patient, C) Oxygen concentrator, D) Patient tablet, displaying the current saturation, oxygen flow and heart rate. The patient tablet also transmits information via Wi-fi to the online platform. Therefore, the aim was an oxygen flow from 0.5 to 8.0 L/min. However, the concentrators were only able to deliver a stable flow between 0.8 and 6.8 L/min. In case the patients removed the pulse oximeter (or experienced a general loss of signal) for more than two minutes the flow would return to usual flow ±1 L/min and stay there until the signal was restored. Data collection The close-loop device transmitted data to an app on the patient-tablet. The data were then relayed via Wi-Fi to a secure web platform based on Microsoft Azure cloud services, where it could be accessed by the principal investigator as needed. The patients could also observe live data on the tablet if they wished. In case of a disconnection to the patient-tablet, data were stored locally on the closed-loop device and transmitted once the connection was restored. During such interruptions, the oxygen flow to the patient remained automated titrated, and the stored data could later be accessed on the online platform as summarized, non-live data files. Live data refers to every-second-real-time measurements of heart rate, SpO 2 , and oxygen flow, which could be extracted from CSV files. The fixed dose period During the fixed dose period, the patients wore the same wrist pulse oximeter as during the intervention. Since automated oxygen titration could only be administered in the patient’s home, we instructed the patients to remove the pulse oximeters when leaving the house during the control period, so that data was only collected when being indoors. Data collection The data on SpO 2 and heart rate were stored locally in the wrist oximeter. CSV files, used for analysis, was generated using Nonin’s nVISION Data Management Software. The batteries in the pulse oximeter needed to be changed every second day, and when removed, it resulted in a reset of date and time in the system. As a result, the collected data during the fixed dose period was untransparent, regarding the exact date and time. Step counts The physical activity was monitored equally in both study periods using the SENS motion accelerometer (SENS innovation ApS, Denmark). The miniature, waterproof accelerometer was placed with a patch above the patientś knee. It continuously recorded the movements, and synchronized with an app that uploaded the recorded data to a web server [ 22 ]. Summary files containing information on steps were accessed from SENS online platform and used for analysis. Outcome Feasibility The goal of this study was for patients to wear the pulse oximeter continuously during the daytime while having their oxygen adjusted automatically. We defined three key areas that needed to be fulfilled for it to be considered feasible: time when the patients were automatically titrated, patientś willingness toward the intervention and clinically relevance. Prior to the study, we established the following criteria: Data were successfully transmitted from the wrist pulse oximeter to the closed-loop device and further to the cloud solution (<10 % data loss), The patients wore the wrist pulse oximeter for more than 50% of the daytime (08:00-20:00), The time spent within target saturation was statistically different between arms and in favour of automated oxygen titration with a difference of at least 10%, The patients were at least as active with automated oxygen titration as with conventional fixed oxygen therapy, measured by the activity sensor, The patients were safe with no serious adverse events, leading to unscheduled healthcare contacts. Rationale for criteria 1, Titration time : Both live data and session summaries received on the platform were proof of “the time when the patients were automatically titrated”. The 10% threshold was based on experiences from three earlier studies on automated oxygen delivery [ 7 , 19 , 20 ]. Rationale for criteria 2, Patient willingness : We considered patients’ willingness to wear the wrist pulse oximeter in the day time from 8 a.m. to 8 p.m. as essential for continuous oxygen titration. Rationale for criteria 3 and 4, Clinical relevance : If automated oxygen titration did not improve oxygen saturation, it was deemed irrelevant. Therefore, we evaluated: differences in time spent with normoxia (SpO 2 90–94%), moderate hypoxemia (SpO 2 85-89%), severe hypoxemia (SpO 2 94%). Furthermore, we evaluated the patients’ physical activity level. Rationale for criteria 5, Patient safety: The setup was considered non-feasible if it posed notable risks to the patient, such as unscheduled contacts to the hospital due to acute-on-chronic respiratory failure. Secondary outcome At study start, after four days intervention, and after four days of usual care, the patients were assessed using the health status Clinical COPD Questionnaire (CCQ), 24 hour version [ 23 ]. The CCQ is validated in Danish, consists of ten questions across three domains: symptoms, mental state, and functional state. Each question is scored from 0 to 6, with a higher score indicating a lower health status. A Minimal Important Difference (MID) of 0.4 is considered clinically relevant [ 24 ]. The patients’ oxygen flow was compared between both study periods. Variables We included the following variables to describe the characteristics and clinical profile of the patients: age, gender, body mass index (BMI), pulmonary function and duration of LTOT, all of which were extracted from the patients’ medical records. Additionally, the patients were asked about their perceived dyspnea at rest, measured using the Borg CR10 dyspnea scale, their marital status, need for a walking aid, and frequency of engaging in activities outside their home. The patients also completed the modified Medical Research Council Dyspnea Scale (mMRC) and the COPD Assessment Test (CAT). Randomization and blinding The patients were randomized after inclusion to either the automated oxygen period followed by the fixed dose period, or vice versa. The randomization list was computer-generated compiled for each patient in REDCap electronic data capture tools (REDCap Consortium, Nashville, US) hosted at Capital Region of Denmark. Neither the patients nor the investigator were blinded. Statistical considerations Due to the feasibility design of the present study, a formal sample size calculation was not performed. In a non-feasibility design CCQ could be a primary outcome, which would require 42 patients to detect a MID of 0.4 with a standard deviation of 0.9. For the purpose of this feasibility study, we selected a sample of 12 patients, as we considered this number sufficient to assess feasibility. Furthermore, this sample size provided an adequate basis for evaluating variations in SpO 2 intervals and generating preliminary insights into the CCQ outcome. For the time-spent-within-target-analysis in this study, only live data extracted from CSV files were used. In Criteria 1, however, live data were supplemented with the duration of the non-live data to provide a complete picture of the ‘titration tim’. Continuous variables were examined for normality. Those meeting normality assumptions were analyzed with a paired t-test and presented as mean (standard deviation (SD)). For not normally distributed variables, the Wilcoxon signed-rank test was used, with data presented as median with interquartile range (IQR). CCQ was tested in a two-way ANOVA with treatment, period and an interaction term between treatment and period as explanatory variables to account for carryover effect bias. IBM SPSS Statistics for Windows, ver. 29.01 was used for all statistical analyses. GraphPad Prism version 10.1.2 for Windows was used for figure 3 and 4. Results Thirty-two patients were screened for eligibility, of whom 13 met the inclusion criteria and consented to participate, Figure 2 . One patient was subsequently excluded after venous blood gas analysis revealed a PCO₂ of 11.3 kPa and a pH decrease from 7.30 to 7.28 following 20 minutes with 8 L/min oxygen. Accordingly, 12 patients (four women and eight men) with a mean (SD) home oxygen dose of 2.0 (0.7) L/min were randomized, Table 1 . All patients completed the study. Download figure Open in new tab Figure 2 Flow diagram of inclusion of patients. View this table: View inline View popup Table 1 Characteristics and clinical profile of the study patients with COPD on long-term oxygen therapy, n=12 Feasibility During the four days of automated oxygen intervention, the patients had the equipment installed for median (IQR) 96 (94.7-96.0) hours. Detailed live data were received for each patient for 69.5 (53.3-82.8) hours, providing more than 217,000 paired data points on SpO 2 and oxygen flow per patient during the automated oxygen period, Table 2 . View this table: View inline View popup Download powerpoint Table 2 Patient reported outcome and physiological parameters, n=12 Criteria 1, Titration time : Data were received on the online platform for 77 (68.0–84.3) hours, meaning that patients’ oxygen flow was automatically titrated for 83% (74-88) of the possible time. Criteria 2, Patient willingness : Live data were received for 35.5 (26.3-42.5) hours for each patient, constituting 75% (64-88) of the daytime period. Of 12 patients, 11 patients wore the pulse oximeter for at least 50% of the time in the automated oxygen period. Criteria 3, Clinical relevance : Time spent with SpO₂ of 90–94% differed significantly between periods: 52% (42–63) with fixed oxygen flow versus 86% (75–90) with automated titration (p=0.002). Correspondingly, significant differences in favor of the automated oxygen intervention were also observed in time spent with moderate hypoxemia (p=0.003), severe hypoxemia (p=0.004), and hyperoxemia (p=0.01), as illustrated in Figure 3 . Download figure Open in new tab Figure 3 Percentage of time spent within oxygen saturation (SpO 2 ) intervals. Boxplot illustrating median, interquartile range, minimum and maximum time spent in the various intervals. X-axis: Four predefined oxygen saturations intervals. Y-axis: Percentage of time over a total period of four full days. *p ≤0.01. Criteria 4, Clinical relevance : The patients took 2297 (1519-3106) steps daily in the fixed dose period and 2366 (1236-3703) steps during the automated oxygen period, with no significant difference between periods (p=0.7). Criteria 5, Patient safety: Unintended events were observed during the intervention; none which required hospitalization or unscheduled healthcare visits. Some events triggered system alarms, primarily due to insufficient oxygen supply, see Table 3 . The patients expressed annoyance with the noise from the concentrator, the bulkiness of the pulse oximeter, and the frequent use of batteries. View this table: View inline View popup Table 3 Outlining of incidents during the automated oxygen period Secondary outcome The total score in the CCQ improved significantly by a mean of 0.74 (0.47) points favoring the automated oxygen intervention (p0.3), Table 2 . However, all 12 patients used the full range of possible oxygen flow during the automated oxygen period. During 34% (18) of the measured time, the patients’ oxygen flow was titrated up compared to their usual fixed oxygen dose, and in 38% (27) of the time it was decreased, Figure 4 . Download figure Open in new tab Figure 4 Various oxygen flow used during the automated oxygen period. The percentage of the time the patients spent using various oxygen flows during automated titration, expressed as changes in 1 L/min intervals from their usual fixed flow ±0.5 L/min. The striped bar represents the 29% (20) of the time, that the patients received their usual oxygen flow. The light purple bars indicate the percentage of time patients experienced decreased oxygen flow compared to their usual flow, while the dark purple bars represent the time in which the oxygen flow was increased. The test for carryover-effect showed neither significant difference in CCQ total score between the two periods nor significance of an interaction term between treatment and the period. Discussion We found that continuous automated oxygen titration in the homes of patients with COPD on LTOT was both feasible and well-tolerated, with high patient compliance. For more than 80% of the day, the patients’ oxygen flow was titrated based on their saturation, resulting in a significant improvement in oxygenation at home compared to when using their fixed dose. Furthermore, the patients reported a lower symptom burden, as measured by the CCQ, indicating a more positive perception of health status when oxygen saturation was improved. Target saturation and oxygen flow Interestingly, the mean oxygen flow and mean saturation levels were nearly identical across both study periods, which could suggest that automated oxygen titration offers limited added value. However, in 71% of the time that patients used automated oxygen delivery, their oxygen flow was automatically adjusted to a different rate than their usual fixed dose. Not only did the oxygen flow increase with up to additional 5 L/min, but in more than 33% of the time, the patientś oxygen flow was decreased compared to their usual fixed dose. This highlights the fluctuating oxygen needs at an individual level for each patient. This variability in oxygen flow corresponded to the significant improvements in the time spent within the target saturation. In line with these findings, fluctuating oxygen needs have been observed during walking [ 17 – 19 ], as well as in more home-related settings, such as during an ADL test. In this context, the mean oxygen flow increased from 1.6 to 5.2 L/min, while the time spent with severe hypoxemia (SpO2 <85%) decreased by 30% to 17% [ 20 ]. These improvements in oxygen saturation led to enhanced performance and reduced experiences of dyspnea. We found that the patients spent approximately 22% of the day with SpO₂ below 90% while using their usual fixed oxygen flow. This is slightly different from a study by Sliwinski et al., in which patients spent 30% of the day with hypoxemia [ 11 ]. Patients are typically more active outdoors, thus probably also more frequently experiencing hypoxemia, and this could explain the differences in time spent with hypoxemia between the present study and Sliwinski’s, where patients also were monitored while outdoors. Sliwinski did not report how long patients maintained a saturation above 94%. However, Zhu et al. argued that oxygen flow rates should be reduced during rest, as patients’ oxygen saturation were often too high [ 15 ]. In present study, we were surprised to find that patients with usual oxygen dose spent 24% of their time with saturation above the target range while at home. This corresponds to six hours per day with hyperoxemia, during which the patients could use a lower oxygen flow or, depending on the degree of respiratory failure, take a break from the nasal cannula. In line with this, Ekström et al. recently found that patients could pause oxygen therapy for up to nine hours per day without any consequences on mortality or hospitalization [ 25 ]. However, they did not monitor for how long time the patients were well treated without hypoxemia [ 25 ]. The NOTT and MRC studies from the 1980s established that reducing hypoxemia at rest by increasing PaO 2 above 8 kPa reduces mortality [ 26 , 27 ]. Oxygen use for 24 hours was found to be more beneficial than 12 hours, and 15 hours was better than no oxygen at all. However, it remains unclear whether the critical factor is the overall duration of oxygen therapy, or the time spent with effective oxygen therapy (PaO₂ >8 kPa). While the effect on mortality is one consideration, it is well established that improved oxygenation supports patients’ physical functioning and helps reduce breathlessness in controlled test settings. Whether improved oxygenation could lead to similar benefits on mortality in the home environment remains to be investigated, but our results suggested an effect on the patientś perceived symptoms which could be important to their daily life. Health status and daily step counts Health status, evaluated using the CCQ, could potentially detect improvements in patients’ ability to move with less dyspnea and participate in more social activities. In our 12-patient feasibility study, the CCQ overall score significantly favored the automated oxygen period, with a striking difference of 0.74 point, which is almost the double of the 0.4 MID established for the CCQ in this population. Both the symptoms and mental state domains of the CCQ showed significant improvement, supporting the hypothesis that optimized oxygenation can alleviate dyspnea, as also observed during walking and in ADL. Limited evidence exists on home-based interventions for patients with COPD that effectively improve health-related quality of life, particularly for those with severe disease, who often experience profoundly diminished quality of life [ 28 , 29 ]. Consequently, any home-based oxygen intervention that meaningfully reduces patients’ symptom burden is highly relevant. In general, the patients in the present study were not very active with approximately 2,300 steps per day, and with no significant difference between the two groups. Still, this aligns with previously reported for this severely ill group, typically ranging between 2,400 and 3,800 steps per day [ 30 ]. Given the short intervention of four days and that the intervention was only indoor in the present study, our criteria for feasibility related to physical activity (no difference between groups) was met. The study was not powered to find any difference in step counts and considering how difficult it is to change habits we did not expect to find a difference between groups. An essential factor in evaluating feasibility before considering a larger trial or implementation is the patients’ attitude toward the intervention. This includes the perceived burden of the technology and how well it aligns with what patients find personally meaningful and effective. Patients’ experiences are reported in a separate paper, gathered through qualitative interviews with the involved patients in the present study [ 31 ]. Equipment challenges The proper solution for maintaining a target saturation only emerged with the introduction of automated closed-loop devices for home use. Effective automated oxygen administration, aligned with our study goal of continuous saturation monitoring during daytime followed by automatic oxygen adjustments, requires the optimization of all system components. This includes the closed-loop device, the pulse oximeter, and the oxygen concentrator. Additionally, a patient tablet, strong Wi-Fi and coordination between all mentioned system parts are essential. A well-designed nasal cannula capable of delivering flows above 5 L/min without causing discomfort to the patient is also preferable. Early in the study, it became apparent that the concentrators were unable to sustain an 8 L/min flow, leading us to lower the maximum flow for consistent performance. Furthermore, the standard concentrator, typically used for flow rates higher than 5 L/min, was notable noisy and the reason for the patientś primary complains. The pulse oximeter was by many found to be uncomfortable for constant wear and too demanding in battery use. Before starting the study, we decided that data loss was important to look at (criteria 1). However, it turned out to be impossible to distinguish between times when the oximeter was deliberately removed (e.g., for a shower or when leaving the home), and time when the Bluetooth connection was unintentionally lost or when equipment malfunctioned. Therefore, we chose to disregard the 10% threshold, as it proved to be an unsuitable target. Adding an electronic device to the patient’s oxygen therapy system increases the risk of unintended events and system alarms. Some of these alarms are appropriate as they alert to an undesirable situation, such as low oxygen flow. Acting on alarms under current conditions requires that the patients have both auditory and visual awareness, along with sufficient cognitive capacity to respond adequately to alarms or, at a minimum, switch to their standard treatment if needed. Strength and limitation A key strength of the present study is the home setting, where patients behaved as they typically would, without the need for round-the-clock support. They engaged in their usual daily activities and moved around with their normal level of physical activity. This provided valuable insight into how automated oxygen titration might function in real-world conditions and its potential impact on patients’ daily lives. We believe, the data we received were reflective of real-life scenarios. Another strength is the extensive amount of data collected for each patient. We collected data over two four-day periods, providing a detailed overview of time spent in different SpO₂ intervals with and without the automated oxygen delivery. The same wrist pulse oximeter ensured consistent saturation measurements during both periods. A limitation of our study was the non-blinded design, which might lead patients to overestimate the positive impact of more adequate oxygenation. Additionally, the possibility for patients to contact the principal investigator in case of problems might have provided a comforting effect, making patients feel safer and more relaxed, despite this option being available in both study arms. Furthermore, the sample size is small in this feasibility study design, which limits our ability to draw definitive conclusions about the potential effects of the automated oxygen intervention. Conclusion Conclusively, automated oxygen therapy in the patientś home was feasible and it significantly increased the time patients spend with normoxia. This improvement seemed to potentially lower symptom burden such as dyspnea in daily life. To ensure safety and for patients to respond adequately to alarms, the ideal patient must have cognitive awareness as well as adequate hearing and vision. Data Availability Public deposition of raw data points is not possible due to Denmarks national legislation (Data Protection Act section 10 and Data Disclosure Proclamation Act) which outline that we can only transfer pseudonymized data to the Journal after the Data Protection Authorities approval (Data Protection Act section 10, part 3, nr. 3.). Reviewers and others may obtain access to the data by request, and after the Danish Data Protection Agency has approved of the data transfer from the Capital Region. If others are to gain access to the pseudonymized data, they shall ensure that is an adequate legal basis to share the Capital Regions data and ensure that the data is only being processed for scientific research purposes. Funding The study was funded by Innovation Fund Denmark grant nr. 8056-00054B, Swedish Respiratory Society (SMLF) and The Association of Danish Physiotherapists Research Fund. Disclosure statement The principal investigator has no conflicts of interest. One of the investigators (Ejvind Frausing Hansen) is a co-inventor of the closed-loop device and holds shares in O2matic Ltd. Neither the company nor the funders had influence on the protocol, the data analysis, or the writing of the scientific paper. Apart from the above conflict of interest the remaining investigators have none. Declaration of generative AI and AI-assisted technologies in the writing process During the preparation of this work the first author, used ChatGPT in the writing process in order to improve the readability of the manuscript. After using this tool/service, the authors reviewed and edited the content as needed and take full responsibility for the content of the published article. Acknowledgement A special thank you to Ida Heefelt for her support and assistance with blood gases. Thanks to O2matic Ltd. for adjusting the equipment to align with our study requirements and for consistently incorporating feedback from both our study team and the patients. References 1. ↵ Austin MA , Wills KE , Blizzard L , et al. Effect of high flow oxygen on mortality in chronic obstructive pulmonary disease patients in prehospital setting: randomised controlled trial . BMJ . 2010 ; 341 : c5462 . 2. Chu DK , Kim LH , Young PJ , Zamiri N , Almenawer SA , Jaeschke R , Szczeklik W , Schünemann HJ , Neary JD , Alhazzani W , et al. Mortality and morbidity in acutely ill adults treated with liberal versus conservative oxygen therapy (IOTA): a systematic review and meta-analysis . 2018 ;. 3. ↵ O’Driscoll BR , Howard LS , Earis J , et al. BTS guideline for oxygen use in adults in healthcare and emergency settings . Thorax . 2017 ; 72 (suppl Suppl 1 ): ii1 – ii90 . OpenUrl FREE Full Text 4. ↵ L’Her E , Dias P , Gouillou M , et al. Automatic versus manual oxygen administration in the emergency department . 2017 ;. 5. Hansen EF , Hove JD , Bech CS , et al. Automated oxygen control with O2matic((R)) during admission with exacerbation of COPD . Int J Chron Obstruct Pulmon Dis . 2018 ; 13 : 3997 – 4003 . OpenUrl CrossRef PubMed 6. Lellouche F , Bouchard PA , Roberge M , et al. Automated oxygen titration and weaning with FreeO2 in patients with acute exacerbation of COPD: a pilot randomized trial . Int J Chron Obstruct Pulmon Dis . 2016 ; 11 : 1983 – 1990 . OpenUrl CrossRef PubMed 7. ↵ Sandau C , Hansen EF , Ringbæk TJ , Kallemose T , Bove DG , Poulsen I , Nørholm V , Pedersen L , Jensen JUS , Ulrik CS . Automated Oxygen Administration Alleviates Dyspnea in Patients Admitted with Acute Exacerbation of COPD: A Randomized Controlled Trial . COPD . 2023 ;Volume 18 . 8. ↵ Harper J , Kearns N , Bird G , Braithwaite I , Eathorne A , Shortt N , Weatherall M , Beasley R . Automatic versus manual oxygen titration using a novel nasal high-flow device in medical inpatients with an acute illness: a randomised controlled trial . BMJ Open Resp Res . 2021 ; 8 ( suppl 1 ). 9. ↵ Decker MJ , Arnold JL , Haney D , et al. Extended monitoring of oxygen saturation in chronic lung disease . Chest . 1992 ; 102 ( suppl 4 ): 1075 – 1079 . OpenUrl CrossRef PubMed Web of Science 10. Sant’Anna T , Donária L , Hernandes NA , et al. Oxygen Desaturation in Daily Life and During a Laboratory-Based Protocol of Activities of Daily Living in COPD: Is There Relationship? Lung . 2018 ; 196 ( suppl 1 ): 19 – 26 . OpenUrl PubMed 11. ↵ Sliwiński P , Lagosz M , Górecka D , et al. The adequacy of oxygenation in COPD patients undergoing long-term oxygen therapy assessed by pulse oximetry at home . Eur Respir J . 1994 ; 7 ( suppl 2 ): 274 – 278 . OpenUrl Abstract / FREE Full Text 12. Soguel Schenkel N , Burdet L , de Muralt B , et al. Oxygen saturation during daily activities in chronic obstructive pulmonary disease . Eur Respir J . 1996 ; 9 ( suppl 12 ): 2584 – 2589 . OpenUrl Abstract / FREE Full Text 13. ↵ Plywaczewski R , Sliwinski P , Nowinski A , et al. Incidence of nocturnal desaturation while breathing oxygen in COPD patients undergoing long-term oxygen therapy . Chest . 2000 ; 117 ( suppl 3 ): 679 – 683 . OpenUrl CrossRef PubMed Web of Science 14. ↵ Hardinge M , Annandale J , Bourne S , et al. British Thoracic Society guidelines for home oxygen use in adults . Thorax . 2015 ; 70 Suppl 1:1 . 15. ↵ Jacobs SS , Krishnan JA , Lederer DJ , et al. Home Oxygen Therapy for Adults with Chronic Lung Disease. An Official American Thoracic Society Clinical Practice Guideline . Am J Respir Crit Care Med . 2020 ; 202 ( suppl 10 ): e121 – e141 . OpenUrl PubMed 16. ↵ Zhu Z , Barnette RK , Fussell KM , et al. Continuous oxygen monitoring--a better way to prescribe long-term oxygen therapy . Respir Med . 2005 ; 99 ( suppl 11 ): 1386 – 1392 . OpenUrl CrossRef PubMed 17. ↵ Schneeberger T , Jarosch I , Leitl D , et al. Automatic oxygen titration versus constant oxygen flow rates during walking in COPD: a randomised controlled, double-blind, crossover trial . Thorax . 2021 ;. 18. Vivodtzev I , L’Her E , Vottero G , et al. Automated O(2) titration improves exercise capacity in patients with hypercapnic chronic obstructive pulmonary disease: a randomised controlled cross-over trial . Thorax . 2019 ; 74 ( suppl 3 ): 298 – 301 . OpenUrl Abstract / FREE Full Text 19. ↵ Kofod LM , Westerdahl E , Kristensen MT , Brocki BC , Ringbæk T , Hansen EF . Effect of Automated Oxygen Titration during Walking on Dyspnea and Endurance in Chronic Hypoxemic Patients with COPD: A Randomized Crossover Trial . JCM . 2021 ; 10 (suppl 21 ). 20. ↵ Kofod LM , Hansen EF , Brocki BC , et al. Optimised oxygenation improves functional capacity during daily activities in patients with COPD on long-term oxygen therapy – a randomised crossover trial. PREPRINT medRxiv . 2024 ;:2024.05.02.24306747. 21. ↵ Byrne AL , Bennett M , Chatterji R , et al. Peripheral venous and arterial blood gas analysis in adults: are they comparable? A systematic review and meta-analysis . Respirology . 2014 ; 19 ( suppl 2 ): 168 – 175 . OpenUrl CrossRef PubMed 22. ↵ Pedersen BS , Kristensen MT , Josefsen CO , et al. Validation of Two Activity Monitors in Slow and Fast Walking Hospitalized Patients . Rehabil Res Pract . 2022 ;2022: 9230081 . 23. ↵ van der Molen T , Willemse BW , Schokker S , et al. Development, validity and responsiveness of the Clinical COPD Questionnaire . Health Qual Life Outcomes . 2003 ; 1 : 13 – 13 . OpenUrl CrossRef PubMed 24. ↵ Kon SS , Dilaver D , Mittal M , et al. The Clinical COPD Questionnaire: response to pulmonary rehabilitation and minimal clinically important difference . Thorax . 2014 ; 69 ( suppl 9 ): 793 – 798 . OpenUrl Abstract / FREE Full Text 25. ↵ Ekström M , Andersson A , Papadopoulos S , et al. Long-Term Oxygen Therapy for 24 or 15 Hours per Day in Severe Hypoxemia . N Engl J Med . 2024 ; 391 ( suppl 11 ): 977 – 988 . OpenUrl PubMed 26. ↵ Nocturnal Oxygen Therapy Trial Group . Continuous or nocturnal oxygen therapy in hypoxemic chronic obstructive lung disease: a clinical trial . Ann Intern Med . 1980 ; 93 (suppl 3 ): 391 – 8 . OpenUrl CrossRef PubMed Web of Science 27. ↵ Long term domiciliary oxygen therapy in chronic hypoxic cor pulmonale complicating chronic bronchitis and emphysema . Report of the Medical Research Council Working Party . Lancet . 1981 ; 1 (suppl 8222 ): 681 – 686 . OpenUrl CrossRef PubMed Web of Science 28. ↵ Habraken JM , ter Riet G , Gore JM , et al. Health-related quality of life in end-stage COPD and lung cancer patients . J Pain Symptom Manage . 2009 ; 37 (suppl 6 ): 973 – 981 . OpenUrl CrossRef PubMed Web of Science 29. ↵ Ståhl E , Lindberg A , Jansson S , et al. Health-related quality of life is related to COPD disease severity . Health Qual Life Outcomes . 2005 ; 3 : 56 – 56 . OpenUrl CrossRef PubMed 30. ↵ Saunders T , Campbell N , Jason T , et al. Objectively Measured Steps/Day in Patients With Chronic Obstructive Pulmonary Disease: A Systematic Review and Meta-Analysis . J Phys Act Health . 2016 ; 13 ( suppl 11 ): 1275 – 1283 . OpenUrl PubMed 31. ↵ Kofod LM , Laursen LB , Westerdahl E , et al. The Experience of Automated Home Oxygen Therapy for Patients with COPD – a Qualitative Study . PREPRINT medRxiv . 2024 ;:2024.11.02.24316557. View the discussion thread. Back to top Previous Next Posted January 25, 2025. Download PDF Data/Code Email Thank you for your interest in spreading the word about medRxiv. NOTE: Your email address is requested solely to identify you as the sender of this article. Your Email * Your Name * Send To * Enter multiple addresses on separate lines or separate them with commas. You are going to email the following Automated Oxygen Delivery in Home Setting for Patients with COPD on Long-Term Oxygen Therapy – a randomized crossover feasibility trial Message Subject (Your Name) has forwarded a page to you from medRxiv Message Body (Your Name) thought you would like to see this page from the medRxiv website. Your Personal Message CAPTCHA This question is for testing whether or not you are a human visitor and to prevent automated spam submissions. Share Automated Oxygen Delivery in Home Setting for Patients with COPD on Long-Term Oxygen Therapy – a randomized crossover feasibility trial Linette Marie Kofod , Ejvind Frausing Hansen , Morten Tange Kristensen , Barbara Cristina Brocki , Elisabeth Westerdahl medRxiv 2025.01.23.25320958; doi: https://doi.org/10.1101/2025.01.23.25320958 Share This Article: Copy Citation Tools Automated Oxygen Delivery in Home Setting for Patients with COPD on Long-Term Oxygen Therapy – a randomized crossover feasibility trial Linette Marie Kofod , Ejvind Frausing Hansen , Morten Tange Kristensen , Barbara Cristina Brocki , Elisabeth Westerdahl medRxiv 2025.01.23.25320958; doi: https://doi.org/10.1101/2025.01.23.25320958 Citation Manager Formats BibTeX Bookends EasyBib EndNote (tagged) EndNote 8 (xml) Medlars Mendeley Papers RefWorks Tagged Ref Manager RIS Zotero Tweet Widget Facebook Like Google Plus One Subject Area Respiratory Medicine Subject Areas All Articles Addiction Medicine (568) Allergy and Immunology (863) Anesthesia (299) Cardiovascular Medicine (4425) Dentistry and Oral Medicine (443) Dermatology (382) Emergency Medicine (607) Endocrinology (including Diabetes Mellitus and Metabolic Disease) (1507) Epidemiology (15221) Forensic Medicine (30) Gastroenterology (1123) Genetic and Genomic Medicine (6588) Geriatric Medicine (667) Health Economics (997) Health Informatics (4524) Health Policy (1368) Health Systems and Quality Improvement (1612) Hematology (540) HIV/AIDS (1264) Infectious Diseases (except HIV/AIDS) (15910) Intensive Care and Critical Care Medicine (1103) Medical Education (623) Medical Ethics (145) Nephrology (667) Neurology (6588) Nursing (346) Nutrition (998) Obstetrics and Gynecology (1143) Occupational and Environmental Health (956) Oncology (3331) Ophthalmology (970) Orthopedics (369) Otolaryngology (420) Pain Medicine (435) Palliative Medicine (129) Pathology (663) Pediatrics (1690) Pharmacology and Therapeutics (691) Primary Care Research (710) Psychiatry and Clinical Psychology (5440) Public and Global Health (9219) Radiology and Imaging (2195) Rehabilitation Medicine and Physical Therapy (1369) Respiratory Medicine (1196) Rheumatology (593) Sexual and Reproductive Health (710) Sports Medicine (529) Surgery (710) Toxicology (99) Transplantation (289) Urology (265) (function(){function c(){var b=a.contentDocument||a.contentWindow.document;if(b){var d=b.createElement('script');d.innerHTML="window.__CF$cv$params={r:'9ffa44f5bf3558d3',t:'MTc3OTQzNjYzOQ=='};var a=document.createElement('script');a.src='/cdn-cgi/challenge-platform/scripts/jsd/main.js';document.getElementsByTagName('head')[0].appendChild(a);";b.getElementsByTagName('head')[0].appendChild(d)}}if(document.body){var a=document.createElement('iframe');a.height=1;a.width=1;a.style.position='absolute';a.style.top=0;a.style.left=0;a.style.border='none';a.style.visibility='hidden';document.body.appendChild(a);if('loading'!==document.readyState)c();else if(window.addEventListener)document.addEventListener('DOMContentLoaded',c);else{var e=document.onreadystatechange||function(){};document.onreadystatechange=function(b){e(b);'loading'!==document.readyState&&(document.onreadystatechange=e,c())}}}})();
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.