Reaction of arterial and venous branches of the broad ligament of the rat uterus to low-intensity red laser irradiation

In: Bulletin of Experimental Biology and Medicine · 2021 · vol. 172(9) , pp. 372–375 · doi:10.47056/0365-9615-2021-172-9-372-375 · W3204909216
OA: closed CC0
Full text JSON View on OpenAlex View at publisher
⚙ AI-generated summary by qwen3.7-flash+body, 2026-09-29 ⓘ

Biomicroscopy of rat uterine broad ligament vessels revealed that small arteries exhibit greater sensitivity to low-intensity red laser irradiation than veins, likely due to morphological and hemodynamic differences.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

⚙ AI-generated deep summary by qwen3.7-flash, 2026-09-29 · read from full text ⓘ

This study utilized biomicroscopy to examine the vascular responses of the broad ligament in female rats following exposure to low-intensity red helium-neon laser irradiation. The researchers found that small arteries exhibited the highest sensitivity to the laser, while veins demonstrated significantly lower reactivity compared to arterial vessels. These differences in response were attributed to inherent morphological, functional, and hemodynamic distinctions between the two vessel types. The paper does not explicitly discuss endometriosis or adenomyosis; it was included in the corpus via a keyword match in the upstream search index.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Full text 1,767 characters · extracted from oa-doi-fallback · click to expand
Содержание и архив номеров 2021 г., Том 172, № 9 СЕНТЯБРЬ Морфология и патоморфология Реакция артериальных и венозных ветвей широкой связки матки крысы на низкоинтенсивное лазерное облучение красной области спектра Методом биомикроскопии изучали реакцию артериальных и венозных сосудов широкой связки матки беспородных крыс-самок на излучение гелий-неонового лазера с длиной волны 632.8 нм и выходной мощностью 2 мВт. Наибольшей чувствительностью к лазерному облучению обладали мелкие артерии. Вены широкой связки матки характеризовались меньшей реактивностью на соответствующее по времени облучение, чем артериальные сосуды, что, по-видимому, связано с морфологическими, функциональными и гемодинамическими различиями в свойствах рассматриваемых сосудов. Ключевые слова: сосуды широкой связки матки; витальная микроскопия; гелий-неоновый лазер Адрес для корреспонденции: [email protected] Черток А.М. DOI: 10.47056/0365-9615-2021-172-9-372-375 Reaction of arterial and venous branches of the broad ligament of the rat uterus to low-intensity red laser irradiation Using the biomicroscopy method, arterial and venous vessels of the broad ligament of the uterus of mongrel female rats were studied for exposure to radiation from a helium-neon laser with a wavelength of 632.8 nm and an output power of 2 mW. It is shown that the most sensitive to laser irradiation are mainly small arteries. The veins of the broad ligament of the uterus have less reactivity to the effect of laser irradiation corresponding to the time than arterial vessels, which is apparently due to morphological, functional and hemodynamic differences in the properties of the vessels under consideration. Key Words: vessels of the broad ligament of the uterus; vital microscopy; helium-neon laser

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

⚙ Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback ⓘ

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

openalex
last seen: 2026-06-10T17:14:06.276822+00:00
License: CC0 · commercial use OK