Einsatz des dreidimensionalen Ultraschalls zur Lagekontrolle bei Intrauterinpessaren

In: Ultraschall in der Medizin · 2001 · vol. 22(02) , pp. 75–80 · doi:10.1055/s-2001-12852 · PMID:11398504 · W2046461813
article OA: closed CC0 ⤵ 1 in-corpus citation
View on OpenAlex View on PubMed View at publisher
AI-generated summary by claude@2026-06, 2026-06-13

This prospective study found that 2D and 3D ultrasound are equally accurate for measuring IUD placement, but 3D ultrasound provides superior visualization of LNG IUDs and uterine anomalies.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

AIM OF THE STUDY: The purpose of our prospective study was to assess the accuracy of measuring and visualizing different types of IUDs with three dimensional ultrasound (3D) and two dimensional ultrasound (2D). METHODS: Ultrasound investigation was carried out in 147 patients 6 weeks after insertion of the IUD; in 127 cases a copper IUD was inserted, in 20 cases a Levonorgestrel-containing (LNG) IUD. Correct measurement was defined as the distance between top of the IUD and inner endometrium as well as IUD and myometrium (fundus) in the longitudinal plane (2D) plus the frontal plane (3D). The possibility to visualize the complete IUD was evaluated in the frontal plane and in the transparent mode after volume rendering. RESULTS: The distance measurement between copper IUD and myometrium or endometrium with 2D and 3D did not differ significantly (19.54 mm +/- 6.13 vs. 19.48 +/- 6.39, 5.58 +/- 4.57 vs. 5.21 +/- 4.57). There was no difference in the distance between LNG IUD and myometrium between the two ultrasound investigations (17.75 +/- 3.70 vs. 16.80 +/- 4.65), whereas the distance between LNG IUD and endometrium was significantly different (5.00 +/- 2.81 vs. 4.30 +/- 3.06, p = 0.03). The imaging of the LNG IUD was very clear with the 3D facilities, especially in the transparent mode. Furthermore, congenital anomalies of the uterus, like an arcuate uterus, were clearly detectable in the frontal plane (3D). CONCLUSION: Distance measurement can be obtained equal as well by 2D or 3D ultrasound. The 3D ultrasound offers the advantage of better visualization of LNG IUD and the assessment of anomalies of the uterine cavity.

My notes (saved in your browser only)

Citation neighborhood (sparse)

Too few in-corpus citations on either side for a chart; here are the lists.

Cited by (1)

Cited by (1)

Source provenance

openalex
last seen: 2026-05-11T06:21:44.532445+00:00
License: CC0 · commercial use OK