Finite Element Analysis of Welded Titanium Bar and Poly Ether Ether Ketone Bar in Maxillary Full Arch Splinted Interim Prosthesis

preprint OA: closed
Full text JSON View at publisher
Full text 138,242 characters · extracted from preprint-html · click to expand
Finite Element Analysis of Welded Titanium Bar and Poly Ether Ether Ketone Bar in Maxillary Full Arch Splinted Interim Prosthesis | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Article Finite Element Analysis of Welded Titanium Bar and Poly Ether Ether Ketone Bar in Maxillary Full Arch Splinted Interim Prosthesis Lamia Farouk Zaki Mohamed, Hebatallah Tarek Mohamed, Hany Ibrahim Eid, and 2 more This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-5183274/v1 This work is licensed under a CC BY 4.0 License Status: Published Journal Publication published 09 May, 2025 Read the published version in Scientific Reports → Version 1 posted 6 You are reading this latest preprint version Abstract Background Full arch fixed provisional restorations are prone to fracture during function for several reasons. Those types of fractures during the healing period eliminate the cross-arch stabilization and disrupt stress distribution patterns. Methods FEA (Finite Element Analysis) study was carried out using edentulous maxillary models where implants and other components were represented in three dimensional (3D) geometric models. Two 3D FEA models with six implants were used. Model TB: the implants were splinted with welded titanium bar; Model PB: the implants were splinted with PEEK (Poly Ether Ether Ketone) bar. An interim full arch PMMA (Poly methyl methacrylate) prosthesis was virtually designed for both models. Both models were subjected to vertical and oblique forces with a single force magnitude of 100 N. The amount of maximum equivalent Von-Mises stresses was calculated at the cervical part of the bone cylinder (marginal bone) and both frameworks. Results Under bilateral vertical loading, stresses were found to be comparable at the marginal bone between titanium and PEEK splinting. The PEEK framework had better and lower stress distribution than the titanium. While under unilateral oblique forces PEEK had better mechanical response on the marginal bone. And PEEK framework itself showed higher stresses than the titanium. Conclusion The behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability Health sciences/Medical research Physical sciences/Materials science Immediate loading framework splinting PEEK intraoral welding Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Background Rehabilitation of edentulous patients with an implant-supported prosthesis typically involves the placement of implants and then, loading the prosthesis after 3–4 months in the mandible and 6–8 months in the maxilla [ 1 ]. Such a stress-free healing period permits the osseointegration of the implant, lowering the risk of implant failure and loss [ 2 ]. Two-stage protocol showed significant psychological and functional difficulties for patients who have recently extracted their remaining teeth never worn a removable prosthesis, since they must wear an interim removable prosthesis. Accordingly, the original two-stage protocol has been altered where implants were placed after immediate tooth extraction along with the immediate placement of a fixed interim prosthesis [ 3 ]. Interim prostheses have several advantages, including serving as a diagnostic tool, helping evaluation of peri-implant soft tissue, evaluation of neighboring teeth, and evaluation of the patient’s oral hygiene. They also are helpful for patient management (esthetic, phonetic, psychological), communication between patient, prosthodontist, and technician, determination for implant site development, healing of the soft tissue around the implants, potentially loading the implants, improving tissue contours related to emergence profile, and developing of an interdental or papillae, and therefore potential avoidance of a third surgical procedure [ 4 , 5 ]. According to Lin et al., the most common complications associated with an interim full-arch fixed acrylic resin prosthesis are the fracture of the prosthetic structure and fracture of the veneering material [ 6 ]. Such fracture during the healing period eliminates cross- arch stabilization and disrupts stress distribution patterns [ 7 ]. Several reasons have made the full arch fixed Interim prostheses susceptible to fracture during function, acrylic porosities and/or foreign materials embedded in the acrylic as “Air pockets” have been observed in the cracked acrylic bases of many restorations [ 8 ]. It was reported that flexural fatigue, which occurred after repeated flexing of the PMMA prosthesis, could also lead to fractures [ 9 ]. Splinting (rigid or non-rigid) has been shown to prevent axial rotation and movement of immediately loaded implants. However, the effectiveness of splinting to promote implant osseointegration was found to be uncertain since previous studies have shown osseointegration of un-splinted immediately loaded implants [ 10 ]. According to some studies, splinting of implants reduces the risk of overload to each implant because of the increased surface area and enhanced biomechanical distribution [ 11 , 12 ]. Splinting could be either rigid by a metal bar or semi-rigid with acrylic resin. The semi-rigid splinting can be fabricated by CAD/CAM technology at the correct vertical dimension of occlusion before an immediate load, or the patient's pre-existing denture can be used after adjusting it to serve as a fixed interim prosthesis [ 13 ]. Semi-rigid splinting doesn’t provide adequate stress reduction on the bone surrounding the implants. On the other hand, it offers better passivity to the implant- supported fixed prosthesis because of the lack of a metal support. Accordingly, semi-rigid splinting has been recommended for the healing period after implant placement (4–6 months), which is important for implant survival [ 14 ]. Several studies reported successful oral rehabilitation of edentulous maxilla and mandible with a fixed definitive restoration supported by an intra-orally welded titanium wire on the same day of implant placement surgery [ 15 ]. The intra-oral welding technique allows rigid splinting of multiple implants for immediate loading on the same day, thus ensuring a predictable fixation of implants in the healing period with a considerable reduction in the micro-movements [ 16 ]. Intraoral welding was reported to be a technique sensitive procedure. It is crucial to have total contact between the welding abutment and the titanium bar during the welding procedure, a perfect joint mandate the application of firm and constant pressure [ 17 ]. Furthermore, there are more limits to syncrystallization and electric resistance welding, since they are not efficient on every kind of metal and alloy, and these cannot be utilized on patients with pacemakers [ 16 ]. Polyetheretherketone (PEEK) is a high-performance polymer belonging to the polyaryletherketone group, it has excellent physical and chemical properties as low specific weight (1.3 g/cm3) and low flexural strength (165–170 MPa), proper elasticity (3,600 MPa), and suitable hardness (20 HV) [ 18 , 19 ]. The main beneficial feature of this material is the reduced modulus of elasticity than that of the metallic materials and is relatively comparable to that of the human bone, hence minimizing the stress on the surrounding bone [ 20 ]. In their finite element study to examine the behavior of polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) prosthetic frameworks, Villefort RF et al [ 21 ] reported that the superior shock absorbance of PEKK has led to a reduced stress concentration on the prosthetic screw and prosthetic base. This showed clinically a decreased risk of fracture on the acrylic base and screw loosening. It was reported that the clinical service life of implant prosthesis is influenced by the load transfer between the implant and alveolar bone [ 22 ]. Moreover, studies on traditional implants have demonstrated that stress concentration is prevalent in the marginal cortical bone corresponding to the neck of the implant [ 23 ]. This stress overload maximizes the risk of marginal bone resorption around the implant [ 24 ]. Since marginal bone quality is a critical parameter controlling the osteo-mechanical behavior in implant biomechanics [ 25 ]. Finite element model is a computer technique for stress distribution analysis that has been used for making virtual models. The influence of loading strengths over peri-implant and dental implant elements can be recorded by applying the equivalent stress (von Mises stress) expressed in Megapascals (MPa) [ 26 ]. The finite element analysis (FEA) study has significant clinical implications, as it offers a helpful understanding of the biomechanical behavior of the splinting materials. Additionally, it would help in predicting the reaction of these materials under various loading conditions. [ 27 ] Consequently, improving the long-term clinical stability of the implant system and the overall performance. Moreover, FEA has been shown to be an applicable method for analyzing the distribution of stress and clinical behavior of geometrically complex prosthetic systems that include dental implant, bone, and prosthesis [ 28 ], accordingly, clinicians will be able to identify areas of high stresses that may cause bone loss or future implant failure and therefore, they can follow better planning and maintenance protocols. [ 21 ] This can definitely improve the clinical decision-making, the treatment outcomes, hence reduce the risk of complications. So, the applications of theses FEA studies can guarantee a safe and effective real clinical applications Even with all these benefits, FEA studies comprise a number of limitations. The loads tend to be more simplified than the actual complex forces encountered during mastication and various other functions. [ 29 ], in addition, they can’t fully capture the nature of the anatomical structures as the bone or the soft tissues. Bone is an incredibly complicated living structure and its characteristics vary from individual to individual. In addition, the use of FEM when studying the extremely accurate anatomy of a bone structure may limit the analysis to that particular structure. [ 30 ] Moreover, FEA is not time-dependent. Biological dynamics of a living component cannot be modeled with precision as it is difficult to take factors like time and other factors the structure is subjected to in accounts. And to obtain a high quality FEA, a specialized software is needed which may not be available to all researches. [ 31 ] Thus, the purpose of this study was to evaluate the mechanical behavior of maxillary full arch loaded interim prostheses fabricated using different splinting materials. The null hypothesis was that the use of different splinting materials would not affect the prosthesis’ mechanical behavior. Methods The current study included two steps: virtual model construction and three-dimensional Finite Element Analysis. Two virtual models were made in this study. Both with six implants are used. In model TB, the implants were splinted with welded titanium bar; however, in model PB, the implants were splinted with PEEK bar. Model construction For virtual model construction, an educational maxillary edentulous cast (Ramses medical products, Cairo, Egypt) was used. It was scanned using 3D scanner (CeraMap 400 Amann Girrbach America Inc., Koblach, Austria) and modelled using Exocad software (Exocad DentalDB 3.1 Rijeka CAD/CAM software) (Exocad America, Inc. Darmstadt, Germany). As (D3) bone density is often observed in the maxilla, the cast was virtually formed to represent a 1 mm outer cortical bone covering the trabecular bone (Fig. 1 .a). Reverse Engineering was made to the cast and exported in Standard Tessellation Language (STL) file. This STL virtual cast was imported into the Mesh Mixer software (Version 3.5.0) (Mesh Mixer, Autodesk, San Rafael, California, United States of America) for further smoothening, gap filling and exported as STL format [ 32 ]. For the bone cylinder, a new plane was created parallel to the top plane, and a split was made in the top part of the cylinder along the new plane to facilitate collecting the results from the marginal peri-implant bone. Therefore, the marginal peri-implant bone is 2 mm height and 1.3 mm thickness [ 33 ]. Six dental implants were planned to be placed in the right lateral incisor R2, right first premolar R4, right first molar R6, left central incisor L1, left canine L3, left first molar L6. All implants were placed axially [ 34 ]. The implants were modelled using the Solidworks software (2023 SP0 software) (Solidworks 2023 x64 Edition premium package) with 4.2 mm diameter and a 10 mm length [ 35 – 37 ] (Fig. 1 .b). Straight Multiunit abutments and titanium bases were also modelled using the Solidworks software (Fig. 1 , c and d). In model TB, the implants were splinted with titanium bar of 2mm thickness [ 16 ] (Fig. 1 .e) while in model PB, the implants were splinted with PEEK bar of 3mm thickness [ 21 , 38 ] (Fig. 1 .f). All other components of both models were identical to standardize all the variables. The prosthetic superstructure was designed using Exocad software (Exocad DentalDB 3.1 Rijeka CAD/CAM software) (Exocad America, Inc. Darmstadt, Germany) to be in the form of full arch PMMA prosthesis [ 39 ] (Fig. 1 .g). The STL files of the dental implants, abutments and prosthetic superstructure were assembled by Solidworks software. Straight multiunit abutment with 5 mm diameter was exported as STL file from BlueSky Plan version 4.12.13 (64 bit) (Bio software, LLC). The STL file was then exported to Solidworks and was reversed engineered to form a 3D cast model [ 32 ]. For the titanium sleeves, a 2D sketch of circle with 5 mm diameter was drawn in the top plane of the cap part. This circle was extruded using boss extrude tool to form a cylinder of 8 mm length. Finally, a cavity was made inside the cap part and the cylindrical part to form the final 3D hollow Titanium sleeve [ 32 ]. The two models were exported to ANSYS software (Ansys 2022 R1) (Ansys, Inc, Pennsylvania, USA) to start the analysis process, the cervical part of each bone cylinder was assumed to be compact bone and the remaining part of the bone cylinder was assumed to be cancellous bone. The implant, multi-unit abutment, temporary titanium sleeves and the metal wire are all assumed to be made from titanium alloy. The PEEK framework was assigned to be made from BioHPP PEEK. While all the conversion prosthesis was assumed to be made from PMMA. The materials were assumed to have linear isotropic behavior and the modulus of elasticity and Poisson's ratio for the different component materials used in the study are listed in the table below, Table 1 . All components were constructed in a way that assures 100% contact along the interfaces. Table 1 legend: properties of each component in the model Table 1 component properties Material Modulus of elasticity (MPa) Poisson’s ratio Compact bone 15,000 0.3 Cancellous bone 1,500 0.3 PMMA 2,770 0.35 Titanium Alloy 110,000 0.3 PEEK 4,200 0.38 Meshing the models were done by subdividing the geometric model into small pieces called elements connected at common points called nodes. (Fig. 2 ). The total number of elements in the model TB was 139733 and in the model PB was 147951. However, the number of nodes in the model TB was 139733 and in the model PB was 268653.The fixed restraints were applied to the inferior aspect and to all the lateral aspects of the maxillary virtual cast to avoid any bodily displacement during loading. Load application Two loading scenarios were applied [ 33 , 40 , 41 ]. The first scenario simulated a Vertical Load of 200 N that was applied bilaterally in the posterior region where the first molar tooth received load of 100 N and each premolar received 50 N load (Fig. 3 .a). The vertical load was applied on the central fossae of the premolar and the first molar. The second scenario simulated an Oblique (Lateral) Load of 200 N was applied unilaterally in the posterior region of the right side where The first molar tooth received load of 100 N and each premolar received 50 N load (Fig. 3 .b). Lateral load was applied to the lingual inclines of the buccal cusps of the premolar and first molar with an angle of about 45 degrees to the vertical axis of the tooth. In both models, the stresses displayed are the maximum principle stress for the (1) cervical part of the bone cylinder (marginal bone) (Fig. 4 .a and b, Fig. 5 .a and b). and (2) titanium wire (Fig. 4 .c and Fig. 5 .c). and PEEK framework (Fig. 4 .d and Fig. 5 .d) In both models, the strain displayed for the (1) cervical part of the bone cylinder (marginal bone) under vertical load (Fig. 6 .a and b). and (2) cervical part of the bone cylinder (marginal bone) under oblique load (Fig. 6 .c and Fig. 6 .d). They were displayed as graphical output in the form of color coded maps and numeric output that displayed the amount of the maximum equivalent stresses (Von-Mises stresses) in Megapascal (Mpa) [39, 40]. Then, the results were collected from both models and tabulated. Results The results of this study showed that under bilateral vertical load, the marginal bone stresses at the left and right molars were 15.07 &14.485 MPa receptively for Model TB (titanium framework), and 14.977& 14.927 MPa receptively for Model PB (PEEK framework). The results recorded were comparable in both models. Moreover, it was found that under bilateral vertical load, PEEK framework had better distribution and lower stresses than titanium framework. The stresses were 8.3313 and 54.924 MPa in PEEK and titanium frameworks respectively Table 2 . This may be contributed to the connection between PEEK bar and abutments. Regarding the stresses on the implants, it was found that the results in Model TB are slightly higher than that in Model PB, and this may be contributed to the shock absorbing nature of PEEK that tends to dissipate stresses under the bilateral vertical load which accordingly transmits less stresses to the implants. Table 2 Equivalent (von-Mises) Stresses in case of Bilateral Vertical Load Bilateral Vertical Loading Marginal bone PEEK titanium left first molar left canine left central right lateral right first pre-molar right first molar left first molar left canine left central right lateral right first pre-molar right first molar 14.9 MPa 17.5 MPa 4.5 MPa 4.1 MPa 13.3 MPa 14.9 MPa 15.1 MPa 18.5 MPa 5.6 MPa 4.7 MPa 13.3 MPa 14.4 MPa Dental implants 55 MPa 25 MPa 10.8 MPa 17.9 MPa 43 MPa 71.4 MPa 58.7 MPa 25.8 MPa 14.4 MPa 18.5 MPa 45.9 MPa 73.2 MPa framework 8.3 MPa 54.9 MPa PEEK, polyetheretherketone. MPa: Mega Pascal unit. Table 2 legend: Comparison of the maximum recorded stress values in the marginal bone and the framework between the models PB and TB during the bilateral vertical loading scenario. Under unilateral oblique forces, the marginal bone stresses at the left and right molars were 3.9284 &173.94 MPa receptively for Model TB. Whereas for Model PB, they were found to be 4.1725&166.84 MPa respectively. PEEK is showing better mechanical response compared to titanium framework. While PEEK framework showed higher stresses than the titanium framework. The stresses were 168.18 &106.03 MPa respectively. And again, this may be contributed to the nature of the connection between PEEK bar and abutments Table 3 . In regards to the stresses on the implants, it was found again that the results in Model TB are higher than that in Model PB, and this may be caused by the nature of PEEK under the oblique load that tends to accumulate the stresses within the PEEK itself transmitting less stresses to the implants. Table 3 Equivalent (von-Mises) Stresses in case of Unilateral Oblique Load Unilateral oblique load Marginal bone PEEK titanium Left first molar Left canine Left central Right lateral Right first pre-molar Right first molar Left first molar Left canine Left central Right lateral Right first pre-molar Right first molar 4.1 MPa 11.1 MPa 37.1 MPa 46.7 MPa 126.4 MPa 166.8 MPa 3.9 MPa 16.6 MPa 43.5 MPa 51 MPa 128.9 MPa 173.9 MPa Dental implants 9.7 MPa 30 MPa 100.2 MPa 184.4 MPa 484.4 MPa 699.4 MPa 10.2 MPa 38 MPa 113.5 MPa 186.6 MPa 508 MPa 715 MPa framework 168.1 106 PEEK, polyetheretherketone. MPa: Mega Pascal unit. Table 3 legend: Comparison of the maximum recorded stress values in the marginal bone and the framework between the models PB and TB during the unilateral oblique loading scenario Regarding the strain, it was found that that under bilateral vertical load, the marginal bone strain at the left and right molars were 8.90 &9.66 mm/mm MPa receptively for Model TB (titanium framework), 9.98 &9.95 mm/mm receptively for Model PB (PEEK framework). The results recorded were comparable in both models. Table 4: Equivalent Elastic Strain (mm/mm) in case of Bilateral Vertical Load Bilateral Vertical Loading Marginal bone PEEK titanium Left first molar Left canine Left central Right lateral Right first pre-molar Right first molar Left first molar Left canine Left central Right lateral Right first pre-molar Right first molar 9.98 mm/mm 1.17 mm/mm 3.06 mm/mm 2.71 mm/mm 8.9 mm/mm 9.95 mm/mm 8.90 mm/mm 1.24 mm/mm 3.74 mm/mm 3.18 mm/mm 8.88 mm/mm 9.66 mm/mm PEEK, polyetheretherketone. Table 4 legend: Comparison of the maximum recorded strain values in the marginal bone between the models PB and TB during the bilateral vertical loading scenario. While under unilateral oblique forces, the marginal bone strain at the left and right molars were 2.621 &1.166 mm/mm receptively for Model TB. Whereas for Model PB, they were found to be 2.78 &1,11 mm/mm respectively. The results recorded were comparable in both models. Table 5 Equivalent Elastic Strain(mm/mm) in case of Unilateral Oblique Load Unilateral oblique load Marginal bone PEEK titanium Left first molar Left canine Left central Right lateral Right first pre-molar Right first molar Left first molar Left canine Left central Right lateral Right first pre-molar Right first molar 2.78 mm/mm 1.38 mm/mm 2.48 mm/mm 3.12 mm/mm 8.43 mm/mm 1.11 mm/mm 2.62 mm/mm 1.11 mm/mm 2.90 mm/mm 3.40 mm/mm 8.60 mm/mm 1.16 mm/mm PEEK, polyetheretherketone. Table 5 legend: Comparison of the maximum recorded strain values in the marginal bone between the models PB and TB during the unilateral oblique loading scenario DISCUSSION The present study evaluated the stress distribution along the marginal bone using two different splinting materials under vertical and oblique loads. The results showed that both splinting materials have different mechanical responses, thus, the null hypothesis was rejected. The clinical evaluation of the stress and strain distribution in peri-implant bone areas is difficult and not feasible in most situations. Thus, FEA is an appropriate method for evaluating the distribution of stresses and clinical performance of geometrically complex prosthetic systems that include dental implant, bone, and prosthesis [ 28 ]. As the study that ran by Altıparmak et al., where three - dimensional finite element analysis was used to examine the stresses that occur under occlusal forces on the bone, and the implant systems made of Titanium and Polyether ether ketone (PEEK) material [ 42 ]. Since FEA is a simulation, increasing the mesh density in the regions to be evaluated on the model improved the data accuracy. Like previous finite element analysis studies related to implantology research, our study assumed that all modeled structures are in constant contact with each other [ 43 ]. Regarding the influence of the number of implants on the structure, it is proved that the placement of six implants distribute stresses more evenly. In a study conducted by Fazi et al. [ 44 ] the stress distribution in 3-4-5 implant-supported prosthesis was investigated and it was found that load accumulation on the system declined with 5 implant-supported prosthesis. In a recent study by Desai et al. [ 40 ], two loading forces were applied, bilateral vertical forces which represented a clenching situation, and the unilateral which simulated the masticatory forces. In order to simulate the mean posterior bite force values, a vertical load of 200 N (50 N for each premolar and 100 N for the first molar) was applied on the central fossae of the premolars and the first molar. On the other hand, the oblique load was applied to the lingual inclines of the buccal cusps of the premolars and the first molar with an angle of about 45 degrees to the vertical axis. This is consistent with the studies done by Osman et al, and Hassan et al. [ 33 , 41 ]. Also, Meric et al. [ 45 ], showed that materials used in the fabrication of dental prostheses can influence the loading of dental implants and may potentially lead to bone deformation. Assunção et al. [ 46 ], concluded that the use of rigid framework materials in implant supported prostheses increased the amount of stress on dental implants. Unlike the study conducted by Dayan et al. [ 47 ], which concluded that the fabrication of frameworks from rigid materials in All-on-4 prostheses reduces stress in dental implants and peri-implant bone when the distal implants are tilted 30°. Other studies, as the one performed by Çiftçi and Canay [ 48 ], and the study ran by Sertgöz [ 49 ], where they reported that the use of less rigid restorative materials resulted in high stress in dental implants and supporting tissues. Garg J [ 17 ], demonstrated that rigid framework splinting obtained by intraoral welding, can control the micro-movements in immediate loading protocols and decrease the mechanical stresses exerted on each single implant, accordingly, assuring an optimal distribution of occlusal load and reducing the lateral forces on healing implant. Although, some studies as the one performed by Aboelnagga M, where it was concluded that using polyether-ketone-ketone (PEKK) for constructing the framework of prosthesis led to favorable stress distribution and reduction of stresses induced to supporting implants [ 50 ]. Also, El-Rahman A et al. [ 51 ], studied the behavior of PEEK bar under cyclic loading, where it exerted less strain and showed favorable load distribution around the implants and on the ridge areas. The data of this study showed that the intensity and distribution of the equivalent stresses, in unilateral oblique loads, in the PEEK framework were higher than the Ti frameworks. While under bilateral vertical load the intensity and distribution of the equivalent stresses were higher in Ti frameworks. This might give a speculation of an improved load distribution along the PEEK framework in model PB compared to model TB. Such a speculation might be related to the shock absorption and low elastic modulus of PEEK. The findings of this study coincide with the study done by Ersöz and Mumcu [ 52 ], and Jaros et al. [ 53 ], which showed that PEEK responded differently under oblique and axial load; as under oblique loading PEEK accumulated stresses instead of distributing it, in contrast to the stiffer CoCr, ZrO2 and Ti. This is based on the material’s ability for shock absorption and the low elastic modulus. Also, the study done by Elkhooly AS et al., examined the pattern of stress distribution along PEKK and Bio-HPP CAD-CAM bar materials in implant-supported prostheses. They found that under unilateral loads, the strains concentrated at the loaded implants and ridge leading to statistically significantly larger mean micro-strains on the loaded side compared to the unloaded side [ 54 ]. In accordance to our study, Yu et al. [ 55 ] reported that compared to polymeric frameworks, zirconia and metals caused lower stresses on bone and implant, and greater stresses on framework. It was reported that the biomechanical qualities of high elastic modulus materials made them more appropriate for implant-supported prostheses frameworks [ 56 ]. A three-dimensional finite element analysis study done by Shin et al. [ 57 ], concluded that the framework with the low elastic modulus (PEKK) reduced the stress within the framework; however, it transmitted additional stress to the supra-structures of the prostheses and this was consistent with the finding of this study. Similarly, Tribst et al. [ 58 ] concluded that an increase in the elastic modulus of the framework decreased the stress transmitted to the implants and surrounding bone. In the study done by Shetty et al. [ 59 ] where full-arch implant supported prosthesis was evaluated with different frameworks by strain gauge analysis, PEEK demonstrated higher deformation values than ZrO2 and CoCr in the presence of cantilever which coincide with the finding of this study. In contrast to our study, Franco et al. [ 60 ] reported that the cross section of the PEEK splint has its effect on the response to the applied stresses. However, in this study the cross section effect wasn’t evaluated. Regarding the clinical relevance, and based on the current study results, the biomechanical properties and behavior of the PEEK splint qualifies it to be used with the provisional restoration, keeping in mind that PEEK response to oblique load tends to accumulate rather than dispense the stresses along the splint body, so the usage of cantilever is not advised in such a case to avoid the risk of bending or even fracture of the splint. Additionally, the design of the implant platform, occlusal forces pattern, implant number and diameter have their effect on the pattern of the stress transmission [ 61 ]. Though standardization and variables control can be obtained from finite element analysis studies. Yet, this study has many limitations. Static loading was applied for the purpose of simplification whereas loading is dynamic during the normal chewing functions. Moreover, it was proposed that all dental implants were fully Osseointegrated with bone, however, this does not mimic the clinical situation. And, the material properties of the bone were proposed to be linearly elastic and isotropic, however, this does not coincide with the living tissue simulation [ 32 ]. CONCLUSION Within the limitations of our study and the outcomes obtained, it was concluded that the behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability Abbreviations STL: Standard tessellation language; SEqv: Equivalent stresses; Von‑Mises stress; spread; N: Newton; MPa: Mega Pascal, PEEK: polyetheretherketone. Declarations Clinical trial number Not applicable. Acknowledgements Not applicable. Author contributions LFZM: Conceptualization, methodology, writing—original draft, writing— review and editing, data curation.HTM: writing—review and editing, data curation.HIE: writing—review and editing, software, analysis SSM: Methodology, software, analysis, writing—review and editing. RMA: Conceptualization, methodology, writing original draft, writing—review and editing, data curation All authors have read and approved the manuscript. Funding Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB). Availability of data and materials All data generated or analyzed during this study are provided within the manuscript. Ethics approval and consent to participate Not applicable Consent for publication Not applicable. Competing interests The authors of the current study declare that they have no competing interests Author details 1 Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo 11561, Egypt. 3 Oral and Maxillofacial Prosthodontics department. School of Dentistry, NewGiza University. Giza, Egypt References Weerapong K, Sirimongkolwattana S, Sastraruji T, Khongkhunthian P . Comparative study of immediate loading on short dental implants and conventional dental implants in the posterior mandible: A randomized clinical trial. INT J ORAL MAX IMPL. 2019;34(1). Zhang S, Wang S, Song Y.2017.Immediate loading for implant restoration compared with early or conventional loading: A meta-analysis. J Craniomaxillofac Surg. 45(6):793–803. Schnitman PA, Wohrle PS, Rubenstein JE . Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results. J ORAL IMPLANTOL. 1990;16(2):96-105. Lin WS, Ercoli C: A technique for indirect fabrication of an implant-supported, screw-retained, fixed provisional restoration in the esthetic zone. J Prosthet Dent 2009;102:393-396 Conte GJ, Fagan MC, Kao RT: Provisional restorations: a key determinant for implant site development. J Calif Dent Assoc 2008;36:261-267 Lin WS, Eckert SE. Clinical performance of intentionally tilted implants versus axially positioned implants: A systematic Review. Clin Oral Implants Res. 2018;29(3):78-105. Hassan NA, Elkhadem AH, Kaddah A, El Khourazaty NS. Prosthesis and implant survival in immediately loaded full arch restorations using fiber-reinforced versus non-reinforced temporary frameworks: a randomized clinical trial. Brazilian Dental Science. 2022;25(3) Singh S, Palaskar JN, Mittal S . Comparative evaluation of surface porosities in conventional heat polymerized acrylic resin cured by water bath and microwave energy with microwavable acrylic resin cured by microwave energy. Contemp. Clin. Dent.2013;4(2):147-51. Banerjee R, Banerjee S, Prabhudesai PS, Bhide SV.Influence of the processing technique on the flexural fatigue strength of denture base resins: An: in vitro: investigation. Indian J Dent Res.;21(3):391-5. Korsch M, Walther W, Hannig M, BartolsA.Evaluation of the surgical and prosthetic success of All-on-4 restorations: a retrospective cohort study of provisional vs. definitive immediate restorations. Int. J. Implant Dent.2021;7:1-1. Clelland NL, Lee JK, Bimbenet OC, Brantley WA.A three‐dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. J Prosthodont . 1995;4(2):95-100. Maló P, de Araújo Nobre M, Petersson U, WigrenS.A pilot study of complete edentulous rehabilitation with immediate function using a new implant design: case series. Clin Implant Dent Relat Res. 2006;8(4):223-32. Lee HJ, de Mattias Sartori IA, Alcântara PR, Vieira RA, Suzuki D, Fontão FG, Tiossi R . Implant stability measurements of two immediate loading protocols for the edentulous mandible: rigid and semi-rigid splinting of the implants. Implant Dent. 2012;21(6):486-90. Fayyad A.Prosthetic complications in immediately loaded All-on-Four mandibular prosthesis using titanium wire reinforcement versus non reinforced temporary framework. A Randomized Clinical Trial. Egypt. Dent. J.2022;68(1):885-92. Fogli V, Camerini M, Lauritano D, Carinci F.Success and high predictability of intraorally welded titanium bar in the immediate loading implants. Case Rep. Dent. 2014;2014(1):215378. Shetty M, Hegde R, Adarsh N, Prabhu A. Immediate Rehabilitation of Edentulous Maxilla with a Definitive ProsthesisUtilizing an Intraorally Welded Titanium Framework. RGUHS J. Med. Sci. 2022;12(1). Garg J, Dhawan P. Intraoral welding: A concept of immediate rehabilitation of edentulous arches-a primer. J. Prosthet. Implant Dent. 2020; 3(1):83. Toth JM. Biocompatibility of Polyaryletheretherketone Polymers. PEEK Biomaterials Handbook. 2012, p. 81-92. Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials. 2007;28:4845-69. Stawarczyk B, Eichberger M, Uhrenbacher J, Wimmer T, Edelhoff D, Schmidlin PR. Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J. 2015;34:7-12. Villefort RF, Diamantino PJ, Von Zeidler SL, Borges AL, Saavedra GD, Tribst JP. Mechanical response of PEKK and PEEK as frameworks for implant-supported full-arch fixed dental prosthesis: 3D finite element analysis. Eur. J. Dent. 2022;16(01):115-21. Suedam V, Moretti Neto RT, Sousa EA, Rubo JH. Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures. J. Appl. Oral Sci. 2016;24:114-20. Dos Santos MB, Da Silva Neto JP, Consani RL, Mesquita MF. Three‐dimensional finite element analysis of stress distribution in peri‐implant bone with relined dentures and different heights of healing caps. J. Oral Rehabil. 2011;38(9):691-6. Yamanishi Y, Yamaguchi S, Imazato S, Nakano T, Yatani H. Effects of the implant design on peri‐implant bone stress and abutment micromovement: three‐dimensional finite element analysis of original computer‐aided design models. J. Periodontol. 2014;85(9):e333-8. Lemos CA, Verri FR, Noritomi PY, Kemmoku DT, de Souza Batista VE, Cruz RS, de Luna Gomes JM, Pellizzer EP. Effect of bone quality and bone loss level around internal and external connection implants: A finite element analysis study. J. Prosthet. Dent. 2021;125(1):137-e1. Bramanti E, Cervino G, Lauritano F, Fiorillo L, D’Amico C, Sambataro S, Denaro D, Famà F, Ierardo G, Polimeni A, Cicciù M.FEM and von mises analysis on prosthetic crowns structural elements: Evaluation of different applied materials. Sci. World J. 2017; (1):1029574. . Reddy MS, Sundram R, Abdemagyd HA. Application of finite element model in implant dentistry: A systematic review. J Pharm Bioallied Sci 2019;11:85. Akça KI, Iplikçioğlu H. Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism. J. Oral Rehabil 2002;29(4):350-6. Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001;85:585-98. Pandey A, Durrani F, Rai SK, Singh NK, Singh P, Verma R, Kumar J. Comparison between all-on-four and all-on-six treatment concepts on stress distribution for full-mouth rehabilitation using three-dimensional finite element analysis: A biomechanical studyJ. Indian Soc. Periodontol. 2023 1;27(2):180-8. Shivakumar S, Kudagi VS, Talwade P. Applications of finite element analysis in dentistry: A review. Int. J. Oral Health Sci. 2021;13(5):415-22. Mohamed AM, Askar MG, El Homossany ME. Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: Non-linear finite element analysis study. BMC Oral Health. 2022; 22(1):196. Hassan NA, Elkhadem AH, Elkerdawy MW, Osman RB. Biomechanics of Different Types of PEEK as Implant Materials for Implant-Retained Mandibular Overdentures. Eur. j. prosthodont. restor. dent. 2022;30(2):113-20. Agnini A, Agnini AM, Romeo D, Chiesi M, Pariente L, Stappert CF. Clinical investigation on axial versus tilted implants for immediate fixed rehabilitation of edentulous arches: preliminary results of a single cohort study. Clin Implant Dent Relat Res. 2014;16(4):527-39. Himmlova L, Kácovský A, Konvic̆ková S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent. 2004;91(1):20-5. Winkler S, Morris HF, Ochi S. Implant survival to 36 months as related to length and diameter. Ann. Periodontol. 2000;5(1):22-31. Eazhil R, Swaminathan SV, Gunaseelan M, Kannan GV, Alagesan C. Impact of implant diameter and length on stress distribution in osseointegrated implants: A 3D FEA study. J Int Soc Prev Community Dent .2016;6(6):590-6. Maló P, de Araújo Nobre M, Moura Guedes C, Almeida R, Silva A, Sereno N, Legatheaux J. Short‐term report of an ongoing prospective cohort study evaluating the outcome of full‐arch implant‐supported fixed hybrid polyetheretherketone‐acrylic resin prostheses and the All‐on‐Four concept. Clin Implant Dent Relat Res .2018;20(5):692-702. Angelara K, Bratos M, Sorensen JA. Comparison of strength of milled and conventionally processed PMMA complete-arch implant-supported immediate interim fixed dental prostheses. J. Prosthet. Dent. 2023;129(1):221-7. Desai SR, Koulgikar KD, Alqhtani NR, Alqahtani AR, Alqahtani AS, Alenazi A, Heboyan A, Fernandes GV, Mustafa M. Three-dimensional FEA analysis of the stress distribution on titanium and graphene frameworks supported by 3 or 6-implant models. Biomimetics. 2023;8(1):15. Osman RB, Elkhadem AH, Ma S, Swain MV. Finite element analysis of a novel implant distribution to support maxillary overdentures. Int J Oral Maxillofac Implants. 2013;28(1). Altıparmak N, Polat S, Onat S. Finite element analysis of the biomechanical effects of titanium and Cfr-peek additively manufactured subperiosteal jaw implant (AMSJI) on maxilla. J Stomatol Oral Maxillofac Surg, Oral and Maxillofacial Surgery. 2023;124(1):101290. Rubo JH, Capello Souza EA. Finite‐element analysis of stress on dental implant prosthesis. Clin Implant Dent Relat Res. 2010;12(2):105-13. Fazi G, Tellini S, Vangi D, Branchi R. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis. Int J Oral Maxillofac Surg. 2011;26(4). Meriç G, Erkmen E, Kurt A, Tunç Y, Eser A. Influence of prosthesis type and material on the stress distribution in bone around implants: A 3-dimensional finite element analysis. J. Dent. Sci. 2011;6(1):25-32. Assunção WG, Gomes EA, Barao VA, Delben JA, Tabata LF, de Sousa EA. Effect of superstructure materials and misfit on stress distribution in a single implant-supported prosthesis: a finite element analysis. J Craniofac Surg. 2010;21(3):689-95. Dayan SC, Geckili O. The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis. Comput. Methods Biomech. Biomed. Engin. 2021;24(14):1606-17. Çiftçi Y, Canay Ş. Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials. Int J Prosthodont. 2001;14(5). Sertgöz A. Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis Int J Prosthodont. 1997;10(1). Aboelnagga MM. Comparative stress analysis of BioHPP and PEKK CAD/CAM frameworks in mandibular All-on-Four fixed-detachable prosthesis on its supporting implants. ASDJ. 2023;32(4):6-18. El-Rahman A, Aladdin N, El-Sharkawy AM, Mohy El-Din MH, Saad MS. Strain evaluation of peek cantilever bars around implants assisted mandibular overdentures (in vitro study). ADJALEXU. 2022;47(3):138-45. Ersöz MB, Mumcu E. Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study. J Adv Prosthodont .2022;14(6):346. Jaros OA, De Carvalho GA, Franco AB, Kreve S, Lopes PA, Dias SC. Biomechanical behavior of an implant system using polyether ether ketone bar: Finite element analysis. J Int Soc Prev Community Dent. 2018;8(5):446-50. Elkhooly AS, Elmasry SM, Mohamed ME, Zaky SZ. Effect of PEKK and Bio-HPP CAD-CAM Materials on Stress Distribution around Implants in Bar-Retained Implant-Supported Prostheses. Sapporo Med. J.2024;58(7). Yu W, Chen S, Ma L, Ma X, Xu X. Biomechanical Analysis of Different Framework Design, Framework Material and Bone Density in the Edentulous Mandible With Fixed Implant‐Supported Prostheses: A Three‐Dimensional Finite Element Study. J. Prosthodont. 2023;32(4):309-17. Jacques LB, Moura MS, Suedam V, Souza EA, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular‐cantilevered implant‐supported prostheses. Clin. Oral Implants Res. 2009;20(7):737-41. Lee KS, Shin SW, Lee SP, Kim JE, Kim JH, Lee JY, Lee KS, Shin SW, Lee SP, Kim JE, Kim JH. Comparative Evaluation of a Four-Implant-Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design. Int J Prosthodont. 2017;30(6). Tribst JP, Campanelli de Morais D, Melo de Matos JD, Lopes GD, Dal Piva AM, Souto Borges AL, Bottino MA, Lanzotti A, Martorelli M, Ausiello P. Influence of framework material and posterior implant angulation in full-arch all-on-4 implant-supported prosthesis stress concentration. Dent. J. 2022;10(1):12. Shetty R, Singh I, Sumayli HA, Jafer MA, Feroz SA, Bhandi S, Raj AT, Patil S, Ferrari M. Effect of prosthetic framework material, cantilever length and opposing arch on peri-implant strain in an all-on-four implant prostheses. Niger. J. Clin. Pract. 2021;24(6):866-73. Franco AG, de Carvalho GA, Dias SC, Ramos EV, Franco AB. Different protocol bar designs made of polyether ether ketone (PEEK) and metal: an analysis of mechanical behavior: Mechanical behavior of three PEEK infrastructures. IAJMH. 2022; 5:1-8. Göre E, Evlioğlu G. Assessment of the effect of two occlusal concepts for implant-supported fixed prostheses by finite element analysis in patients with bruxism. J Oral Implantol. 2014;40(1):68-75. Additional Declarations No competing interests reported. Cite Share Download PDF Status: Published Journal Publication published 09 May, 2025 Read the published version in Scientific Reports → Version 1 posted Editorial decision: Accepted 22 Apr, 2025 Reviews received at journal 15 Apr, 2025 Reviewers agreed at journal 14 Apr, 2025 Reviewers invited by journal 14 Apr, 2025 Submission checks completed at journal 11 Apr, 2025 First submitted to journal 28 Mar, 2025 You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-5183274","acceptedTermsAndConditions":true,"allowDirectSubmit":false,"archivedVersions":[],"articleType":"Article","associatedPublications":[],"authors":[{"id":442735180,"identity":"3b407ef7-aae8-443a-b103-f649f3c71c1f","order_by":0,"name":"Lamia Farouk Zaki Mohamed","email":"","orcid":"","institution":"faculty of Dentistry,Ain shams University","correspondingAuthor":false,"prefix":"","firstName":"Lamia","middleName":"Farouk Zaki","lastName":"Mohamed","suffix":""},{"id":442735181,"identity":"c284052f-53c1-40c8-bf28-0baafe80238e","order_by":1,"name":"Hebatallah Tarek Mohamed","email":"","orcid":"","institution":"faculty of Dentistry,Ain shams University","correspondingAuthor":false,"prefix":"","firstName":"Hebatallah","middleName":"Tarek","lastName":"Mohamed","suffix":""},{"id":442735182,"identity":"5a5d81c6-8d39-4953-86fa-8647130daeb5","order_by":2,"name":"Hany Ibrahim Eid","email":"","orcid":"","institution":"faculty of Dentistry,Ain shams University","correspondingAuthor":false,"prefix":"","firstName":"Hany","middleName":"Ibrahim","lastName":"Eid","suffix":""},{"id":442735183,"identity":"6f5c84d2-5fdf-4c41-b557-1ec387f49b68","order_by":3,"name":"Soha Saeid Mohammed","email":"data:image/png;base64,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","orcid":"","institution":"faculty of Dentistry,Ain shams University","correspondingAuthor":true,"prefix":"","firstName":"Soha","middleName":"Saeid","lastName":"Mohammed","suffix":""},{"id":442735184,"identity":"3863d985-2215-44f7-ac8e-b4b60619c99b","order_by":4,"name":"Rana Mohammad Abdelrahman","email":"","orcid":"","institution":"New Giza University","correspondingAuthor":false,"prefix":"","firstName":"Rana","middleName":"Mohammad","lastName":"Abdelrahman","suffix":""}],"badges":[],"createdAt":"2024-09-30 20:23:25","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-5183274/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-5183274/v1","draftVersion":[],"editorialEvents":[{"content":"https://doi.org/10.1038/s41598-025-99750-x","type":"published","date":"2025-05-09T15:56:56+00:00"}],"editorialNote":"","failedWorkflow":false,"files":[{"id":80628626,"identity":"32c7e49e-4011-4ac6-aef0-caa5c967b64b","added_by":"auto","created_at":"2025-04-15 11:22:11","extension":"png","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":4526432,"visible":true,"origin":"","legend":"\u003cp\u003eModel designing;(a): Bone cylinder, (b): Implant, (c): Multi-unit Abutment, (d): Temporary Titanium sleeve, (e): Implants splinted with titanium bar of 2mm thickness Titanium wire, (f): Implants splinted with PEEK bar of 3mm thickness, (g): Prosthetic superstructure designed using Exocad software to be in the form of full arch PMMA prosthesis.\u003cem\u003e\u003cstrong\u003e Image courtesy of Dr. Nermeen Ahmed Hassan, published under a CC BY open access license with permission.\u003c/strong\u003e\u003c/em\u003e\u003c/p\u003e","description":"","filename":"Figure1.png","url":"https://assets-eu.researchsquare.com/files/rs-5183274/v1/e5a2fbd1bde8dbf40017c57d.png"},{"id":80628275,"identity":"53174905-5642-4543-9fd8-2bddd1e90dd7","added_by":"auto","created_at":"2025-04-15 11:14:11","extension":"png","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":3802139,"visible":true,"origin":"","legend":"\u003cp\u003eModel meshing by subdividing the geometric model into small pieces called elements connected at common points called nodes.\u003cem\u003e\u003cstrong\u003e Image courtesy of Dr. Nermeen Ahmed Hassan, published under a CC BY open access license with permission\u003c/strong\u003e\u003c/em\u003e\u003c/p\u003e","description":"","filename":"Figure2.png","url":"https://assets-eu.researchsquare.com/files/rs-5183274/v1/2bebbee1aaa82099554b137d.png"},{"id":80629453,"identity":"5516bcc9-12f0-4dc3-a409-e9d989d0a7f1","added_by":"auto","created_at":"2025-04-15 11:30:11","extension":"png","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":3986941,"visible":true,"origin":"","legend":"\u003cp\u003eload application;(a): Application of bilateral vertical load of 200 on the central fossae premolar and the first molar (b): Application of Unilateral Oblique load to the lingual inclines of the buccal cusps of the premolar and first molar with an angle of about 45 degrees to the vertical axis of the tooth.\u003cem\u003e\u003cstrong\u003e Image courtesy of Dr. Nermeen Ahmed Hassan, published under a CC BY open access license with permission\u003c/strong\u003e\u003c/em\u003e\u003c/p\u003e","description":"","filename":"Figure3.png","url":"https://assets-eu.researchsquare.com/files/rs-5183274/v1/58876a0a1b559a9eed466f78.png"},{"id":80629451,"identity":"c482abae-e894-40fe-bcf1-0e1e7a726e62","added_by":"auto","created_at":"2025-04-15 11:30:11","extension":"png","order_by":4,"title":"Figure 4","display":"","copyAsset":false,"role":"figure","size":4016719,"visible":true,"origin":"","legend":"\u003cp\u003eStress distribution during the application of bilateral vertical load on (a): Marginal bone in Titanium model(TB), (b): Marginal bone in PEEK model(PB), (c): Titanium wire, (d): PEEK framework. \u003cem\u003e\u003cstrong\u003eImage courtesy of Dr. Nermeen Ahmed Hassan, published under a CC BY open access license with permission\u003c/strong\u003e\u003c/em\u003e\u003c/p\u003e","description":"","filename":"Figure4.png","url":"https://assets-eu.researchsquare.com/files/rs-5183274/v1/20cf008ee0b0f45f6b831a81.png"},{"id":80628630,"identity":"d154cefe-6650-4893-9263-1d403a6e1f67","added_by":"auto","created_at":"2025-04-15 11:22:11","extension":"png","order_by":5,"title":"Figure 5","display":"","copyAsset":false,"role":"figure","size":4021524,"visible":true,"origin":"","legend":"\u003cp\u003eStress distribution during the application of Unilateral Oblique load on (a): Marginal bone in Titanium model(TB), (b): Marginal bone in PEEK model (PB), (c): Titanium wire, (d): PEEK framework.\u003cem\u003e\u003cstrong\u003e Image courtesy of Dr. Nermeen Ahmed Hassan, published under a CC BY open access license with permission\u003c/strong\u003e\u003c/em\u003e\u003c/p\u003e","description":"","filename":"Figure5.png","url":"https://assets-eu.researchsquare.com/files/rs-5183274/v1/b689c5ace510c7bbc2f373a3.png"},{"id":80628270,"identity":"8625b209-09a9-44c5-bfc8-ac28f8c5399a","added_by":"auto","created_at":"2025-04-15 11:14:11","extension":"png","order_by":6,"title":"Figure 6","display":"","copyAsset":false,"role":"figure","size":5111628,"visible":true,"origin":"","legend":"\u003cp\u003eStrain distribution during the application of bilateral vertical load on (a): Marginal bone in Titanium model(TB), (b): Marginal bone in PEEK model (PB), Strain distribution during the application of Unilateral Oblique load on (c): Marginal bone in Titanium model(TB), (d): Marginal bone in PEEK model.\u003cem\u003e\u003cstrong\u003eImage courtesy of Dr. Nermeen Ahmed Hassan, published under a CC BY open access license with permission\u003c/strong\u003e\u003c/em\u003e\u003c/p\u003e","description":"","filename":"Figure6.png","url":"https://assets-eu.researchsquare.com/files/rs-5183274/v1/aa54ecff934b7243092ea643.png"},{"id":82537417,"identity":"828fbfc2-bef1-4c97-9ffc-912ce107539b","added_by":"auto","created_at":"2025-05-12 16:04:59","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":24151898,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-5183274/v1/886f4967-a75a-49b4-948d-5b1fde53a4b8.pdf"}],"financialInterests":"No competing interests reported.","formattedTitle":"\u003cp\u003eFinite Element Analysis of Welded Titanium Bar and Poly Ether Ether Ketone Bar in Maxillary Full Arch Splinted Interim Prosthesis\u003c/p\u003e","fulltext":[{"header":"Background","content":"\u003cp\u003eRehabilitation of edentulous patients with an implant-supported prosthesis typically involves the placement of implants and then, loading the prosthesis after 3\u0026ndash;4 months in the mandible and 6\u0026ndash;8 months in the maxilla [\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e]. Such a stress-free healing period permits the osseointegration of the implant, lowering the risk of implant failure and loss [\u003cspan citationid=\"CR2\" class=\"CitationRef\"\u003e2\u003c/span\u003e]. Two-stage protocol showed significant psychological and functional difficulties for patients who have recently extracted their remaining teeth never worn a removable prosthesis, since they must wear an interim removable prosthesis. Accordingly, the original two-stage protocol has been altered where implants were placed after immediate tooth extraction along with the immediate placement of a fixed interim prosthesis [\u003cspan citationid=\"CR3\" class=\"CitationRef\"\u003e3\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eInterim prostheses have several advantages, including serving as a diagnostic tool, helping evaluation of peri-implant soft tissue, evaluation of neighboring teeth, and evaluation of the patient\u0026rsquo;s oral hygiene. They also are helpful for patient management (esthetic, phonetic, psychological), communication between patient, prosthodontist, and technician, determination for implant site development, healing of the soft tissue around the implants, potentially loading the implants, improving tissue contours related to emergence profile, and developing of an interdental or papillae, and therefore potential avoidance of a third surgical procedure [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e, \u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eAccording to Lin et al., the most common complications associated with an interim full-arch fixed acrylic resin prosthesis are the fracture of the prosthetic structure and fracture of the veneering material [\u003cspan citationid=\"CR6\" class=\"CitationRef\"\u003e6\u003c/span\u003e]. Such fracture during the healing period eliminates cross- arch stabilization and disrupts stress distribution patterns [\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eSeveral reasons have made the full arch fixed Interim prostheses susceptible to fracture during function, acrylic porosities and/or foreign materials embedded in the acrylic as \u0026ldquo;Air pockets\u0026rdquo; have been observed in the cracked acrylic bases of many restorations [\u003cspan citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e]. It was reported that flexural fatigue, which occurred after repeated flexing of the PMMA prosthesis, could also lead to fractures [\u003cspan citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eSplinting (rigid or non-rigid) has been shown to prevent axial rotation and movement of immediately loaded implants. However, the effectiveness of splinting to promote implant osseointegration was found to be uncertain since previous studies have shown osseointegration of un-splinted immediately loaded implants [\u003cspan citationid=\"CR10\" class=\"CitationRef\"\u003e10\u003c/span\u003e]. According to some studies, splinting of implants reduces the risk of overload to each implant because of the increased surface area and enhanced biomechanical distribution [\u003cspan citationid=\"CR11\" class=\"CitationRef\"\u003e11\u003c/span\u003e, \u003cspan citationid=\"CR12\" class=\"CitationRef\"\u003e12\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eSplinting could be either rigid by a metal bar or semi-rigid with acrylic resin. The semi-rigid splinting can be fabricated by CAD/CAM technology at the correct vertical dimension of occlusion before an immediate load, or the patient's pre-existing denture can be used after adjusting it to serve as a fixed interim prosthesis [\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e]. Semi-rigid splinting doesn\u0026rsquo;t provide adequate stress reduction on the bone surrounding the implants. On the other hand, it offers better passivity to the implant- supported fixed prosthesis because of the lack of a metal support. Accordingly, semi-rigid splinting has been recommended for the healing period after implant placement (4\u0026ndash;6 months), which is important for implant survival [\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eSeveral studies reported successful oral rehabilitation of edentulous maxilla and mandible with a fixed definitive restoration supported by an intra-orally welded titanium wire on the same day of implant placement surgery [\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e]. The intra-oral welding technique allows rigid splinting of multiple implants for immediate loading on the same day, thus ensuring a predictable fixation of implants in the healing period with a considerable reduction in the micro-movements [\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIntraoral welding was reported to be a technique sensitive procedure. It is crucial to have total contact between the welding abutment and the titanium bar during the welding procedure, a perfect joint mandate the application of firm and constant pressure [\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e]. Furthermore, there are more limits to syncrystallization and electric resistance welding, since they are not efficient on every kind of metal and alloy, and these cannot be utilized on patients with pacemakers [\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e].\u003c/p\u003e \u003cp\u003ePolyetheretherketone (PEEK) is a high-performance polymer belonging to the polyaryletherketone group, it has excellent physical and chemical properties as low specific weight (1.3 g/cm3) and low flexural strength (165\u0026ndash;170 MPa), proper elasticity (3,600 MPa), and suitable hardness (20 HV) [\u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e, \u003cspan citationid=\"CR19\" class=\"CitationRef\"\u003e19\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eThe main beneficial feature of this material is the reduced modulus of elasticity than that of the metallic materials and is relatively comparable to that of the human bone, hence minimizing the stress on the surrounding bone [\u003cspan citationid=\"CR20\" class=\"CitationRef\"\u003e20\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIn their finite element study to examine the behavior of polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) prosthetic frameworks, Villefort RF et al [\u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e] reported that the superior shock absorbance of PEKK has led to a reduced stress concentration on the prosthetic screw and prosthetic base. This showed clinically a decreased risk of fracture on the acrylic base and screw loosening.\u003c/p\u003e \u003cp\u003eIt was reported that the clinical service life of implant prosthesis is influenced by the load transfer between the implant and alveolar bone [\u003cspan citationid=\"CR22\" class=\"CitationRef\"\u003e22\u003c/span\u003e]. Moreover, studies on traditional implants have demonstrated that stress concentration is prevalent in the marginal cortical bone corresponding to the neck of the implant [\u003cspan citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e]. This stress overload maximizes the risk of marginal bone resorption around the implant [\u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e]. Since marginal bone quality is a critical parameter controlling the osteo-mechanical behavior in implant biomechanics [\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eFinite element model is a computer technique for stress distribution analysis that has been used for making virtual models. The influence of loading strengths over peri-implant and dental implant elements can be recorded by applying the equivalent stress (von Mises stress) expressed in Megapascals (MPa) [\u003cspan citationid=\"CR26\" class=\"CitationRef\"\u003e26\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eThe finite element analysis (FEA) study has significant clinical implications, as it offers a helpful understanding of the biomechanical behavior of the splinting materials. Additionally, it would help in predicting the reaction of these materials under various loading conditions. [\u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e] Consequently, improving the long-term clinical stability of the implant system and the overall performance.\u003c/p\u003e \u003cp\u003eMoreover, FEA has been shown to be an applicable method for analyzing the distribution of stress and clinical behavior of geometrically complex prosthetic systems that include dental implant, bone, and prosthesis [\u003cspan citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e], accordingly, clinicians will be able to identify areas of high stresses that may cause bone loss or future implant failure and therefore, they can follow better planning and maintenance protocols. [\u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e]\u003c/p\u003e \u003cp\u003eThis can definitely improve the clinical decision-making, the treatment outcomes, hence reduce the risk of complications. So, the applications of theses FEA studies can guarantee a safe and effective real clinical applications\u003c/p\u003e \u003cp\u003eEven with all these benefits, FEA studies comprise a number of limitations. The loads tend to be more simplified than the actual complex forces encountered during mastication and various other functions. [\u003cspan citationid=\"CR29\" class=\"CitationRef\"\u003e29\u003c/span\u003e], in addition, they can\u0026rsquo;t fully capture the nature of the anatomical structures as the bone or the soft tissues. Bone is an incredibly complicated living structure and its characteristics vary from individual to individual. In addition, the use of FEM when studying the extremely accurate anatomy of a bone structure may limit the analysis to that particular structure. [\u003cspan citationid=\"CR30\" class=\"CitationRef\"\u003e30\u003c/span\u003e]\u003c/p\u003e \u003cp\u003eMoreover, FEA is not time-dependent. Biological dynamics of a living component cannot be modeled with precision as it is difficult to take factors like time and other factors the structure is subjected to in accounts. And to obtain a high quality FEA, a specialized software is needed which may not be available to all researches. [\u003cspan citationid=\"CR31\" class=\"CitationRef\"\u003e31\u003c/span\u003e]\u003c/p\u003e \u003cp\u003eThus, the purpose of this study was to evaluate the mechanical behavior of maxillary full arch loaded interim prostheses fabricated using different splinting materials. The null hypothesis was that the use of different splinting materials would not affect the prosthesis\u0026rsquo; mechanical behavior.\u003c/p\u003e"},{"header":"Methods","content":"\u003cp\u003eThe current study included two steps: virtual model construction and three-dimensional Finite Element Analysis. Two virtual models were made in this study. Both with six implants are used. In model TB, the implants were splinted with welded titanium bar; however, in model PB, the implants were splinted with PEEK bar.\u003c/p\u003e \u003cdiv id=\"Sec3\" class=\"Section2\"\u003e \u003ch2\u003eModel construction\u003c/h2\u003e \u003cp\u003eFor virtual model construction, an educational maxillary edentulous cast (Ramses medical products, Cairo, Egypt) was used. It was scanned using 3D scanner (CeraMap 400 Amann Girrbach America Inc., Koblach, Austria) and modelled using Exocad software (Exocad DentalDB 3.1 Rijeka CAD/CAM software) (Exocad America, Inc. Darmstadt, Germany). As (D3) bone density is often observed in the maxilla, the cast was virtually formed to represent a 1 mm outer cortical bone covering the trabecular bone (Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e1\u003c/span\u003e.a). Reverse Engineering was made to the cast and exported in Standard Tessellation Language (STL) file. This STL virtual cast was imported into the Mesh Mixer software (Version 3.5.0) (Mesh Mixer, Autodesk, San Rafael, California, United States of America) for further smoothening, gap filling and exported as STL format [\u003cspan citationid=\"CR32\" class=\"CitationRef\"\u003e32\u003c/span\u003e].\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eFor the bone cylinder, a new plane was created parallel to the top plane, and a split was made in the top part of the cylinder along the new plane to facilitate collecting the results from the marginal peri-implant bone. Therefore, the marginal peri-implant bone is 2 mm height and 1.3 mm thickness [\u003cspan citationid=\"CR33\" class=\"CitationRef\"\u003e33\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eSix dental implants were planned to be placed in the right lateral incisor R2, right first premolar R4, right first molar R6, left central incisor L1, left canine L3, left first molar L6. All implants were placed axially [\u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eThe implants were modelled using the Solidworks software (2023 SP0 software) (Solidworks 2023 x64 Edition premium package) with 4.2 mm diameter and a 10 mm length [\u003cspan additionalcitationids=\"CR36\" citationid=\"CR35\" class=\"CitationRef\"\u003e35\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR37\" class=\"CitationRef\"\u003e37\u003c/span\u003e] (Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e1\u003c/span\u003e.b). Straight Multiunit abutments and titanium bases were also modelled using the Solidworks software (Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e1\u003c/span\u003e, c and d).\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eIn model TB, the implants were splinted with titanium bar of 2mm thickness [\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e] (Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e1\u003c/span\u003e.e) while in model PB, the implants were splinted with PEEK bar of 3mm thickness [\u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e, \u003cspan citationid=\"CR38\" class=\"CitationRef\"\u003e38\u003c/span\u003e] (Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e1\u003c/span\u003e.f). All other components of both models were identical to standardize all the variables.\u003c/p\u003e \u003cp\u003eThe prosthetic superstructure was designed using Exocad software (Exocad DentalDB 3.1 Rijeka CAD/CAM software) (Exocad America, Inc. Darmstadt, Germany) to be in the form of full arch PMMA prosthesis [\u003cspan citationid=\"CR39\" class=\"CitationRef\"\u003e39\u003c/span\u003e] (Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e1\u003c/span\u003e.g). The STL files of the dental implants, abutments and prosthetic superstructure were assembled by Solidworks software.\u003c/p\u003e \u003cp\u003eStraight multiunit abutment with 5 mm diameter was exported as STL file from BlueSky Plan version 4.12.13 (64 bit) (Bio software, LLC). The STL file was then exported to Solidworks and was reversed engineered to form a 3D cast model [\u003cspan citationid=\"CR32\" class=\"CitationRef\"\u003e32\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eFor the titanium sleeves, a 2D sketch of circle with 5 mm diameter was drawn in the top plane of the cap part. This circle was extruded using boss extrude tool to form a cylinder of 8 mm length. Finally, a cavity was made inside the cap part and the cylindrical part to form the final 3D hollow Titanium sleeve [\u003cspan citationid=\"CR32\" class=\"CitationRef\"\u003e32\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eThe two models were exported to ANSYS software (Ansys 2022 R1) (Ansys, Inc, Pennsylvania, USA) to start the analysis process, the cervical part of each bone cylinder was assumed to be compact bone and the remaining part of the bone cylinder was assumed to be cancellous bone. The implant, multi-unit abutment, temporary titanium sleeves and the metal wire are all assumed to be made from titanium alloy. The PEEK framework was assigned to be made from BioHPP PEEK. While all the conversion prosthesis was assumed to be made from PMMA. The materials were assumed to have linear isotropic behavior and the modulus of elasticity and Poisson's ratio for the different component materials used in the study are listed in the table below, Table\u0026nbsp;\u003cspan refid=\"Tab1\" class=\"InternalRef\"\u003e1\u003c/span\u003e. All components were constructed in a way that assures 100% contact along the interfaces.\u003c/p\u003e \u003cp\u003eTable\u0026nbsp;\u003cspan refid=\"Tab1\" class=\"InternalRef\"\u003e1\u003c/span\u003e legend: properties of each component in the model\u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab1\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 1\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003ecomponent properties\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"3\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e \u003cp\u003eMaterial\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003eModulus of elasticity\u003c/p\u003e \u003cp\u003e(MPa)\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003ePoisson\u0026rsquo;s ratio\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eCompact bone\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c2\"\u003e \u003cp\u003e15,000\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e \u003cp\u003e0.3\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eCancellous bone\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c2\"\u003e \u003cp\u003e1,500\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e \u003cp\u003e0.3\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003ePMMA\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c2\"\u003e \u003cp\u003e2,770\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e \u003cp\u003e0.35\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eTitanium Alloy\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c2\"\u003e \u003cp\u003e110,000\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e \u003cp\u003e0.3\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003ePEEK\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c2\"\u003e \u003cp\u003e4,200\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e \u003cp\u003e0.38\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \u003cp\u003eMeshing the models were done by subdividing the geometric model into small pieces called elements connected at common points called nodes. (Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e2\u003c/span\u003e).\u003c/p\u003e \u003cp\u003eThe total number of elements in the model TB was 139733 and in the model PB was 147951. However, the number of nodes in the model TB was 139733 and in the model PB was 268653.The fixed restraints were applied to the inferior aspect and to all the lateral aspects of the maxillary virtual cast to avoid any bodily displacement during loading.\u003c/p\u003e \u003c/div\u003e\n\u003ch3\u003eLoad application\u003c/h3\u003e\n\u003cp\u003eTwo loading scenarios were applied [\u003cspan class=\"CitationRef\"\u003e33\u003c/span\u003e, \u003cspan class=\"CitationRef\"\u003e40\u003c/span\u003e, \u003cspan class=\"CitationRef\"\u003e41\u003c/span\u003e]. The first scenario simulated a Vertical Load of 200 N that was applied bilaterally in the posterior region where the first molar tooth received load of 100 N and each premolar received 50 N load (Fig. \u003cspan class=\"InternalRef\"\u003e3\u003c/span\u003e.a).\u003c/p\u003e\n\u003cp\u003eThe vertical load was applied on the central fossae of the premolar and the first molar. The second scenario simulated an Oblique (Lateral) Load of 200 N was applied unilaterally in the posterior region of the right side where The first molar tooth received load of 100 N and each premolar received 50 N load (Fig. \u003cspan class=\"InternalRef\"\u003e3\u003c/span\u003e.b). Lateral load was applied to the lingual inclines of the buccal cusps of the premolar and first molar with an angle of about 45 degrees to the vertical axis of the tooth.\u003c/p\u003e\n\u003cp\u003eIn both models, the stresses displayed are the maximum principle stress for the (1) cervical part of the bone cylinder (marginal bone) (Fig. \u003cspan class=\"InternalRef\"\u003e4\u003c/span\u003e.a and b, Fig. \u003cspan class=\"InternalRef\"\u003e5\u003c/span\u003e.a and b). and (2) titanium wire (Fig. \u003cspan class=\"InternalRef\"\u003e4\u003c/span\u003e.c and Fig. \u003cspan class=\"InternalRef\"\u003e5\u003c/span\u003e.c). and PEEK framework (Fig. \u003cspan class=\"InternalRef\"\u003e4\u003c/span\u003e.d and Fig. \u003cspan class=\"InternalRef\"\u003e5\u003c/span\u003e.d)\u003c/p\u003e\n\u003cp\u003eIn both models, the strain displayed for the (1) cervical part of the bone cylinder (marginal bone) under vertical load (Fig. \u003cspan class=\"InternalRef\"\u003e6\u003c/span\u003e.a and b). and (2) cervical part of the bone cylinder (marginal bone) under oblique load (Fig. \u003cspan class=\"InternalRef\"\u003e6\u003c/span\u003e.c and Fig. \u003cspan class=\"InternalRef\"\u003e6\u003c/span\u003e.d).\u003c/p\u003e\n\u003cp\u003eThey were displayed as graphical output in the form of color coded maps and numeric output that displayed the amount of the maximum equivalent stresses (Von-Mises stresses) in Megapascal (Mpa) [39, 40]. Then, the results were collected from both models and tabulated.\u003c/p\u003e"},{"header":"Results","content":"\u003cp\u003eThe results of this study showed that under bilateral vertical load, the marginal bone stresses at the left and right molars were 15.07 \u0026amp;14.485 MPa receptively for Model TB (titanium framework), and 14.977\u0026amp; 14.927 MPa receptively for Model PB (PEEK framework). The results recorded were comparable in both models.\u003c/p\u003e\u003cp\u003eMoreover, it was found that under bilateral vertical load, PEEK framework had better distribution and lower stresses than titanium framework. The stresses were 8.3313 and 54.924 MPa in PEEK and titanium frameworks respectively Table\u0026nbsp;\u003cspan refid=\"Tab2\" class=\"InternalRef\"\u003e2\u003c/span\u003e. This may be contributed to the connection between PEEK bar and abutments. Regarding the stresses on the implants, it was found that the results in Model TB are slightly higher than that in Model PB, and this may be contributed to the shock absorbing nature of PEEK that tends to dissipate stresses under the bilateral vertical load which accordingly transmits less stresses to the implants.\u003c/p\u003e\u003cdiv class=\"gridtable\"\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c5\" colnum=\"5\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c6\" colnum=\"6\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c7\" colnum=\"7\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c8\" colnum=\"8\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c9\" colnum=\"9\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c10\" colnum=\"10\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c11\" colnum=\"11\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c12\" colnum=\"12\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c13\" colnum=\"13\"\u003e\u003c/div\u003e\u003ctable float=\"Yes\" id=\"Tab2\" border=\"1\"\u003e\u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 2\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eEquivalent (von-Mises) Stresses in case of Bilateral Vertical Load\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e\u003ccolgroup cols=\"13\"\u003e\u003c/colgroup\u003e\u003cthead\u003e\u003ctr\u003e\u003cth align=\"left\" colspan=\"13\" nameend=\"c13\" namest=\"c1\"\u003e \u003cp\u003eBilateral Vertical Loading\u003c/p\u003e \u003c/th\u003e\u003c/tr\u003e\u003c/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\" morerows=\"2\" rowspan=\"3\"\u003e \u003cp\u003eMarginal bone\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colspan=\"6\" nameend=\"c7\" namest=\"c2\"\u003e \u003cp\u003ePEEK\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colspan=\"6\" nameend=\"c13\" namest=\"c8\"\u003e \u003cp\u003etitanium\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eleft first molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003eleft canine\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003eleft central\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003eright lateral\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003eright first pre-molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003eright first molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003eleft first molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003eleft canine\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003eleft central\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003eright lateral\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003eright first pre-molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c13\"\u003e \u003cp\u003eright first molar\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e14.9 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e17.5 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e4.5 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e4.1 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e13.3 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e14.9 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e15.1 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e18.5 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e5.6 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e4.7 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e13.3 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c13\"\u003e \u003cp\u003e14.4 MPa\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eDental implants\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e55 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e25 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e10.8 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e17.9 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e43 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e71.4 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e58.7 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e25.8 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e14.4 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e18.5 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e45.9 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c13\"\u003e \u003cp\u003e73.2 MPa\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eframework\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colspan=\"6\" nameend=\"c7\" namest=\"c2\"\u003e \u003cp\u003e8.3 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colspan=\"6\" nameend=\"c13\" namest=\"c8\"\u003e \u003cp\u003e54.9 MPa\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003c/div\u003e\u003cp\u003ePEEK, polyetheretherketone. MPa: Mega Pascal unit.\u003c/p\u003e\u003cp\u003eTable\u0026nbsp;\u003cspan refid=\"Tab2\" class=\"InternalRef\"\u003e2\u003c/span\u003e legend: Comparison of the maximum recorded stress values in the marginal bone and the framework between the models PB and TB during the bilateral vertical loading scenario.\u003c/p\u003e\u003cp\u003eUnder unilateral oblique forces, the marginal bone stresses at the left and right molars were 3.9284 \u0026amp;173.94 MPa receptively for Model TB. Whereas for Model PB, they were found to be 4.1725\u0026amp;166.84 MPa respectively. PEEK is showing better mechanical response compared to titanium framework. While PEEK framework showed higher stresses than the titanium framework. The stresses were 168.18 \u0026amp;106.03 MPa respectively. And again, this may be contributed to the nature of the connection between PEEK bar and abutments Table\u0026nbsp;\u003cspan refid=\"Tab4\" class=\"InternalRef\"\u003e3\u003c/span\u003e. In regards to the stresses on the implants, it was found again that the results in Model TB are higher than that in Model PB, and this may be caused by the nature of PEEK under the oblique load that tends to accumulate the stresses within the PEEK itself transmitting less stresses to the implants.\u003c/p\u003e\u003cdiv class=\"gridtable\"\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c5\" colnum=\"5\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c6\" colnum=\"6\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c7\" colnum=\"7\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c8\" colnum=\"8\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c9\" colnum=\"9\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c10\" colnum=\"10\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c11\" colnum=\"11\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c12\" colnum=\"12\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c13\" colnum=\"13\"\u003e\u003c/div\u003e\u003ctable float=\"Yes\" id=\"Tab3\" border=\"1\"\u003e\u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 3\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eEquivalent (von-Mises) Stresses in case of Unilateral Oblique Load\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e\u003ccolgroup cols=\"13\"\u003e\u003c/colgroup\u003e\u003cthead\u003e\u003ctr\u003e\u003cth align=\"left\" colspan=\"13\" nameend=\"c13\" namest=\"c1\"\u003e \u003cp\u003eUnilateral oblique load\u003c/p\u003e \u003c/th\u003e\u003c/tr\u003e\u003c/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\" morerows=\"2\" rowspan=\"3\"\u003e \u003cp\u003eMarginal bone\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colspan=\"6\" nameend=\"c7\" namest=\"c2\"\u003e \u003cp\u003ePEEK\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colspan=\"6\" nameend=\"c13\" namest=\"c8\"\u003e \u003cp\u003etitanium\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eLeft first molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003eLeft canine\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003eLeft central\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003eRight lateral\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003eRight first pre-molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003eRight first molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003eLeft first molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003eLeft canine\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003eLeft central\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003eRight lateral\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003eRight first pre-molar\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c13\"\u003e \u003cp\u003eRight first molar\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e4.1 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e11.1 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e37.1 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e46.7 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e126.4 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e166.8 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e3.9 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e16.6 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e43.5 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e51 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e128.9 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c13\"\u003e \u003cp\u003e173.9 MPa\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eDental implants\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e9.7 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e30 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e100.2 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e184.4 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e484.4 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e699.4 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e10.2 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e38 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e113.5 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e186.6 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e508 MPa\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colname=\"c13\"\u003e \u003cp\u003e715 MPa\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eframework\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colspan=\"6\" nameend=\"c7\" namest=\"c2\"\u003e \u003cp\u003e168.1\u003c/p\u003e \u003c/td\u003e\u003ctd align=\"left\" colspan=\"6\" nameend=\"c13\" namest=\"c8\"\u003e \u003cp\u003e106\u003c/p\u003e \u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003c/div\u003e\u003cp\u003ePEEK, polyetheretherketone. MPa: Mega Pascal unit.\u003c/p\u003e\u003cdiv\u003e\n \u003cp\u003eTable 3 legend: Comparison of the maximum recorded stress values in the marginal bone and the framework between the models PB and TB during the unilateral oblique loading scenario\u003c/p\u003e\n \u003cp\u003eRegarding the strain, it was found that that under bilateral vertical load, the marginal bone strain at the left and right molars were 8.90 \u0026amp;9.66 mm/mm MPa receptively for Model TB (titanium framework), 9.98 \u0026amp;9.95 \u0026nbsp; mm/mm receptively for Model PB (PEEK framework). The results recorded were comparable in both models.\u003c/p\u003e\n \u003ctable id=\"Tab4\" border=\"1\"\u003e\n \u003ccaption language=\"En\"\u003e\n \u003cdiv\u003e\n \u003cp\u003eTable 4: Equivalent Elastic Strain (mm/mm) in case of Bilateral Vertical Load\u003c/p\u003e\n \u003c/div\u003e\n \u003c/caption\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth align=\"left\" colspan=\"13\"\u003e\n \u003cp\u003eBilateral Vertical Loading\u003c/p\u003e\n \u003c/th\u003e\n \u003c/tr\u003e\n \u003c/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd align=\"left\" rowspan=\"3\"\u003e\n \u003cp\u003eMarginal bone\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\" colspan=\"6\"\u003e\n \u003cp\u003ePEEK\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\" colspan=\"6\"\u003e\n \u003cp\u003etitanium\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft first molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft canine\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft central\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight lateral\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight first pre-molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight first molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft first molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft canine\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft central\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight lateral\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight first pre-molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight first molar\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e9.98 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e1.17 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e3.06 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e2.71 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e8.9 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e9.95 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e8.90 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e1.24 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e3.74 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e3.18 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e8.88 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e9.66 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003c/tbody\u003e\n \u003c/table\u003e\n\u003c/div\u003e\n\u003cp\u003ePEEK, polyetheretherketone.\u003c/p\u003e\n\u003cp\u003eTable\u0026nbsp;4 legend: Comparison of the maximum recorded strain values in the marginal bone between the models PB and TB during the bilateral vertical loading scenario.\u003c/p\u003e\n\u003cp\u003eWhile under unilateral oblique forces, the marginal bone strain at the left and right molars were 2.621 \u0026amp;1.166 mm/mm receptively for Model TB. Whereas for Model PB, they were found to be 2.78 \u0026amp;1,11 mm/mm respectively. The results recorded were comparable in both models.\u003c/p\u003e\n\u003cdiv\u003e\n \u003ctable id=\"Tab5\" border=\"1\"\u003e\n \u003ccaption language=\"En\"\u003e\n \u003cdiv\u003eTable 5\u003c/div\u003e\n \u003cdiv\u003e\n \u003cp\u003eEquivalent Elastic Strain(mm/mm) in case of Unilateral Oblique Load\u003c/p\u003e\n \u003c/div\u003e\n \u003c/caption\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth align=\"left\" colspan=\"13\"\u003e\n \u003cp\u003eUnilateral oblique load\u003c/p\u003e\n \u003c/th\u003e\n \u003c/tr\u003e\n \u003c/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd align=\"left\" rowspan=\"3\"\u003e\n \u003cp\u003eMarginal bone\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\" colspan=\"6\"\u003e\n \u003cp\u003ePEEK\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\" colspan=\"6\"\u003e\n \u003cp\u003etitanium\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft first molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft canine\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft central\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight lateral\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight first pre-molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight first molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft first molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft canine\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eLeft central\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight lateral\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight first pre-molar\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003eRight first molar\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e2.78 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e1.38 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e2.48 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e3.12 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e8.43 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e1.11 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e2.62 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e1.11 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e2.90 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e3.40\u003c/p\u003e\n \u003cp\u003emm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e8.60 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd align=\"left\"\u003e\n \u003cp\u003e1.16 mm/mm\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003c/tbody\u003e\n \u003c/table\u003e\n\u003c/div\u003e\n\u003cp\u003ePEEK, polyetheretherketone.\u003c/p\u003e\n\u003cp\u003eTable 5 legend: Comparison of the maximum recorded strain values in the marginal bone between the models PB and TB during the unilateral oblique loading scenario\u003c/p\u003e"},{"header":"DISCUSSION","content":"\u003cp\u003eThe present study evaluated the stress distribution along the marginal bone using two different splinting materials under vertical and oblique loads. The results showed that both splinting materials have different mechanical responses, thus, the null hypothesis was rejected.\u003c/p\u003e \u003cp\u003eThe clinical evaluation of the stress and strain distribution in peri-implant bone areas is difficult and not feasible in most situations. Thus, FEA is an appropriate method for evaluating the distribution of stresses and clinical performance of geometrically complex prosthetic systems that include dental implant, bone, and prosthesis [\u003cspan citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eAs the study that ran by Altıparmak et al., where three - dimensional finite element analysis was used to examine the stresses that occur under occlusal forces on the bone, and the implant systems made of Titanium and Polyether ether ketone (PEEK) material [\u003cspan citationid=\"CR42\" class=\"CitationRef\"\u003e42\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eSince FEA is a simulation, increasing the mesh density in the regions to be evaluated on the model improved the data accuracy. Like previous finite element analysis studies related to implantology research, our study assumed that all modeled structures are in constant contact with each other [\u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eRegarding the influence of the number of implants on the structure, it is proved that the placement of six implants distribute stresses more evenly. In a study conducted by Fazi et al. [\u003cspan citationid=\"CR44\" class=\"CitationRef\"\u003e44\u003c/span\u003e] the stress distribution in 3-4-5 implant-supported prosthesis was investigated and it was found that load accumulation on the system declined with 5 implant-supported prosthesis.\u003c/p\u003e \u003cp\u003eIn a recent study by Desai et al. [\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e], two loading forces were applied, bilateral vertical forces which represented a clenching situation, and the unilateral which simulated the masticatory forces.\u003c/p\u003e \u003cp\u003eIn order to simulate the mean posterior bite force values, a vertical load of 200 N (50 N for each premolar and 100 N for the first molar) was applied on the central fossae of the premolars and the first molar. On the other hand, the oblique load was applied to the lingual inclines of the buccal cusps of the premolars and the first molar with an angle of about 45 degrees to the vertical axis. This is consistent with the studies done by Osman et al, and Hassan et al. [\u003cspan citationid=\"CR33\" class=\"CitationRef\"\u003e33\u003c/span\u003e, \u003cspan citationid=\"CR41\" class=\"CitationRef\"\u003e41\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eAlso, Meric et al. [\u003cspan citationid=\"CR45\" class=\"CitationRef\"\u003e45\u003c/span\u003e], showed that materials used in the fabrication of dental prostheses can influence the loading of dental implants and may potentially lead to bone deformation.\u003c/p\u003e \u003cp\u003eAssun\u0026ccedil;\u0026atilde;o et al. [\u003cspan citationid=\"CR46\" class=\"CitationRef\"\u003e46\u003c/span\u003e], concluded that the use of rigid framework materials in implant supported prostheses increased the amount of stress on dental implants. Unlike the study conducted by Dayan et al. [\u003cspan citationid=\"CR47\" class=\"CitationRef\"\u003e47\u003c/span\u003e], which concluded that the fabrication of frameworks from rigid materials in All-on-4 prostheses reduces stress in dental implants and peri-implant bone when the distal implants are tilted 30\u0026deg;.\u003c/p\u003e \u003cp\u003eOther studies, as the one performed by \u0026Ccedil;ift\u0026ccedil;i and Canay [\u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e48\u003c/span\u003e], and the study ran by Sertg\u0026ouml;z [\u003cspan citationid=\"CR49\" class=\"CitationRef\"\u003e49\u003c/span\u003e], where they reported that the use of less rigid restorative materials resulted in high stress in dental implants and supporting tissues.\u003c/p\u003e \u003cp\u003eGarg J [\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e], demonstrated that rigid framework splinting obtained by intraoral welding, can control the micro-movements in immediate loading protocols and decrease the mechanical stresses exerted on each single implant, accordingly, assuring an optimal distribution of occlusal load and reducing the lateral forces on healing implant.\u003c/p\u003e \u003cp\u003eAlthough, some studies as the one performed by Aboelnagga M, where it was concluded that using polyether-ketone-ketone (PEKK) for constructing the framework of prosthesis led to favorable stress distribution and reduction of stresses induced to supporting implants [\u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eAlso, El-Rahman A et al. [\u003cspan citationid=\"CR51\" class=\"CitationRef\"\u003e51\u003c/span\u003e], studied the behavior of PEEK bar under cyclic loading, where it exerted less strain and showed favorable load distribution around the implants and on the ridge areas.\u003c/p\u003e \u003cp\u003eThe data of this study showed that the intensity and distribution of the equivalent stresses, in unilateral oblique loads, in the PEEK framework were higher than the Ti frameworks. While under bilateral vertical load the intensity and distribution of the equivalent stresses were higher in Ti frameworks. This might give a speculation of an improved load distribution along the PEEK framework in model PB compared to model TB. Such a speculation might be related to the shock absorption and low elastic modulus of PEEK.\u003c/p\u003e \u003cp\u003eThe findings of this study coincide with the study done by Ers\u0026ouml;z and Mumcu [\u003cspan citationid=\"CR52\" class=\"CitationRef\"\u003e52\u003c/span\u003e], and Jaros et al. [\u003cspan citationid=\"CR53\" class=\"CitationRef\"\u003e53\u003c/span\u003e], which showed that PEEK responded differently under oblique and axial load; as under oblique loading PEEK accumulated stresses instead of distributing it, in contrast to the stiffer CoCr, ZrO2 and Ti. This is based on the material\u0026rsquo;s ability for shock absorption and the low elastic modulus.\u003c/p\u003e \u003cp\u003eAlso, the study done by Elkhooly AS et al., examined the pattern of stress distribution along PEKK and Bio-HPP CAD-CAM bar materials in implant-supported prostheses. They found that under unilateral loads, the strains concentrated at the loaded implants and ridge leading to statistically significantly larger mean micro-strains on the loaded side compared to the unloaded side [\u003cspan citationid=\"CR54\" class=\"CitationRef\"\u003e54\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIn accordance to our study, Yu et al. [\u003cspan citationid=\"CR55\" class=\"CitationRef\"\u003e55\u003c/span\u003e] reported that compared to polymeric frameworks, zirconia and metals caused lower stresses on bone and implant, and greater stresses on framework.\u003c/p\u003e \u003cp\u003eIt was reported that the biomechanical qualities of high elastic modulus materials made them more appropriate for implant-supported prostheses frameworks [\u003cspan citationid=\"CR56\" class=\"CitationRef\"\u003e56\u003c/span\u003e]. A three-dimensional finite element analysis study done by Shin et al. [\u003cspan citationid=\"CR57\" class=\"CitationRef\"\u003e57\u003c/span\u003e], concluded that the framework with the low elastic modulus (PEKK) reduced the stress within the framework; however, it transmitted additional stress to the supra-structures of the prostheses and this was consistent with the finding of this study.\u003c/p\u003e \u003cp\u003eSimilarly, Tribst et al. [\u003cspan citationid=\"CR58\" class=\"CitationRef\"\u003e58\u003c/span\u003e] concluded that an increase in the elastic modulus of the framework decreased the stress transmitted to the implants and surrounding bone.\u003c/p\u003e \u003cp\u003eIn the study done by Shetty et al. [\u003cspan citationid=\"CR59\" class=\"CitationRef\"\u003e59\u003c/span\u003e] where full-arch implant supported prosthesis was evaluated with different frameworks by strain gauge analysis, PEEK demonstrated higher deformation values than ZrO2 and CoCr in the presence of cantilever which coincide with the finding of this study.\u003c/p\u003e \u003cp\u003eIn contrast to our study, Franco et al. [\u003cspan citationid=\"CR60\" class=\"CitationRef\"\u003e60\u003c/span\u003e] reported that the cross section of the PEEK splint has its effect on the response to the applied stresses. However, in this study the cross section effect wasn\u0026rsquo;t evaluated.\u003c/p\u003e \u003cp\u003eRegarding the clinical relevance, and based on the current study results, the biomechanical properties and behavior of the PEEK splint qualifies it to be used with the provisional restoration, keeping in mind that PEEK response to oblique load tends to accumulate rather than dispense the stresses along the splint body, so the usage of cantilever is not advised in such a case to avoid the risk of bending or even fracture of the splint. Additionally, the design of the implant platform, occlusal forces pattern, implant number and diameter have their effect on the pattern of the stress transmission [\u003cspan citationid=\"CR61\" class=\"CitationRef\"\u003e61\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eThough standardization and variables control can be obtained from finite element analysis studies. Yet, this study has many limitations. Static loading was applied for the purpose of simplification whereas loading is dynamic during the normal chewing functions. Moreover, it was proposed that all dental implants were fully Osseointegrated with bone, however, this does not mimic the clinical situation. And, the material properties of the bone were proposed to be linearly elastic and isotropic, however, this does not coincide with the living tissue simulation [\u003cspan citationid=\"CR32\" class=\"CitationRef\"\u003e32\u003c/span\u003e].\u003c/p\u003e"},{"header":"CONCLUSION","content":"\u003cp\u003eWithin the limitations of our study and the outcomes obtained, it was concluded that the behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability\u003c/p\u003e"},{"header":"Abbreviations","content":"\u003cp\u003eSTL: Standard tessellation language; SEqv: Equivalent stresses; Von‑Mises stress; spread; N: Newton; MPa: Mega Pascal, PEEK: polyetheretherketone.\u0026nbsp;\u003c/p\u003e\n"},{"header":"Declarations","content":"\u003cp\u003e\u003cstrong\u003eClinical trial number\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003e\u0026nbsp;Not applicable.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAcknowledgements\u0026nbsp;\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eNot applicable.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor contributions\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003e\u0026nbsp;LFZM: Conceptualization, methodology, writing\u0026mdash;original draft, writing\u0026mdash; review and editing, data curation.HTM: writing\u0026mdash;review and editing, data curation.HIE: writing\u0026mdash;review and editing, software, analysis SSM: Methodology, software, analysis, writing\u0026mdash;review and editing. RMA: Conceptualization, methodology, writing original draft, writing\u0026mdash;review and editing, data curation All authors have read and approved the manuscript.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunding\u0026nbsp;\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eOpen access funding provided by The Science, Technology \u0026amp; Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailability of data and materials\u003c/strong\u003e\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eAll data generated or analyzed during this study are provided within the manuscript.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eEthics approval and consent to participate\u003c/strong\u003e\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eNot applicable\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eConsent for publication\u003c/strong\u003e\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eNot applicable.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompeting interests\u003c/strong\u003e\u003cstrong\u003e\u0026nbsp;\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThe authors of the current study declare that they have no competing interests\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor details\u0026nbsp;\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003e1 Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo 11561, Egypt. 3 Oral and Maxillofacial Prosthodontics department. School of Dentistry, NewGiza University. Giza, Egypt\u003cstrong\u003e\u0026nbsp;\u003c/strong\u003e\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\n\u003cli\u003eWeerapong K, Sirimongkolwattana S, Sastraruji T, Khongkhunthian P\u003cstrong\u003e. \u003c/strong\u003eComparative study of immediate loading on short dental implants and conventional dental implants in the posterior mandible: A randomized clinical trial. INT J ORAL MAX IMPL. 2019;34(1).\u003c/li\u003e\n\u003cli\u003eZhang S, Wang S, Song Y.2017.Immediate loading for implant restoration compared with early or conventional loading: A meta-analysis. J Craniomaxillofac Surg. 45(6):793\u0026ndash;803.\u003c/li\u003e\n\u003cli\u003eSchnitman PA, Wohrle PS, Rubenstein JE\u003cstrong\u003e. \u003c/strong\u003eImmediate fixed interim prostheses supported by two-stage threaded implants: methodology and results. J ORAL IMPLANTOL. 1990;16(2):96-105.\u003c/li\u003e\n\u003cli\u003eLin WS, Ercoli C: A technique for indirect fabrication of an implant-supported, screw-retained, fixed provisional restoration in the esthetic zone. J Prosthet Dent 2009;102:393-396 \u003c/li\u003e\n\u003cli\u003eConte GJ, Fagan MC, Kao RT: Provisional restorations: a key determinant for implant site development. J Calif Dent Assoc 2008;36:261-267\u003c/li\u003e\n\u003cli\u003eLin WS, Eckert SE. Clinical performance of intentionally tilted implants versus axially positioned implants: A systematic Review. Clin Oral Implants Res. 2018;29(3):78-105.\u003c/li\u003e\n\u003cli\u003eHassan NA, Elkhadem AH, Kaddah A, El Khourazaty NS. Prosthesis and implant survival in immediately loaded full arch restorations using fiber-reinforced versus non-reinforced temporary frameworks: a randomized clinical trial. Brazilian Dental Science. 2022;25(3)\u003c/li\u003e\n\u003cli\u003eSingh S, Palaskar JN, Mittal S\u003cstrong\u003e. \u003c/strong\u003eComparative evaluation of surface porosities in conventional heat polymerized acrylic resin cured by water bath and microwave energy with microwavable acrylic resin cured by microwave energy. Contemp. Clin. Dent.2013;4(2):147-51.\u003c/li\u003e\n\u003cli\u003eBanerjee R, Banerjee S, Prabhudesai PS, Bhide SV.Influence of the processing technique on the flexural fatigue strength of denture base resins: An: in vitro: investigation. Indian J Dent Res.;21(3):391-5.\u003c/li\u003e\n\u003cli\u003eKorsch M, Walther W, Hannig M, BartolsA.Evaluation of the surgical and prosthetic success of All-on-4 restorations: a retrospective cohort study of provisional vs. definitive immediate restorations. Int. J. Implant Dent.2021;7:1-1.\u003c/li\u003e\n\u003cli\u003eClelland NL, Lee JK, Bimbenet OC, Brantley WA.A three‐dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. J Prosthodont . 1995;4(2):95-100.\u003c/li\u003e\n\u003cli\u003eMal\u0026oacute; P, de Ara\u0026uacute;jo Nobre M, Petersson U, WigrenS.A pilot study of complete edentulous rehabilitation with immediate function using a new implant design: case series. Clin Implant Dent Relat Res. 2006;8(4):223-32.\u003c/li\u003e\n\u003cli\u003eLee HJ, de Mattias Sartori IA, Alc\u0026acirc;ntara PR, Vieira RA, Suzuki D, Font\u0026atilde;o FG, Tiossi R\u003cstrong\u003e. \u003c/strong\u003eImplant stability measurements of two immediate loading protocols for the edentulous mandible: rigid and semi-rigid splinting of the implants. Implant Dent. 2012;21(6):486-90.\u003c/li\u003e\n\u003cli\u003eFayyad A.Prosthetic complications in immediately loaded All-on-Four mandibular prosthesis using titanium wire reinforcement versus non reinforced temporary framework. A Randomized Clinical Trial. Egypt. Dent. J.2022;68(1):885-92.\u003c/li\u003e\n\u003cli\u003eFogli V, Camerini M, Lauritano D, Carinci F.Success and high predictability of intraorally welded titanium bar in the immediate loading implants. Case Rep. Dent. 2014;2014(1):215378. \u003c/li\u003e\n\u003cli\u003eShetty M, Hegde R, Adarsh N, Prabhu A. Immediate Rehabilitation of Edentulous Maxilla with a Definitive ProsthesisUtilizing an Intraorally Welded Titanium Framework. RGUHS J. Med. Sci. 2022;12(1). \u003c/li\u003e\n\u003cli\u003eGarg J, Dhawan P. Intraoral welding: A concept of immediate rehabilitation of edentulous arches-a primer. J. Prosthet. Implant Dent. 2020; 3(1):83.\u003c/li\u003e\n\u003cli\u003eToth JM. Biocompatibility of Polyaryletheretherketone Polymers. PEEK Biomaterials Handbook. 2012, p. 81-92. \u003c/li\u003e\n\u003cli\u003eKurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials. 2007;28:4845-69. \u003c/li\u003e\n\u003cli\u003eStawarczyk B, Eichberger M, Uhrenbacher J, Wimmer T, Edelhoff D, Schmidlin PR. Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J. 2015;34:7-12. \u003c/li\u003e\n\u003cli\u003eVillefort RF, Diamantino PJ, Von Zeidler SL, Borges AL, Saavedra GD, Tribst JP. Mechanical response of PEKK and PEEK as frameworks for implant-supported full-arch fixed dental prosthesis: 3D finite element analysis. Eur. J. Dent. 2022;16(01):115-21. \u003c/li\u003e\n\u003cli\u003eSuedam V, Moretti Neto RT, Sousa EA, Rubo JH. Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures. J. Appl. Oral Sci. 2016;24:114-20.\u003c/li\u003e\n\u003cli\u003eDos Santos MB, Da Silva Neto JP, Consani RL, Mesquita MF. Three‐dimensional finite element analysis of stress distribution in peri‐implant bone with relined dentures and different heights of healing caps. J. Oral Rehabil. 2011;38(9):691-6.\u003c/li\u003e\n\u003cli\u003eYamanishi Y, Yamaguchi S, Imazato S, Nakano T, Yatani H. Effects of the implant design on peri‐implant bone stress and abutment micromovement: three‐dimensional finite element analysis of original computer‐aided design models. J. Periodontol. 2014;85(9):e333-8.\u003c/li\u003e\n\u003cli\u003eLemos CA, Verri FR, Noritomi PY, Kemmoku DT, de Souza Batista VE, Cruz RS, de Luna Gomes JM, Pellizzer EP. Effect of bone quality and bone loss level around internal and external connection implants: A finite element analysis study. J. Prosthet. Dent. 2021;125(1):137-e1.\u003c/li\u003e\n\u003cli\u003eBramanti E, Cervino G, Lauritano F, Fiorillo L, D\u0026rsquo;Amico C, Sambataro S, Denaro D, Fam\u0026agrave; F, Ierardo G, Polimeni A, Cicci\u0026ugrave; M.FEM and von mises analysis on prosthetic crowns structural elements: Evaluation of different applied materials. Sci. World J. 2017; (1):1029574. \u003c/li\u003e\n\u003cli\u003e. Reddy MS, Sundram R, Abdemagyd HA. Application of finite element model in implant dentistry: A systematic review. J Pharm Bioallied Sci 2019;11:85.\u003c/li\u003e\n\u003cli\u003eAk\u0026ccedil;a KI, Iplik\u0026ccedil;ioğlu H. Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism. J. Oral Rehabil 2002;29(4):350-6.\u003c/li\u003e\n\u003cli\u003eGeng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001;85:585-98.\u003c/li\u003e\n\u003cli\u003ePandey A, Durrani F, Rai SK, Singh NK, Singh P, Verma R, Kumar J. Comparison between all-on-four and all-on-six treatment concepts on stress distribution for full-mouth rehabilitation using three-dimensional finite element analysis: A biomechanical studyJ. Indian Soc. Periodontol. 2023 1;27(2):180-8.\u003c/li\u003e\n\u003cli\u003eShivakumar S, Kudagi VS, Talwade P. Applications of finite element analysis in dentistry: A review. Int. J. Oral Health Sci. 2021;13(5):415-22.\u003c/li\u003e\n\u003cli\u003eMohamed AM, Askar MG, El Homossany ME. Stresses induced by one piece and two piece dental implants in All-on-4\u0026reg; implant supported prosthesis under simulated lateral occlusal loading: Non-linear finite element analysis study. BMC Oral Health. 2022; 22(1):196.\u003c/li\u003e\n\u003cli\u003eHassan NA, Elkhadem AH, Elkerdawy MW, Osman RB. Biomechanics of Different Types of PEEK as Implant Materials for Implant-Retained Mandibular Overdentures. Eur. j. prosthodont. restor. dent. 2022;30(2):113-20.\u003c/li\u003e\n\u003cli\u003eAgnini A, Agnini AM, Romeo D, Chiesi M, Pariente L, Stappert CF. Clinical investigation on axial versus tilted implants for immediate fixed rehabilitation of edentulous arches: preliminary results of a single cohort study. Clin Implant Dent Relat Res. 2014;16(4):527-39.\u003c/li\u003e\n\u003cli\u003eHimmlova L, K\u0026aacute;covsk\u0026yacute; A, Konvic̆kov\u0026aacute; S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent. 2004;91(1):20-5. \u003c/li\u003e\n\u003cli\u003eWinkler S, Morris HF, Ochi S. Implant survival to 36 months as related to length and diameter. Ann. Periodontol. 2000;5(1):22-31.\u003c/li\u003e\n\u003cli\u003eEazhil R, Swaminathan SV, Gunaseelan M, Kannan GV, Alagesan C. Impact of implant diameter and length on stress distribution in osseointegrated implants: A 3D FEA study. J Int Soc Prev Community Dent .2016;6(6):590-6.\u003c/li\u003e\n\u003cli\u003eMal\u0026oacute; P, de Ara\u0026uacute;jo Nobre M, Moura Guedes C, Almeida R, Silva A, Sereno N, Legatheaux J. Short‐term report of an ongoing prospective cohort study evaluating the outcome of full‐arch implant‐supported fixed hybrid polyetheretherketone‐acrylic resin prostheses and the All‐on‐Four concept. Clin Implant Dent Relat Res .2018;20(5):692-702.\u003c/li\u003e\n\u003cli\u003eAngelara K, Bratos M, Sorensen JA. Comparison of strength of milled and conventionally processed PMMA complete-arch implant-supported immediate interim fixed dental prostheses. J. Prosthet. Dent. 2023;129(1):221-7.\u003c/li\u003e\n\u003cli\u003eDesai SR, Koulgikar KD, Alqhtani NR, Alqahtani AR, Alqahtani AS, Alenazi A, Heboyan A, Fernandes GV, Mustafa M. Three-dimensional FEA analysis of the stress distribution on titanium and graphene frameworks supported by 3 or 6-implant models. Biomimetics. 2023;8(1):15.\u003c/li\u003e\n\u003cli\u003eOsman RB, Elkhadem AH, Ma S, Swain MV. Finite element analysis of a novel implant distribution to support maxillary overdentures. Int J Oral Maxillofac Implants. 2013;28(1).\u003c/li\u003e\n\u003cli\u003eAltıparmak N, Polat S, Onat S. Finite element analysis of the biomechanical effects of titanium and Cfr-peek additively manufactured subperiosteal jaw implant (AMSJI) on maxilla. J Stomatol Oral Maxillofac Surg, Oral and Maxillofacial Surgery. 2023;124(1):101290.\u003c/li\u003e\n\u003cli\u003eRubo JH, Capello Souza EA. Finite‐element analysis of stress on dental implant prosthesis. Clin Implant Dent Relat Res. 2010;12(2):105-13. \u003c/li\u003e\n\u003cli\u003eFazi G, Tellini S, Vangi D, Branchi R. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis. Int J Oral Maxillofac Surg. 2011;26(4).\u003c/li\u003e\n\u003cli\u003eMeri\u0026ccedil; G, Erkmen E, Kurt A, Tun\u0026ccedil; Y, Eser A. Influence of prosthesis type and material on the stress distribution in bone around implants: A 3-dimensional finite element analysis. J. Dent. Sci. 2011;6(1):25-32.\u003c/li\u003e\n\u003cli\u003eAssun\u0026ccedil;\u0026atilde;o WG, Gomes EA, Barao VA, Delben JA, Tabata LF, de Sousa EA. Effect of superstructure materials and misfit on stress distribution in a single implant-supported prosthesis: a finite element analysis. J Craniofac Surg. 2010;21(3):689-95.\u003c/li\u003e\n\u003cli\u003eDayan SC, Geckili O. The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis. Comput. Methods Biomech. Biomed. Engin. 2021;24(14):1606-17.\u003c/li\u003e\n\u003cli\u003e\u0026Ccedil;ift\u0026ccedil;i Y, Canay Ş. Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials. Int J Prosthodont. 2001;14(5).\u003c/li\u003e\n\u003cli\u003eSertg\u0026ouml;z A. Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis Int J Prosthodont. 1997;10(1). \u003c/li\u003e\n\u003cli\u003eAboelnagga MM. Comparative stress analysis of BioHPP and PEKK CAD/CAM frameworks in mandibular All-on-Four fixed-detachable prosthesis on its supporting implants. ASDJ. 2023;32(4):6-18.\u003c/li\u003e\n\u003cli\u003eEl-Rahman A, Aladdin N, El-Sharkawy AM, Mohy El-Din MH, Saad MS. Strain evaluation of peek cantilever bars around implants assisted mandibular overdentures (in vitro study). ADJALEXU. 2022;47(3):138-45.\u003c/li\u003e\n\u003cli\u003eErs\u0026ouml;z MB, Mumcu E. Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study. J Adv Prosthodont .2022;14(6):346. \u003c/li\u003e\n\u003cli\u003eJaros OA, De Carvalho GA, Franco AB, Kreve S, Lopes PA, Dias SC. Biomechanical behavior of an implant system using polyether ether ketone bar: Finite element analysis. J Int Soc Prev Community Dent. 2018;8(5):446-50.\u003c/li\u003e\n\u003cli\u003eElkhooly AS, Elmasry SM, Mohamed ME, Zaky SZ. Effect of PEKK and Bio-HPP CAD-CAM Materials on Stress Distribution around Implants in Bar-Retained Implant-Supported Prostheses. Sapporo Med. J.2024;58(7).\u003c/li\u003e\n\u003cli\u003eYu W, Chen S, Ma L, Ma X, Xu X. Biomechanical Analysis of Different Framework Design, Framework Material and Bone Density in the Edentulous Mandible With Fixed Implant‐Supported Prostheses: A Three‐Dimensional Finite Element Study. J. Prosthodont. 2023;32(4):309-17. \u003c/li\u003e\n\u003cli\u003eJacques LB, Moura MS, Suedam V, Souza EA, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular‐cantilevered implant‐supported prostheses. Clin. Oral Implants Res. 2009;20(7):737-41. \u003c/li\u003e\n\u003cli\u003eLee KS, Shin SW, Lee SP, Kim JE, Kim JH, Lee JY, Lee KS, Shin SW, Lee SP, Kim JE, Kim JH. Comparative Evaluation of a Four-Implant-Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design. Int J Prosthodont. 2017;30(6). \u003c/li\u003e\n\u003cli\u003eTribst JP, Campanelli de Morais D, Melo de Matos JD, Lopes GD, Dal Piva AM, Souto Borges AL, Bottino MA, Lanzotti A, Martorelli M, Ausiello P. Influence of framework material and posterior implant angulation in full-arch all-on-4 implant-supported prosthesis stress concentration. Dent. J. 2022;10(1):12. \u003c/li\u003e\n\u003cli\u003eShetty R, Singh I, Sumayli HA, Jafer MA, Feroz SA, Bhandi S, Raj AT, Patil S, Ferrari M. Effect of prosthetic framework material, cantilever length and opposing arch on peri-implant strain in an all-on-four implant prostheses. Niger. J. Clin. Pract. 2021;24(6):866-73. \u003c/li\u003e\n\u003cli\u003eFranco AG, de Carvalho GA, Dias SC, Ramos EV, Franco AB. Different protocol bar designs made of polyether ether ketone (PEEK) and metal: an analysis of mechanical behavior: Mechanical behavior of three PEEK infrastructures. IAJMH. 2022; 5:1-8.\u003c/li\u003e\n\u003cli\u003eG\u0026ouml;re E, Evlioğlu G. Assessment of the effect of two occlusal concepts for implant-supported fixed prostheses by finite element analysis in patients with bruxism. J Oral Implantol. 2014;40(1):68-75.\u003c/li\u003e\n\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":false,"highlight":"","institution":"","isAcceptedByJournal":true,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"[email protected]","identity":"scientific-reports","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"scirep","sideBox":"Learn more about [Scientific Reports](http://www.nature.com/srep/)","snPcode":"","submissionUrl":"","title":"Scientific Reports","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Scientific Reports","inReviewEnabled":true,"inReviewRevisionsEnabled":true},"keywords":"Immediate loading, framework, splinting, PEEK, intraoral welding","lastPublishedDoi":"10.21203/rs.3.rs-5183274/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-5183274/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003e\u003cb\u003eBackground\u003c/b\u003e\u003c/p\u003e \u003cp\u003eFull arch fixed provisional restorations are prone to fracture during function for several reasons. Those types of fractures during the healing period eliminate the cross-arch stabilization and disrupt stress distribution patterns.\u003c/p\u003e\u003cp\u003e\u003cb\u003eMethods\u003c/b\u003e\u003c/p\u003e \u003cp\u003eFEA (Finite Element Analysis) study was carried out using edentulous maxillary models where implants and other components were represented in three dimensional (3D) geometric models. Two 3D FEA models with six implants were used. Model TB: the implants were splinted with welded titanium bar; Model PB: the implants were splinted with PEEK (Poly Ether Ether Ketone) bar. An interim full arch PMMA (Poly methyl methacrylate) prosthesis was virtually designed for both models. Both models were subjected to vertical and oblique forces with a single force magnitude of 100 N. The amount of maximum equivalent Von-Mises stresses was calculated at the cervical part of the bone cylinder (marginal bone) and both frameworks.\u003c/p\u003e\u003cp\u003e\u003cb\u003eResults\u003c/b\u003e\u003c/p\u003e \u003cp\u003eUnder bilateral vertical loading, stresses were found to be comparable at the marginal bone between titanium and PEEK splinting. The PEEK framework had better and lower stress distribution than the titanium. While under unilateral oblique forces PEEK had better mechanical response on the marginal bone. And PEEK framework itself showed higher stresses than the titanium.\u003c/p\u003e\u003cp\u003e\u003cb\u003eConclusion\u003c/b\u003e\u003c/p\u003e \u003cp\u003eThe behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability\u003c/p\u003e","manuscriptTitle":"Finite Element Analysis of Welded Titanium Bar and Poly Ether Ether Ketone Bar in Maxillary Full Arch Splinted Interim Prosthesis","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2025-04-15 11:14:06","doi":"10.21203/rs.3.rs-5183274/v1","editorialEvents":[{"type":"communityComments","content":0},{"type":"decision","content":"Accepted","date":"2025-04-22T12:19:49+00:00","index":"","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2025-04-15T18:31:10+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"52332159204282479279028164855279523984","date":"2025-04-14T13:16:07+00:00","index":"hide","fulltext":""},{"type":"reviewersInvited","content":"","date":"2025-04-14T11:59:26+00:00","index":"","fulltext":""},{"type":"checksComplete","content":"","date":"2025-04-11T06:26:28+00:00","index":"","fulltext":""},{"type":"submitted","content":"Scientific Reports","date":"2025-03-28T21:52:29+00:00","index":"","fulltext":""}],"status":"published","journal":{"display":true,"email":"[email protected]","identity":"scientific-reports","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"scirep","sideBox":"Learn more about [Scientific Reports](http://www.nature.com/srep/)","snPcode":"","submissionUrl":"","title":"Scientific Reports","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Scientific Reports","inReviewEnabled":true,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"fba9474a-f32b-4389-b2ee-9f779346e8fb","owner":[],"postedDate":"April 15th, 2025","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"published-in-journal","subjectAreas":[{"id":47186799,"name":"Health sciences/Medical research"},{"id":47186800,"name":"Physical sciences/Materials science"}],"tags":[],"updatedAt":"2025-05-12T15:58:32+00:00","versionOfRecord":{"articleIdentity":"rs-5183274","link":"https://doi.org/10.1038/s41598-025-99750-x","journal":{"identity":"scientific-reports","isVorOnly":false,"title":"Scientific Reports"},"publishedOn":"2025-05-09 15:56:56","publishedOnDateReadable":"May 9th, 2025"},"versionCreatedAt":"2025-04-15 11:14:06","video":"","vorDoi":"10.1038/s41598-025-99750-x","vorDoiUrl":"https://doi.org/10.1038/s41598-025-99750-x","workflowStages":[]},"version":"v1","identity":"rs-5183274","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-5183274","identity":"rs-5183274","version":["v1"]},"buildId":"8U1c8b4HqxoKbykW_rLl7","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00