A Comparison of Tissue Spray and Lipid Extract Direct Injection Electrospray Ionization Mass Spectrometry for the Differentiation of Eutopic and Ectopic Endometrial Tissues

other OA: closed public-domain-us
View on PubMed View at publisher

Abstract

Recent research revealed that tissue spray mass spectrometry enables rapid molecular profiling of biological tissues, which is of great importance for the search of disease biomarkers as well as for online surgery control. However, the payback for the high speed of analysis in tissue spray analysis is the generally lower chemical sensitivity compared with the traditional approach based on the offline chemical extraction and electrospray ionization mass spectrometry detection. In this study, high resolution mass spectrometry analysis of endometrium tissues of different localizations obtained using direct tissue spray mass spectrometry in positive ion mode is compared with the results of electrospray ionization analysis of lipid extracts. Identified features in both cases belong to three lipid classes: phosphatidylcholines, phosphoethanolamines, and sphingomyelins. Lipids coverage is validated by hydrophilic interaction liquid chromatography with mass spectrometry of lipid extracts. Multivariate analysis of data from both methods reveals satisfactory differentiation of eutopic and ectopic endometrium tissues. Overall, our results indicate that the chemical information provided by tissue spray ionization is sufficient to allow differentiation of endometrial tissues by localization with similar reliability but higher speed than in the traditional approach relying on offline extraction. Graphical Abstract ᅟ.

My notes (saved in your browser only)

Condition tags

endometriosis

MeSH descriptors

Endometrium Lipids Spectrometry, Mass, Electrospray Ionization Chromatography, Liquid Chromatography, Liquid Endometriosis Endometriosis Endometrium Endometrium Female Humans Hydrophobic and Hydrophilic Interactions Lipids Phosphatidylcholines Phosphatidylcholines Phosphatidylethanolamines Phosphatidylethanolamines Spectrometry, Mass, Electrospray Ionization Sphingomyelins Sphingomyelins

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-06-11T06:19:48.454388+00:00
pubmed
last seen: 2026-05-13T22:20:13.663096+00:00
unpaywall
last seen: 2026-05-14T19:30:52.867331+00:00
License: public-domain-us · commercial use OK · attribution required
Courtesy of the U.S. National Library of Medicine