Three-dimensional ultrasound VOCAL combined with contrast-enhanced ultrasound: an alternative to contrast-enhanced magnetic resonance imaging for evaluating ablation of benign uterine lesions
other
OA: gold
CC-BY-4.0
Abstract
OBJECTIVE: This study explores the feasibility and value of three-dimensional ultrasound virtual organ computer-aided analysis (3D-VOCAL) combined with contrast-enhanced ultrasound (CEUS) for measuring the non-perfused volume (NPV) after microwave ablation (MWA) of benign uterine lesions.
METHODS: Fifty-six patients with uterine myoma (UM) and adenomyosis (AM) treated with MWA were enrolled. NPV measurements were obtained postoperatively using two-dimensional CEUS (2D-CEUS), 3D-VOCAL combined with CEUS and three-dimensional contrast-enhanced magnetic resonance imaging (3D-CEMRI). Bland-Altman analysis and intraclass correlation coefficient (ICC) values were used to analyze the agreement of NPV measurements obtained via 2D-CEUS and the combined method with 3D-CEMRI. The inter- and intra-observer agreements of the NPV values obtained with all three methods were also analyzed.
RESULTS: Considering 3D-CEMRI as the standard, 3D-VOCAL showed greater agreement than 2D-CEUS and higher ICCs (ICC, 0.999 vs. 0.891) than 2D-CEUS for different lesion types and sizes of non-perfusion areas (p < 0.001 for all comparisons). NPV measurements obtained via 2 D-CEUS and 3 D-CEMRI differed significantly for AM and non-perfusion areas with maximum diameter ≥5 cm (p 0.05) for UM and non-perfusion areas with maximum diameter 0.05). The intra- and inter-observer agreements of 3D-VOCAL measurements were better than those of 2D-CEUS and slightly lower than those of 3D-CEMRI.
CONCLUSIONS: 3D-VOCAL combined with CEUS provides accurate estimates of NPV after MWA of benign uterine lesions, and offers a reliable, simple and efficient alternative to CEMRI.
My notes (saved in your browser only)
Condition tags
MeSH descriptors
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-06-21T06:12:49.409960+00:00
- pubmed
- last seen: 2026-06-21T06:12:22.775504+00:00
- unpaywall
- last seen: 2026-05-14T19:30:52.867331+00:00
License: CC-BY-4.0
· commercial use OK
· attribution required
Courtesy of the U.S. National Library of Medicine
Courtesy of the U.S. National Library of Medicine