Embolization of meningiomas: comparison of safety between calibrated microspheres and polyvinyl-alcohol particles as embolic agents

Non-randomised trial OA: closed
📄 Open PDF View on PubMed View at publisher
⚙ AI-generated summary by qwen3.7-flash, 2026-09-13 ⓘ

Embolization of meningiomas using 400-μm calibrated microspheres resulted in zero hemorrhagic complications, showing a non-significant trend toward lower complication rates compared to historical cohorts treated with smaller polyvinyl-alcohol particles.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

BACKGROUND AND PURPOSE: During embolization of meningiomas, intratumoral hemorrhagic complications may occur, especially with the use of small particle sizes. We compared the rate of hemorrhagic complications in 55 patients embolized with 400-μm calibrated microspheres (Embozene) with a historical cohort of 198 patients embolized with smaller PVA particles. MATERIALS AND METHODS: Between September 2009 and February 2012, fifty-five patients with 55 meningiomas were embolized with 400-μm calibrated microspheres. Indications for embolization were preoperative in 47 and before radiosurgery in 2 patients; and in 6 patients, embolization was offered as sole therapy. There were 35 women and 20 men with a mean age of 60.3 years. Mean meningioma diameter was 53 mm (range, 23-97 mm). Hemorrhagic complications were recorded. RESULTS: There were no hemorrhagic complications in the 55 embolized patients (0%; 95% CI, 0.0%-7.8%). The difference in complication rates between 400-μm calibrated microspheres in this study (0 of 55, 0%) and small PVA particles (45-150 μm) in the historical cohort (9 of 108, 8.3%) was just short of significance (P=.066). The difference in complication rates between 400-μm calibrated microspheres (0 of 55, 0%) and larger PVA particles (150-250 μm) in the historical cohort (1 of 93, 1.1%) was not significant (P=.8). CONCLUSIONS: In this series, embolization of meningiomas by using large (400-μm) calibrated microspheres did not result in any hemorrhagic complications.

My notes (saved in your browser only)

MeSH descriptors

Embolization, Therapeutic Embolization, Therapeutic Meningeal Neoplasms Meningioma Microspheres Polyvinyl Alcohol Adult Aged Aged, 80 and over Brain Ischemia Brain Ischemia Calibration Cerebral Hemorrhage Cerebral Hemorrhage Cohort Studies Embolization, Therapeutic Female Humans Male Meningeal Neoplasms

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-10-11T09:27:45.537177+00:00
pubmed
last seen: 2026-10-08T21:10:53.858194+00:00