A narrative review of fluorescence imaging in robotic-assisted surgery.

OA: gold CC-BY-NC-ND-4.0
AI-generated summary by qwen3.7-flash, 2026-08-31

This narrative review examines the applications of Firefly fluorescence imaging in robotic-assisted urologic, gynecologic, general, and endocrine surgeries, highlighting its potential to guide surgical interventions and aid decision-making through real-time intraoperative visualization.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

AI-generated deep summary by qwen3.7-flash, 2026-08-31 · read from full text

This narrative review examines the evolution and clinical applications of fluorescence imaging, particularly using indocyanine green, within robotic-assisted surgery systems like the da Vinci platform. The authors detail how this technology has been integrated into various surgical subspecialties, including urology and gynecologic oncology, to enhance visualization of blood perfusion, identify sentinel lymph nodes, and delineate tissue boundaries during procedures such as partial nephrectomy and pelvic reconstruction. While the paper highlights significant benefits in precision and safety across these fields, it notes that certain diagnostic uses, such as predicting tumor malignancy via fluorescence alone, have not been reliably validated in larger studies. Relevance to endometriosis: listed as one indication for GnRH antagonists, though the paper's main focus is uterine fibroids.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Abstract

ObjectiveIn this review, we provide examples of applications of fluorescence imaging in urologic, gynecologic, general, and endocrine surgeries.BackgroundWhile robotic-assisted surgery has helped increase the availability of minimally invasive procedures across surgical specialties, there remains an opportunity to reduce adverse events associated with open, laparoscopic, and robotic-assisted methods. In 2011, fluorescence imaging was introduced as an option to the da Vinci Surgical System, and has been standard equipment since 2014. Without interfering with surgical workflow, this fluorescence technology named Firefly® allows for acquisition and display of near-infrared fluorescent signals that are co-registered with white light endoscopic images. As a result, robotic surgeons of all specialties have been able to explore the clinical utility of fluorescence guided surgery.MethodsLiterature searches were performed using the PubMed and MEDLINE databases using the keywords "robotic-assisted fluorescence surgery", "ICG robotic surgery", and "fluorescence guided surgery" covering the years 2011-2020.ConclusionsReal-time intraoperative fluorescence guidance has shown great potential in helping guide surgeons in both simple and complex surgical interventions. Indocyanine green is one of the most widely-used imaging agents in fluorescence guided surgery, and other targeted, near-infrared imaging agents are in various stages of development. Fluorescence is becoming a reliable tool that can help surgeons in their decision-making process in some specialties, while explorations continue in others.
Full text 29,301 characters · extracted from pmc-nxml · 3 sections · click to expand

Methods

Literature searches were performed using the PubMed and MEDLINE databases using the keywords “robotic-assisted fluorescence surgery”, “ICG robotic surgery”, and “fluorescence guided surgery” covering the years 2011–2020. In 2011, Intuitive Surgical received 510 k clearance to market the da Vinci Fluorescence Vision Imaging System as part of the da Vinci Si Surgical System. Key components of the Fluorescence Vision Imaging System included 8- and 12-mm endoscopes with lens stacks modified to allow the passage of NIR light, a stereoscopic camera head with the appropriate blocking filters for ICG, a light emitting diode (LED)-based illuminator with a NIR laser to excite ICG, in addition to a procedure kit containing ICG, aqueous solvent, and syringes. Minor software modifications were made to enable the da Vinci to recognize and allow use of the fluorescence feature. The intended use was to perform minimally invasive surgery using standard endoscopic visible light as well as NIR imaging for visual assessment of vessels, blood flow and related tissue perfusion. Engineering and testing of the device was performed by employees of Intuitive Surgical and its suppliers; however, the development was enhanced through a partnership and equipment supply agreement with Novadaq Technologies. The Fluorescence Vision Imaging System remained an optional add-on to the da Vinci Si and was later renamed da Vinci Firefly ® . In 2013, Firefly ® received a 510-k clearance for an expanded intended use to include visualization of at least one of the major extra-hepatic bile ducts (cystic duct, common bile duct and common hepatic duct) using NIR imaging. The clearance specifically stated that fluorescence imaging of biliary ducts with the da Vinci Firefly ® is intended for use in conjunction with standard of care white light when indicated for intraoperative cholangiography. The device is not intended for standalone use for biliary duct visualization. In 2014, the da Vinci Xi system was released as the 4 th generation Surgical System. The illumination and endoscopic imaging systems were redesigned from the ground-up to incorporate a CMOS sensor in a distal chip architecture, as opposed to the rod-lens endoscope coupled to an external CCD-based camera in the previous da Vinci Si model. Although the intended use statement for the Firefly ® system remained the same, the Firefly ® system was included on every Xi as standard equipment. This remained the case for the da Vinci X Surgical System upon its release in 2017. Applications of fluorescence imaging in robotic-assisted surgery across various surgical subspecialties are summarized in Table 1 and detailed below. Prior to the introduction of Firefly ® , several academic groups experimented with adding fluorescence capabilities to the da Vinci, van der Poel was the first to perform fluorescence guided surgery using the da Vinci S Surgical System and a Storz fluorescence laparoscope (Karl Storz, Tuttlingen, Germany) to intraoperatively identify sentinel lymph nodes via fluorescence imaging following a preoperative injection of ICG-99mTc-nanocolloid mixture directly into the peripheral zone of the prostate ( 12 ). This study was important for two reasons: (I) the da Vinci S system that was used pre-dated Firefly ® , and the lymphatic mapping was performed solely using a Storz system; (II) since the NIR signal of ICG rarely penetrates more than 8 mm in human tissue, the idea of exploiting the deeper tissue penetrating (4–5 cm) gamma rays of technetium-99 has the potential to further aid in lymph node detection as it provides the surgeon with an intraoperative roadmap, which is particularly helpful in cases where lymph node drainage may be expected to areas outside of the standard pattern ( 13 ). While lymphangiography has been demonstrated in prostate surgery using Firefly ® and robotic-guided percutaneous injections of ICG highlighted potential sentinel nodes in 76% of patients ( 14 ), sentinel lymph node dissection is nowhere near replacing traditional pelvic lymph node dissection. The technique may be relevant in reducing lymphedema in certain patient populations with limited potential for positive nodes. Urologists have also used ICG to help guide lymph node dissection in robotic penile cancer procedures ( 15 ). The first published use of the integrated Firefly ® system sought to improve the safety of robotic-assisted partial nephrectomy procedures through the use of perfusion assessment, as more than 40% of kidneys have an abnormal vascular supply ( 16 ). Vessels were clearly visualized, as shown in Figure 1 , and the use of fluorescence to guide selective clamping was demonstrated. This and other groups took further advantage of the reported reduction of bilitranslocase in renal cortical tumors to image the boundaries of healthy and abnormal kidney, as bilitranslocase had been reported to be responsible for the accumulation of ICG in healthy renal cells, leaving tumor cells without a fluorescence signal, as shown in Figure 2 ( 17 ). The results of this pilot study showed 83% concordance between decreased fluorescence and presence of tumor, although subsequent larger studies confirmed that ICG-fluorescence cannot, on its own, predict tumor malignancy reliably ( 18 ). The concept of “zero ischemia time” in kidney surgery, where the surgeon attempts to preserve blood flow to the normal kidney while selectively cutting off blood flow to tumor tissue, is often described as a “super selective” technique. Previously performed using radiographically-guided embolization techniques ( 19 , 20 ), urologists took advantage of robotics to perform selective microdissections of vasculature to achieve similar goals ( 21 ). The da Vinci Firefly ® technology helped surgeons perform partial nephrectomies in greater numbers than before, and improved instrument dexterity facilitated easier microvascular dissection. Fluorescence imaging to confirm microdissection techniques for zero ischemia time during partial nephrectomy procedures was first described by Borofsky ( 22 ), where 80% of patients underwent super selective clamping. Prospective studies have shown a reduction in warm ischemia time by two minutes when using ICG, with no increase in positive surgical margins or complication rates ( 23 ). Urologists operating on kidneys quickly observed that the adrenal gland exhibited strong fluorescence while masses such as lipoadenomas, pheochromocytomas, and lymphoid hyperplasia exhibited hypofluorescence ( 24 , 25 ). Adrenocortical tumors were hyperfluorescent when compared to surrounding tissues. Differentiation of adrenal masses was evident 5 minutes after ICG injection and persisted for approximately 20 minutes. This phenomenon was attributed to differences in vascular perfusion between the different types of tissues and was used to preserve adrenal function while removing masses, leading to improved quality of life and a reduced need for adjuvant steroid therapy. Colvin et al . postulated that ICG-based fluorescence imaging increased the precision of dissection of the tumors when compared to white light imaging alone ( 26 ), leading to reduced bleeding from the tumor, better awareness of vascular structures, and more complete removal of adrenal tissue when indicated. While considered to be off-label, several groups have demonstrated the ability of ICG to light up the ureters when injected directly into them above and below a stenosis during the course of a ureteroureterostomy, as demonstrated in Figure 3 ( 27 ). Fluorescence guidance was found to be particularly useful in cases involving fibrosis, difficult dissection planes, and inflammation. The injection of small amounts of ICG into the ureters is a technique that has also been used for visualization during procedures in which ureteral injury can be an issue, such as sacrocolpopexy ( 28 ). This technique allowed bilateral ureter imaging throughout the entire pelvic reconstruction procedure and helped prevent ureteral damage without the need for full catheterization or stenting, further minimizing associated risks. Due to the fact that the Firefly ® system “pseudo-colors” NIR light into a green color, one group published on the use of the Firefly ® mode to visualize NIR emissions of traditional white light instruments, without the use of an exogenous contrast agent ( 29 ). By capitalizing on the fact that the da Vinci System displays normal anatomy in a grey color, surgeons used the guidance from a cystoscope to mark the borders of a bladder diverticula containing cancer in one case and gross tumor location in another. The light from a ureteroscope was used to identify the extent of ureteral stricture, once again by viewing the light of the ureteroscope from the pelvis using the da Vinci Firefly ® endoscope. Visualization of landmark arteries associated with the neurovascular bundle in prostatectomy has also been demonstrated to guide novice and more experienced surgeons becoming familiar with the nerve sparing technique ( 30 ). Groups began to explore the use of ICG for lymphatic mapping in gynecologic oncology cases by injecting ICG directly into the cervix to evaluate drainage patterns into lymph nodes ( 31 ), demonstrating detection of one sentinel draining node in 85% of patients. While direct tissue injection of ICG for lymphatic mapping does not fall within the approved indications for use statement of Firefly ® , this technique has been recommended in the NCCN guidelines for many years ( 32 ). The use of ICG for lymphatic mapping in gynecologic procedures is by far the most common use of the imaging agent in this specialty, given the improved ability to detect lymph nodes and the lack of disadvantages associated with radioactive tracers and blue dyes that can obscure the surgical field. Subsequent studies suggest that ICG provides superior visualization of nodes when compared to blue dye ( 33 , 34 ) although training on proper injection technique was crucial to obtaining good results. ICG has been used in studies to identify draining nodes in endometrial ( 35 ), cervical ( 36 ) and vulvar cancers. While lymph node detection decreases with increasing body mass index, ICG significantly improved the results when compared to blue dyes ( 37 ). Levey et al . demonstrated the potential use of ICG in identifying lesions while treating endometriosis ( 38 ), speculating that improved imaging would be necessary to properly treat the chronic pain associated with the disease. Cosentino took this idea further in a non-robotic setting, evaluating 27 patients and concluding that ICG is useful as an adjunct to white light imaging ( 39 ), while other groups have demonstrated ICG identifying more lesions than white light alone ( 40 ). Taking advantage of the known utility of using ICG to assess perfusion, the compound has been used to assess ureteral ( 41 ) and bowel perfusion ( 42 ) after resection of infiltrating endometriosis. Inspired by research in preclinical models in Japan with the Photodynamic Eye (Hamamatsu Photonics, Hamamatsu, Japan), general surgeons began using ICG to evaluate hepatobiliary anatomy, taking advantage of the elimination route of ICG after systemic injection and identifying small accessory vessels that would be difficult to visualize using white light alone ( 43 ). In this first documented use of ICG during robotic-assisted hepatobiliary surgery, an aberrant canaliculus from a liver segment to the common hepatic duct was identified and injury to the vessel was avoided, as illustrated in Figure 4 ( 43 ). Subsequent studies further evaluated the use of fluorescence-guided surgery in single site robotic-assisted cholecystectomies, where the dexterity of instruments is more limited compared to traditional multiport procedures, and ICG was useful in identifying the cystic, common hepatic and common bile ducts ( 44 , 45 ). Based on these findings, surgeons began to use ICG during simple cholecystectomies as well as in gallbladder cancer resections ( 46 ) and more complex liver surgeries ( 47 ) with the potential for avoiding abnormal vasculature during these procedures. Larger case studies demonstrated successful identification of at least one biliary structure in 99% of 184 cases, with 83% of cases detecting all four key anatomic ducts ( 48 ). With a low complication rate of 0.4–1.5% ( 49 , 50 ), bile duct injury is associated with a significantly increased length of stay, 30-day readmission rate, as well as risk of being discharged to a post-acute care facility. The cost of increased hospital stay alone has been estimated at approximately $10,420 ( 51 ), and up to 27% of injuries have been reported to be undetected during surgery ( 52 ). Some groups have experimented with using fluorescence to assist in registering structures such as the common bile duct and cystic duct to preoperative imaging scans for improved guidance using augmented reality during robotic duodenopancreatectomies ( 53 ). Anatomic dehiscence of the colon after low anterior resection is associated with higher mortality rates, increased hospital length of stay, in addition to cost ( 54 , 55 ). While many factors contribute to dehiscence, the state of perfusion of the bowel at the anastomotic site has been shown to be important ( 56 , 57 ) and was traditionally difficult to assess intraoperatively. The use of ICG to assess colorectal tissue perfusion during robotic-assisted colorectal surgery in real-time was first published by Bae, who reported visualizing the left colic branch of the inferior mesenteric artery in all attempted cases ( 58 ), and identification of the ischemic zone in the rectum helped the surgeon define the distal resection margin. A small retrospective study comparing colorectal resection with and without ICG reported a reduction in overall leak rate by 12% when fluorescence imaging was used ( 59 ), and ICG resulted in frequent revision of the bowel transection point, as shown in Figure 5 . A larger multicenter prospective clinical study (PILLAR-II) using laparoscopic equipment demonstrated a revision in the planned transection point in 8% of patients after fluorescence imaging, and a leak rate of 1.4%, which was lower than similar cohort comparison studies reported in the literature ( 60 ). None of the patients who experienced a revision after fluorescence imaging had an anastomotic leak. Unfortunately, the subsequently planned randomized control trial (PILLAR-III) was stopped due to slow accrual of patients. Recently, De Nardi et al . reported on the results of a multicenter randomized trial demonstrating ICG-based NIR fluorescence imaging leading to a change in the resection plane in 11% of cases ( 61 ). Although a difference in leak rates between the non-fluorescence-guided surgery group (9%) and the fluorescence-guide surgery group (5%) was found, this was not statistically significant. In sphincter-preserving rectal surgery, ICG helped identify an adequate perfusion margin in 10% of patients at risk of anastomotic site ischemia and reduced the leak rate to 0.8% compared with 5.4% in resections performed without fluorescence imaging ( 62 ). A larger study involving 657 patients demonstrated similar results ( 63 ). While quantification of the fluorescence signal remains complicated for a number of reasons, some groups are experimenting with analyzing the time course of arterial inflow and venous outflow patterns of ICG in the colon by comparing pre- and post-anastomosis signal intensity levels to that of known healthy colon ( 64 ). Similar to colorectal perfusion analysis, fluorescence assessment of gastric graft viability in robotic esophagectomy cases was first demonstrated by DeLong et al . ( 65 ), and studies to better understand the exact relationship between the signal from ICG and adequate perfusion are ongoing. General surgeons have reported using Firefly ® following colonoscopic injection of ICG to identify draining lymph nodes during complete mesocolic excision ( 66 ) and gastrectomy ( 67 ), where nodal status and nodal yield at the time of excision is key to cancer staging. Pilot studies have been performed using ICG for lymphatic mapping in gastric cancer as well, with increased lymph node yield when using fluorescence guidance ( 68 ). Comparison of single port fluorescence-guided robotic surgery to conventional distal gastrectomy in patients with early-stage gastric cancer demonstrated superior lymph node yield, which is important when the number of retrieved lymph nodes is a surrogate marker for long-term outcomes ( 69 ). Several groups have taken advantage of differences in tumor versus healthy tissue vasculature to image the kinetics of ICG to differentiate between tumor and normal tissue. It is thought that this method relies upon the enhanced permeability and retention effect (EPR), the resulting altered fluid transfer dynamics from the abnormal vasculature formed in tumor environments. This was first published using open fluorescence imaging systems in head and neck tumors ( 70 ). When administering ICG 24–48 hours preoperatively, metastatic pancreatic cancer lesions on the liver demonstrated fluorescence in 27% of patients; however, it was noted that benign, bile-secreting foci also exhibited fluorescence ( 71 ). This demonstrates a potential risk of using a non-targeted imaging agent to discern cancer from healthy tissue. Similar studies using ICG to detect intracranial meningioma showed high sensitivity but low specificity ( 72 ). In liver surgery, ICG has proven to be useful in characterizing well-differentiated hepatocellular carcinomas (HCC), poorly differentiated HCC, and colorectal metastases to the liver, which exhibited a rim fluorescence phenomenon ( 73 ). For HCC, the uptake transporters into hepatocytes remain the same, but cancerous cells have reduced ability to excrete ICG via the normal OATP1B3 and sodium-taurocholate co-transporting polypeptide. Nonetheless, this method of detecting lesions has a false positive rate as high as 40% ( 73 , 74 ). Subsequent studies have proposed an ideal imaging time of these tumors to be 1–2 days prior to surgery, to allow adequate clearance of ICG from healthy liver. Other studies have proposed that fluorescence guidance be used as an adjunct to intraoperative ultrasound to help reduce false positives after either an intravenous or portal vein injection. In such studies, while the sensitivity of fluorescence by itself ranged from 72–100% ( 75 ), an R0 resection was achieved 100% of the time ( 76 ). In terms of thoracic surgery, it remains unclear if segmentectomies have similar cancer control to lobectomies in early-stage lung cancer patients. Regardless, segmentectomy is technically more difficult than removing an entire lobe of the lung since the intersegmental plane must be identified. A variety of methods have been employed to make the identification easier: transbronchial ( 77 ) and intravenous ( 78 ) injection of ICG, selective segmental inflation ( 79 ), the use of 3D models ( 80 ), and infrared thoracoscopy have been proposed ( 81 ). Direct injection of ICG into a lesion via navigated bronchoscopy, while not an approved use of ICG, has been shown to help successfully localize tumors during robotically-assisted segmentectomies 86% of the time ( 82 ). Taking advantage of the EPR effect of ICG, thoracic surgeons have visualized sub-centimeter pulmonary nodules at a depth of around 0.5 cm by administering large amounts of ICG 24–48 hours prior to surgery using open, video-assisted thoracoscopic and robotic techniques ( 83 ). This technique may be of particular interest in robotic-assisted procedures where palpation of the tumor is not possible. As thyroidectomy has transitioned to a minimally invasive approach, difficulties in differentiating the thyroid from the parathyroid gland has emerged as a clinical need, as 50% of patients can develop transient hypoparathyroidism, with 1–5% developing the condition permanently ( 84 , 85 ). A recent publication used ICG to light up the parathyroid gland in patients undergoing a bilateral axillo-breast approach to thyroidectomy with the fluorescence-guided group having a significantly reduced rate of incidental hypoparathyroidism than the control group (0 vs . 16%) ( 86 ). The time kinetics of the fluorescence and dosing for adequate differentiation between the parathyroid and thyroid glands are under investigation, as some groups have described difficulty distinguishing between the two glands ( 87 ). Fluorescence has long been used in medical interventions with sodium fluorescein making up the bulk of procedures along with ICG. It has been used to guide neurosurgery ( 88 ), bladder biopsies ( 89 ), bronchoscopy ( 90 ), the healing of wounds ( 91 ), plaque ablation ( 92 ), and of course ophthalmology ( 93 ). While the bulk of fluorescence imaging in robot-assisted surgery has been performed using ICG due to the advantages of the NIR optical window, many other exciting imaging agents are in various phases of clinical development, most of which take advantage of the NIR imaging window of 650–1,350 nm, where optical scattering is the most dominant form of light interaction, as absorption by blood and water are minimized. The window is even more tight, as most imaging sensors have sharply reduced sensitivity beyond wavelengths of 1,000 nm. After van Dam et al ., reported on the efficacy of a folic acid fluorescein conjugate ( 94 ) that was subsequently changed to a NIR reporter, the field of fluorescent-guided surgery witnessed a resurgence. This new NIR folic acid conjugate, OTL-38 (On Target Laboratories, West Lafayette, IN, USA) has just completed phase III studies in ovarian cancer ( NCT03180307 ) and phase III studies in lung cancer are ongoing ( NCT04241315 ). In addition, various targeted ligands have been conjugated to novel fluorophores, such as IRDye800CW (LI-COR Biosciences, Lincoln, NE, USA), and are currently under clinical investigation in numerous phase I and II clinical studies in numerous tumor types, such as head and neck, pancreatic, breast, and brain cancers ( 95 – 99 ). In head and neck cancer, panitumumab and cetuximab ( 97 , 100 – 102 ) and olaparib for squamous cell carcinoma and bevacizumab for inverted papilloma and pituitary neuroendocrine tumors have been conjugated to IRDye800CW for detection of tumor and associated margins ( 99 ). These agents have promising applications in robotic fluorescence-guided surgery for head and neck squamous cell carcinoma, especially with the advent of transoral robotic surgery for oral and oropharyngeal tumors. Aforementioned groups have injected ICG directly into the ureters or even placed ICG-filled catheters into the ureters for visualization, although such techniques have been found impractical for widespread adoption ( 103 ). In recognition of the unmet clinical need, several imaging agents for visualizing the ureters have been designed specifically with robotic-assisted surgery in mind ( 104 – 106 ) and are in various phases of clinical development. For a comprehensive review of NIR imaging agents currently in clinical trials, the reader is referred to a recent review by Hernot et al . ( 107 ) and Barth et al . ( 99 ) While antibody-based fluorescence conjugates have traditionally been injected days prior to surgery, the current generation of small molecules and peptides can be injected as little as 10 minutes to two hours prior to the procedure, fitting in well with the operating room workflow ( 99 , 107 ). When the desired imaging agent does not overlap with the excitation and emission profile of ICG, certain groups have utilized other imaging endoscopes in concert with the da Vinci Surgical System. 5-aminolevulinic acid (5-ALA) is a natural metabolite in the body produced with the hemoglobin metabolic pathway. When taken up by malignant cells, 5-ALA is metabolized into a fluorescent byproduct, protoporphyrin IX, which can be visualized using 405 nm light. In 1998, Stummer et al . reported on the use of 5-ALA to guide brain tumor resections ( 108 ), and in 2017 the compound was approved for such use under the name Gleolan. In 2010, a different precursor to protoporphyrin IX, hexaminolevulinate was approved under the name Cysview to assist in bladder cancer resection(s). As a result, cystoscopes and endoscopes have been produced to image at these wavelengths. Robotic surgery was performed on prostate cancer patients using a protoporphyrin IX endoscope manufactured by Karl Storz to guide resection margins ( 109 ), based on data that prostate cancer cells selectively accumulated protoporphyrin IX ( 110 ). The investigators used the FDA-approved Tilepro ® feature of the da Vinci Surgical System, which allows a “picture in picture” type window to be displayed below the white light endoscopic image. These procedures were performed on a da Vinci System that pre-dated Firefly fluorescence, so the protoporphyrin IX image was displayed within Tilepro, allowing the surgeon to view the fluorescence image in the proper frame of reference. Subsequent studies demonstrated poor sensitivity and specificity in prostate cancer, and enthusiasm for the compound waned ( 111 ). As more targeted compounds are developed for imaging nerves, tumors, and other structures, it is likely that multiple wavelengths will need to be incorporated into robotic platforms. As more agents and devices are evaluated by the FDA as new drug applications or for clearance, respectively, the path for approval becomes clearer ( 112 – 115 ).

Conclusions

The integration of Firefly ® into the da Vinci Surgical System has facilitated robotic surgeons of all specialties to explore the potential value of fluorescence-guided surgery in their fields by allowing the acquisition of fluorescence imaging without disrupting their surgical workflow. While interesting findings have been published in nearly all surgical specialties regarding uses of fluorescence imaging, it has found greatest implementation in assessing colorectal perfusion, lymphatic mapping and visualizing hepatobiliary anatomy. The proliferation of laparoscopic and robotic endoscopes that easily co-register the white light and fluorescence image for use by the surgeon has helped to demonstrate a market for developers of targeted imaging agents, as the install base for these systems exceeds 10,000 units worldwide. As more targeted agents progress through clinical trials and gain FDA approval, the prevalence of the fluorescence platform will increase.

Introduction

The history of the cyanine dye, indocyanine green (ICG), as an indicator of cardiac and liver function has been well described ( 1 , 2 ). Equipment to image the near-infrared (NIR) emission of ICG has significantly lagged behind the discovery of the physical properties of the substance by approximately 30 years. One of the first endoscopes capable of imaging in the NIR region was described by Kohso in 1990 ( 3 ). Systems with the ability to measure tissue autofluorescence by laser spectroscopy were also produced in 1990 ( 4 , 5 ). Preclinical applications with other prototype NIR endoscopes followed, including imaging of resected gastric cancer using ICG-labeled anti-carcinoembryonic antigen (CEA) and MUC1 antibodies ( 6 ). Subsequently, NIR endoscopes were applied in the clinical setting, primarily in Japan, for imaging of sentinel lymph nodes in gastric cancer ( 7 ). The discovery and commercialization of the charge coupled device (CCD) enabled fluorescence imaging of ICG in open and endoscopic imaging systems, with videomicroscopy to image the arterial and venous capillaries of nailbeds ( 8 ), paving the way for subsequent macroperfusion devices. A decade later, the first prototype neurosurgical microscopes were designed with the ability to image in the NIR region ( 9 ), followed by commercial system availability within five years from known suppliers such as Leica and Zeiss. In 2005, Novadaq Technologies (Mississauga, Ontario, Canada) received FDA approval for the use of the SPY imaging system for coronary angiography, and clinicians started using ICG angiography to assess cardiac graft patency prior to chest closure given evidence demonstrating that upwards of 4% of grafts had problems requiring correction ( 10 ). While ICG has been used for over half a century for ophthalmic, neurologic, and angiographic applications, its introduction into surgical robotics came rather recently, as fluorescence imaging of ICG was introduced as an option to the da Vinci Si Surgical System after FDA clearance in 2011. While published reviews have described the application of fluorescence guidance in specific surgical specialties, we provide an overview of the use of the technique across all fields since the introduction of the technology in surgical robotics a decade ago. In addition to reviewing applications of fluorescence imaging in urologic, gynecologic, head and neck, general, and endocrine surgeries, we describe the evolution of fluorescence imaging technology on the da Vinci Surgical System. We present the following article in accordance with the Narrative Review reporting checklist (available at http://dx.doi.org/10.21037/ls-20-98 ).

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: pmc-nxml

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-09-06T09:34:12.023084+00:00
unpaywall
last seen: 2026-05-21T05:10:58.409756+00:00
License: CC-BY-NC-ND-4.0