High Resolution Multi-Pass Astral Analyzer Quantification Enables Highly Multiplexed 35-Plex Tandem Mass Tag Proteomics

preprint OA: closed
Full text JSON View at publisher

Abstract

ABSTRACT Tandem mass tags (TMT) allow highly multiplexed and thus high-throughput, precisely quantitative proteomic analysis. Incorporation of additional deuterated reporter channels has near-doubled the multiplexation achieved with Thermo Scientific™ TMTpro reagents from 18 to 35-plex but requires extremely high ∼100k analyzer resolving power at m/z 128 to differentiate and quantify reporter ion channels, far beyond any single reflection time-of-flight analyzer, and exceeding the multi-reflection Thermo Scientific™ Astral™ analyzer in its standard operation. A multi-pass mode of Astral operation has been developed for the Thermo Scientific™ Orbitrap™ Astral™ Zoom mass spectrometer that triples the ion path to 90 m, more than doubling resolving power for a narrow m/z range. This “TMT HR mode” has been integrated into a new method of TMT proteomic analysis that splits regular MS2 analysis of labeled peptides into paired measurements comprising wide mass range scans for peptide identification, and TMT HR mode scans for reporter ion quantification. The method has been shown to accurately quantify 32-plex labeled HeLa protein lysate and provide far greater depth of analysis as state-of-the-art Orbitrap-only methods, while analysis of 11-plex labeled yeast showed no analytical depth sacrificed vs regular Orbitrap Astral TMT analysis. Further comparative measurements of a 2-cell line 35-plex sample demonstrated greater analytical depth, and similar quantitative precision, to “gold standard” Orbitrap MS3 methods.
Full text 1,848 characters · extracted from oa-doi-fallback · click to expand
ABSTRACT Tandem mass tags (TMT) allow highly multiplexed and thus high-throughput, precisely quantitative proteomic analysis. Incorporation of additional deuterated reporter channels has near-doubled the multiplexation achieved with Thermo Scientific™ TMTpro reagents from 18 to 35-plex but requires extremely high ∼100k analyzer resolving power at m/z 128 to differentiate and quantify reporter ion channels, far beyond any single reflection time-of-flight analyzer, and exceeding the multi-reflection Thermo Scientific™ Astral™ analyzer in its standard operation. A multi-pass mode of Astral operation has been developed for the Thermo Scientific™ Orbitrap™ Astral™ Zoom mass spectrometer that triples the ion path to 90 m, more than doubling resolving power for a narrow m/z range. This “TMT HR mode” has been integrated into a new method of TMT proteomic analysis that splits regular MS2 analysis of labeled peptides into paired measurements comprising wide mass range scans for peptide identification, and TMT HR mode scans for reporter ion quantification. The method has been shown to accurately quantify 32-plex labeled HeLa protein lysate and provide far greater depth of analysis as state-of-the-art Orbitrap-only methods, while analysis of 11-plex labeled yeast showed no analytical depth sacrificed vs regular Orbitrap Astral TMT analysis. Further comparative measurements of a 2-cell line 35-plex sample demonstrated greater analytical depth, and similar quantitative precision, to “gold standard” Orbitrap MS3 methods. Competing Interest Statement The authors declare the following competing financial interest(s): HS, CR, JK, MZ, TNA, BH, ED, RO, DG, JP, DN, PC, FB, BD, MW, AW, RB, DCF, ED, AM, VZ and CH are employees of, and SPG a consultant for, Thermo Fisher Scientific, the manufacturer of instrumentation used in this research.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00