ABSTRACT Objective A catheter-free, non-radiolabeled method that permits in vivo measurement of tissue-specific glucose uptake does not exist. To address this gap, we sought to develop and validate a new, higher throughput mass spectrometry (MS)-based method that combines an injection of insulin with a non-radiolabeled glucose tracer, 2-fluoro-2-deoxyglucose (2FDG), to determine insulin-stimulated tissue-specific glucose clearance in conscious, unrestrained mice. Methods Injections of saline or insulin with 2FDG were coupled with LC-Q Exactive Hybrid Quadrupole-Orbitrap (LC) MS-based measures of plasma 2FDG and tissue (2-fluoro-2-deoxyglucose-6-phosphate) 2FDGP to determine glucose clearance in mice under several different conditions. Results The newly developed method was first applied to a dose response experiment in mice. Next, the ability of this method to quantify changes in glucose clearance in response to an insulin stimulus was assessed, and glucose clearance was compared between chow and high fat fed mice. Results from these studies showed that insulin-stimulated skeletal muscle and heart glucose clearance can be estimated following a bolus injection of tracer, and these fluxes are blunted in diet-induced obese mice. The broad applicability of this approach was then demonstrated by assessing glucose clearance in a mouse model with anticipated changes in insulin-stimulated skeletal muscle glucose metabolism. Conclusions The results validated a new LC-MS method to quantify insulin-stimulated tissue-specific glucose clearance in vivo without the use of catheters or radiolabeled tracers. The method offers great potential because it is designed for application to pre-clinical studies seeking high throughput tests and/or assays that can be coupled with discovery technologies such as genomics, proteomics and metabolomics. HIGHLIGHTS In vivo glucose clearance can be estimated by a new non-radiolabeled method. The plasma tracer to tracee ratio is required to determine tissue tracer phosphorylation. Measures of plasma glucose and tracer kinetics are critical for data interpretation. The new method can be combined with ‘omics’ technologies such as metabolomics.
Full text 2,275 characters · extracted from oa-doi-fallback · 4 sections · click to expand

Abstract

Objective A catheter-free, non-radiolabeled method that permits in vivo measurement of tissue-specific glucose uptake does not exist. To address this gap, we sought to develop and validate a new, higher throughput mass spectrometry (MS)-based method that combines an injection of insulin with a non-radiolabeled glucose tracer, 2-fluoro-2-deoxyglucose (2FDG), to determine insulin-stimulated tissue-specific glucose clearance in conscious, unrestrained mice.

Methods

Injections of saline or insulin with 2FDG were coupled with LC-Q Exactive Hybrid Quadrupole-Orbitrap (LC) MS-based measures of plasma 2FDG and tissue (2-fluoro-2-deoxyglucose-6-phosphate) 2FDGP to determine glucose clearance in mice under several different conditions.

Results

The newly developed method was first applied to a dose response experiment in mice. Next, the ability of this method to quantify changes in glucose clearance in response to an insulin stimulus was assessed, and glucose clearance was compared between chow and high fat fed mice. Results from these studies showed that insulin-stimulated skeletal muscle and heart glucose clearance can be estimated following a bolus injection of tracer, and these fluxes are blunted in diet-induced obese mice. The broad applicability of this approach was then demonstrated by assessing glucose clearance in a mouse model with anticipated changes in insulin-stimulated skeletal muscle glucose metabolism.

Conclusions

The results validated a new LC-MS method to quantify insulin-stimulated tissue-specific glucose clearance in vivo without the use of catheters or radiolabeled tracers. The method offers great potential because it is designed for application to pre-clinical studies seeking high throughput tests and/or assays that can be coupled with discovery technologies such as genomics, proteomics and metabolomics. HIGHLIGHTS In vivo glucose clearance can be estimated by a new non-radiolabeled method. The plasma tracer to tracee ratio is required to determine tissue tracer phosphorylation. Measures of plasma glucose and tracer kinetics are critical for data interpretation. The new method can be combined with ‘omics’ technologies such as metabolomics. Competing Interest Statement The authors have declared no competing interest.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00