Comparison of a custom Photogrammetry for Anatomical CarE (PHACE) system with other Low- Cost Facial Scanning Devices

preprint OA: closed
📄 Open PDF View at publisher

Abstract

Purpose To compare a custom Photogrammetry for Anatomical CarE (PHACE) system with other cost-effective 3-dimensional (3D) facial scanning systems to objectively characterize morphology and volume of periorbital and adnexal anatomy. Methods The imaging systems evaluated include the low-cost custom PHACE system and commercial software product for the iPhone called Scandy Pro (iScandy) application (Scandy, USA), and the mid-priced Einscan Pro 2X (Shining3D Technologies, China) device and Array of Reconstructed Cameras 7 (ARC7) facial scanner (Bellus3D, USA). Imaging was performed on a manikin facemask and humans with various Fitzpatrick scores. Scanner attributes were assessed using mesh density, reproducibility, surface deviation, and emulation of 3D printed phantom lesions affixed above the superciliary arch (brow line). Results The Einscan served as a reference for lower cost imaging systems because it qualitatively and quantitatively renders facial morphology with the highest mesh density, reproducibility (0.13 ± 0.10 mm), and volume recapitulation (approximately 2% of 33.5 μL). Compared to the Einscan, the PHACE system (0.35 ± 0.03 mm, 0.33 ± 0.16 mm) demonstrated non-inferior mean accuracy and reproducibility root mean square (RMS) compared to the iScandy (0.42 ± 0.13 mm, 0.58 ± 0.09 mm), and significantly more expensive ARC7 (0.42 ± 0.03 mm, 0.26 ± 0.09 mm). Similarly, the PHACE system showed non-inferior volumetric modeling when rendering a 124 μL phantom lesion compared to the iScandy and more costly ARC7 (mean percent difference from the Einscan: 4.68 ± 3.73%, 9.09 ± 0.94%, and 21.99 ± 17.91% respectively). Conclusions The affordable PHACE system accurately measures periorbital soft tissue as well as other established mid-cost facial scanning systems. Additionally, the portability, affordability, and adaptability of PHACE can facilitate widespread adoption of 3D facial anthropometric technology as an objective measurement tool in ophthalmology. Precis We demonstrate a custom system for facial photogrammetry (Photogrammetry for Anatomical CarE -PHACE) to produce 3D renderings of facial volume and morphology which compares with more expensive alternative 3D scanning technologies.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00