Surface Resistivity of Silicone Rubber Formulations Tested in Room Ambient Conditions: The Case of Silicone Rubber Formulations With and Without Filler Materials
preprint
OA: closed
Abstract
Silicone rubber formulations in the form of thin discs have been studied under room ambient conditions for their surface characteristics. The samples were silicone rubber manufactured in laboratory and those industrially manufactured. The measurements were done using an electrometer high resistance meter, applying dc voltage under normal room ambient conditions. The results show that the silicone rubber samples show higher values of surface resistivity when the dc voltage was applied. Silicone rubber samples manufactured in laboratory seem to exhibit erratic behaviour unlike their corresponding silicone rubbers manufactured in industry; this could be due to manufacturing shortcomings in laboratory and the irregularities in the way the silicone rubber adhered to the concentric ring electrodes. The empirical current traversing the surface of the silicone rubbers does not decay exponentially but rather it decays as an exponential power of the energization time.