A Three-Dimensional Visualization of the Full-Field Surgical Region Based on Thin-Slice MRI: an Elegant Approach for Simultaneously Guiding Tumor Resection and Perforator Flap Elevation.

preprint OA: closed
View at publisher

Abstract

Background: The goal of the current study was to explore the application of preoperative three-dimensional reconstruction (3DR) based on thin-slice magnetic resonance imaging (MRI) in the simultaneous guidance of tumor en bloc resection and adjacent perforator flap elevation. Methods: : The prospective cohort included 35 patients diagnosed with either soft tissue sarcoma or squamous cell skin cancer between 2019 and 2021. The preoperative 3DR based on thin-slice MRI illustrated the spatial anatomical relationship among the tumor, underlying muscle, adjacent perforator vessels, and bone around the surgical region. The accuracy of preoperative imaging data was verified by intraoperative vessel dissection and postoperative pathological measurements. Results: : Tumor size from 3DR data showed relatively high concordance rates with pathological measurements within the 95 % limits of agreement. An average of 3 perforators (range: 1, 7) with a mean diameter of 0.32 cm (range: 0.18, 0.74 cm) from the 3DR were present in our study. The average distance between tumor boundary and perforator piercing sites on the 3DR was 2.2 cm (range: 1.2, 7.7 cm). The average length of artery perforator coursing along the subcutaneous tissue was 5.8 cm (range: 3.3, 25.1 cm). The mean flap harvest time was 55 minutes (range: 36, 97 min). The average flap size was 92.2 cm 2 (range:32-126 cm 2 ). 1 perforator flap occurred distal partial necrosis. Conclusion: A thorough understanding of anatomical structures in the surgical region according to full-field 3DR based on thin-slice MRI can improve the performance of tumor radical resection and adjacent perforator flap transfer, especially for junior surgeons with poor experience. Trial registration: Chinese Clinical Trial Registry, ChiCTR2100050174. Registered 18 August 2021-retrospectively registered, https://www.chictr.org.cn/ ChiCTR2100050174

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00