Variable Power Functional Dilution Adjustment of Spot Urine
preprint
OA: closed
Abstract
Spot-urinary biomarkers are essential for medical, epidemiological, and environmental research. However, they are affected by hydration-dependent diuresis, requiring precise dilution adjustments. Traditional methods, like conventional creatinine correction (CCRC), have limitations and introduce errors due to residual diuresis dependence. To address this, the WHO recommends a valid creatinine (CRN) range of 0.3-3 g/L. The present study introduces a novel numerical variable power functional CRN correction method (V-PFCRC). It was developed using 5553 spot urinary samples for total weight arsenic from a diverse population with generally low background exposure to inorganic arsenic from drinking water. The innovative V-PFCRC formula normalizes analytes (A) to 1 g/L CRN using uncorrected analyte levels and two analyte-specific coefficients, c and d: A normalized = A uncorrected / CRN [c · Ln(A uncorrected) + d] / [c · Ln(CRN) + 1] When applied to spot urinary arsenic, iodine, cesium, molybdenum, strontium, and zinc, the V-PFCRC method significantly reduced residual CRN bias. It performed better compared to uncorrected, conventionally (CCRC), and simple power functionally CRN-corrected (S-PFCRC) urine samples. V-PFCRC enhanced CRN-bias removal in entire datasets and within seven separately analyzed analyte levels (septiles), adequately compensating for non-linear, exposure-differentiated skews, including complex metabolic and excretory interactions between analytes and CRN. These advancements were supported by improved blood-urine correlations for iodine and arsenic in both sexes, suggesting a more accurate representation of supply and exposure than traditional urinary dilution corrections. The results underscore the superior performance of the V-PFCRC method in adjusting for hydration-dependent variability, surpassing traditional correction methods. The resource-efficient and versatile V-PFCRC method is easy to implement and holds immense potential for broader applications in various scientific and medical fields. This study advocates for the wider adoption of V-PFCRC to enhance the accuracy and reliability of urinary biomarkers, ensuring superior diagnostic and research outcomes. Keywords: Non-linear dilution adjustment, variable power-functional dilution adjustment, creatinine correction, spot urine, biomarkers, arsenic, iodine, metal analytics, exposure studies.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00