Development of a UVGI System and Evaluation of Germicidal Potential Against Biofilm-Forming Bacteria and Fungi Under Controlled Laboratory Conditions

preprint OA: closed
View at publisher

Abstract

A compact, in-house developed ultraviolet germicidal irradiation (UVGI) system adaptable to static, mobile, or robotic platforms was developed for the effective sterilization of bacteria and fungi using a wireless mode of operation. Under controlled laboratory conditions, its efficacy was evaluated against three representative biofilm-forming pathogens: Bacillus subtilis (Gram-positive, spore-forming, motile bacterium), Escherichia coli K12 (Gram-negative, non-spore-forming, non-motile bacterium), and Candida albicans M-207 (multi-drug-resistant, clinical yeast isolate). Microbial viability following UVGI exposure was assessed using colony-forming unit (CFU) and MTT assays, and morphological alterations were characterized by scanning electron microscopy (SEM). Cultures were exposed to UV-C radiation at distances of 1–5 m for 15–90 min. CFU assay demonstrated 100% kill of all tested organisms at 1 m and 15 min, corresponding to doses of 600.3, 576 & 697.5 mJ/cm². Although MTT assays indicated residual metabolic activity under the same conditions, CFU results confirmed that surviving cells were unable to proliferate, highlighting the robustness of UV treatment for long-term inactivation. SEM confirmed distinct morphological alterations such as complete destruction of extracellular matrix & reduction in number of cells indicating cell death with increase in UV dose as compared to controls. A dose & time-dependent inactivation of biofilm-forming bacteria & fungi was observed on exposure to UVGI. Therefore, this pilot study validates the effectiveness of the newly developed UVGI surface sterilizer against biofilm-forming bacterial and fungal pathogens. Overall, the system demonstrates proof-of-concept efficacy under laboratory conditions and holds strong potential for future development and validation in hospitals and other contaminated public spaces. Graphical Abstract IMPORTANCE Microorganisms that form biofilms on surfaces are difficult to eliminate and contribute to the spread of infections in healthcare and indoor environments. There is a need for practical, easy-to-use disinfection technologies that can effectively reduce such contamination. In this study, we developed a compact, in-house, wireless UV-C disinfection system designed for flexible operation across different surface types. The system was evaluated under controlled laboratory conditions using representative biofilm-forming bacterial and fungal pathogens. Our findings show that the system can effectively reduce microbial contamination, demonstrating proof-of-concept efficacy. This work highlights the potential of accessible, non-chemical UV-based technologies and supports their further validation for applications in real-world disinfection settings.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00