Minimising Radiation Exposure in Catheter Ablation of Ventricu-lar Arrhythmias
preprint
OA: closed
Abstract
Background: Conventional fluoroscopy (CF) guided catheter ablation (CA) is an established treatment option for ventricular arrhythmias (VAs). However, with the complex nature of most procedures, patients and staff bare an increased radiation exposure. Near-zero or zero-fluoroscopy CA is an alternative method which could substantially reduce or even eliminate the radiation dose. Our aim was to analyse procedural outcomes with fluoroscopy minimising approach for treatment of VAs in patients with structurally normal hearts (SNH) and structural heart disease (SHD). Methods: Fifty-two (age 53.4±17.8 years, 38 male, 14 female) consecutive patients who underwent CA of VAs in our institution between May 2018 and December 2019 were included. Procedures were performed primarily with the aid of the three-dimensional (3D) electro-anatomical mapping (EAM) system and intra-cardiac echocardiography (ICE). Fluoroscopy was considered only in left ventricular (LV) summit mapping for coronary angiography and when epicardial approach was planned. Acute and long-term procedural outcomes were analysed. Results: Sixty CA procedures were performed. Twenty-five patients had SHD-related VAs (Group 1) and 27 patients had SNH (Group 2). While Group 1 had significantly higher total procedural time (256.9±71.7 vs 123.6±42.2 minutes; p < 0.001) compared to Group 2, overall procedural success rate [77.4% (24/31) vs 89.7% (26/29); p= 0.20)] and recurrence rate after the first procedure [8/25, (32%) vs 8/27, (29.6%); p= 0.85] were similar in both groups. Fluoroscopy was used in 3 procedures in Group 1 where epicardial approach was needed and in 4 procedures in Group 2 where LV summit VAs were ablated. Overall procedure-related major complications were low (3/60, 5%). Conclusions: Fluoroscopy minimising approach for CA of VAs is feasible and safe in patients with SHD and SNH. Fluoroscopy could not be completely abolished in VAs with epicardial and LV summit substrate location.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00