PURPOSE: Endometriosis is a benign, but potentially serious gynaecological condition in terms of abdominal pain and impaired fertility. Laparoscopic excision techniques are considered the therapeutic standard. HybridAPC is presented as a novel technique for the non-contact thermal ablation of peritoneal endometriosis with simultaneous protection of the underlying thermosensitive structures by creating a needle-free elevated fluid cushion which enables a safer exposure and distance, as well as potentially improved peritoneal conditioning prior to APC.
METHODS: In this prospective randomized clinical trial, 39 patients with 132 superficial endometriotic lesions in total were treated with HybridAPC or sharp excision in an initial laparoscopic procedure according to randomization. In a second-look laparoscopy, adhesion formation was rated macroscopically. Histologic samples were taken from previously treated areas for evaluation of eradication rate.
RESULTS: The eradication rate was not significantly different between HybridAPC treatment and sharp excision (65 vs. 81%, p = .55). Adhesions formed in 5% of HybridAPC-treated lesions and in 10% after sharp excision (p = .49). HybridAPC treatment was significantly faster than sharp excision (69 vs. 106 s, p < .05). No intra- and postoperative complications were registered.
CONCLUSION: This clinical trial demonstrates the feasibility of this novel surgical technique with a promising impact on adhesion prevention. Compared to sharp excision, HybridAPC is likely to be a safe, tissue-preserving, and fast method for the treatment of peritoneal endometriosis.
My notes (saved in your browser only)
Condition tags
MeSH descriptors
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-06-24T06:10:11.469335+00:00
- pubmed
- last seen: 2026-05-17T00:34:43.299282+00:00
- unpaywall
- last seen: 2026-05-14T19:30:52.867331+00:00
License: CC-BY-4.0
· commercial use OK
· attribution required
Courtesy of the U.S. National Library of Medicine
Courtesy of the U.S. National Library of Medicine