Elastography Improves the Accuracy of Ultrasound in the Preoperative Assessment of abdominal wall endometriosis

article OA: closed CC0 ⤵ 10 in-corpus citations
View on OpenAlex View on PubMed View at publisher
AI-generated summary by claude@2026-06, 2026-06-06

Elastography significantly improved the accuracy of ultrasound in assessing abdominal wall endometriosis depth, unaffected by BMI, compared to B-mode alone.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

AI-generated deep summary by claude@2026-06, 2026-06-06

This study evaluated whether ultrasound elastography improves the preoperative localization of abdominal wall endometriosis (AWE) compared with B-mode ultrasound alone in 33 patients scheduled for surgical excision. Using transabdominal ultrasound with an added elastography (alpha-blend) option, lesions were categorized by depth (superficial/intermediate/deep) and findings were verified intraoperatively; surgeons were blinded to elastography results, and the influence of obesity was assessed. B-mode alone correctly located AWE in 33.3% of cases, whereas adding elastography increased accuracy to 87.9% (p < 0.05), with decreased ultrasound accuracy in overweight/obese patients that was not seen when elastography was added. This paper is centrally about endometriosis — it focuses on elastography improving the preoperative ultrasound assessment of abdominal wall endometriosis infiltration depth.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Abstract

PURPOSE: To assess the role of elastography in preoperative ultrasound assessment of abdominal wall endometriosis (AWE) location. MATERIALS AND METHODS: 33 patients qualified for surgical excision of AWE were included in the study. Preoperative assessment of AWE was performed transabdominally on a Samsung Medison V20 Prestige with a transvaginal probe and Elastoscan® option. The following B-mode settings were used: focus set to the lower end of the lesion, gain adjusted to obtain best image quality, tissue harmonic imaging activated. For elastographic examinations the color map from red (soft) to purple (hard) and the alpha blend option (a blend of B-mode and elastographic image) were used. AWE location was first assessed by B-mode ultrasound as: superficial (located in SCT only; SCT visible between the fascia and the lesion; intact fascia), intermediate (located in SCT or in RAM; no subcutaneous or muscle tissue between the lesion and the fascia; fascia infiltrated); or deep (located in RAM; muscle tissue visible between the lesion and the fascia; fascia intact). Then the AWE location was assessed by alphablend elastography as: superficial (hard lesion in soft SCT; soft SCT between the fascia and the lesion; no hard areas on the fascia); intermediate (hard lesion in soft SCT or soft RAM; no soft subcutaneous or muscle tissue between the lesion and the fascia; hard areas on the fascia); or deep (hard lesion located in RAM; soft muscle tissue between the fascia and the lesion; no hard areas on the fascia). These findings were verified during surgery. The surgeons were blinded to the results of elastography. The influence of obesity on the accuracy of ultrasound and elastography in assessing the location of AWE was evaluated. RESULTS: During surgery superficial AWE was found in 6, intermediate in 19 and deep in 8 patients. Preoperative ultrasound assessment was correct in 33.3 % of cases, while adding the elastography option improved the accuracy of AWE location assessment to 87.9 % (p < 0.05). The diagnostic accuracy of ultrasound alone, but not with the elastography option, was significantly decreased in the preoperative assessment of AWE location in overweight and obese patients. 4 patients required implantation of a mesh. In all cases the pathological examination confirmed the diagnosis of AWE. CONCLUSION: Elastography significantly improved the accuracy of ultrasound in evaluating the depth of infiltration of AWE, is not affected by increased BMI, and should be considered in patients qualified for surgical treatment of AWE.

My notes (saved in your browser only)

Condition tags

endometriosis

MeSH descriptors

Abdominal Wall Elasticity Imaging Techniques Endometriosis Endosonography Ultrasonography Abdominal Wall Abdominal Wall Adult Cesarean Section Elasticity Imaging Techniques Elasticity Imaging Techniques Endometriosis Endometriosis Endosonography Endosonography Female Humans Postoperative Complications Postoperative Complications Postoperative Complications

Citation neighborhood

Papers in the corpus that this work cites (lower rings, blue) and that cite this one (upper rings, green). Dot size scales with the paper's in-corpus citation count — bigger dot = more influential within the endo/adeno field. Click a dot to open that paper. [ expand to 2 hops ] — adds papers reached through this work's immediate citers/citees. Heavier; up to 60 extra dots.

Cited by (10)

Source provenance

europepmc
last seen: 2026-06-12T06:13:51.797165+00:00
openalex
last seen: 2026-06-10T17:14:06.276822+00:00
pubmed
last seen: 2026-05-13T22:17:58.238279+00:00
License: CC0 · commercial use OK