Evaluating the reliability of emergency control equipment based on the Weibull distribution

preprint OA: closed
Full text JSON View at publisher
AI-generated summary by claude@2026-07, 2026-07-14

This study used a modified three-parameter Weibull distribution and accelerated life testing to evaluate the reliability of mine safety power cylinders and solenoid valves, improving accuracy by 14.9% over traditional methods.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

AI-generated deep summary by claude@2026-07, 2026-07-14 · read from full text

This preprint studied how to evaluate the reliability and service-life characteristics of mine emergency control equipment, specifically a power cylinder and a pneumatic solenoid valve, using three-parameter Weibull distribution modeling combined with accelerated life testing. Using experimental test data and a modified three-parameter Weibull approach, the authors assessed service-life characteristics across time and environmental stressors including temperature, humidity, and dust concentration, and built a MATLAB interface for monitoring equipment data and reliability outputs. They report that their reliability evaluation system reduced calculation error by 14.9% compared with traditional reliability calculation factors and improved the fit between the modeled reliability function and observed reliability change curves, enabling real-time reliability evaluation. A major caveat explicitly stated is that the work is a preprint and has not been peer reviewed. The paper does not explicitly discuss endometriosis or adenomyosis; it was included in the corpus via a keyword match in the upstream search index.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Abstract

Abstract The safety and emergency control equipment in mines often lack effective monitoring. Based on the three-parameter Weibull distribution function, combined with the principle of accelerated life tests, this study analyzes the equipment service life characteristics of the power cylinder and pneumatic solenoid valve found in mine safety systems. Experimental test data are obtained and the service life characteristics are determined with respect to time, temperature, humidity, and dust concentration through a modified three-parameter Weibull distribution function. A display interface for monitoring the equipment data and reliability results is established using Matlab, and the reliability of emergency control equipment is evaluated. The results show that the proposed reliability evaluation system overcomes the shortcomings of traditional reliability calculation factors such as temperature and humidity, and reduces the calculation error by 14.9%. The proposed approach improves the fitting degree between the reliability function and the actual reliability change curve, and enables real-time reliability evaluations of emergency control equipment.
Full text 10,201 characters · extracted from preprint-html · click to expand
Evaluating the reliability of emergency control equipment based on the Weibull distribution | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Article Evaluating the reliability of emergency control equipment based on the Weibull distribution Jiayong ZHANG, Liwen GUO, Peiyang SU, Jia JIA This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-1476973/v1 This work is licensed under a CC BY 4.0 License Status: Posted Version 1 posted You are reading this latest preprint version Abstract The safety and emergency control equipment in mines often lack effective monitoring. Based on the three-parameter Weibull distribution function, combined with the principle of accelerated life tests, this study analyzes the equipment service life characteristics of the power cylinder and pneumatic solenoid valve found in mine safety systems. Experimental test data are obtained and the service life characteristics are determined with respect to time, temperature, humidity, and dust concentration through a modified three-parameter Weibull distribution function. A display interface for monitoring the equipment data and reliability results is established using Matlab, and the reliability of emergency control equipment is evaluated. The results show that the proposed reliability evaluation system overcomes the shortcomings of traditional reliability calculation factors such as temperature and humidity, and reduces the calculation error by 14.9%. The proposed approach improves the fitting degree between the reliability function and the actual reliability change curve, and enables real-time reliability evaluations of emergency control equipment. Full Text Additional Declarations No competing interests reported. Cite Share Download PDF Status: Posted Version 1 posted You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-1476973","acceptedTermsAndConditions":true,"allowDirectSubmit":true,"archivedVersions":[],"articleType":"Article","associatedPublications":[],"authors":[{"id":95254648,"identity":"89177ff9-dd46-4de4-8624-7455ab5fa75e","order_by":0,"name":"Jiayong ZHANG","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAvElEQVRIiWNgGAWjYHCCxAeJf2x4+PkbiNeSbPCwIU1GcsYB4rWwST5sOGxj0JBApHr5GQmPDRJ3nOcxYDjA+OFjDhFaGGckAP1y5jaPOXMDs+TMbURoYZZISDZIYLvNY9lwgI2ZlxgtbBIJaRIJbOd4DA4kEKmFB6Qlse0ACVokeB4AHXYmmUdyxsFm4vwi356T+PBHhZ09P3/zwQ8fidHCIJCTAGUxNhCjHgj4jx8gUuUoGAWjYBSMWAAAY784T/86XQgAAAAASUVORK5CYII=","orcid":"","institution":"North China University of Science and Technology","correspondingAuthor":true,"prefix":"","firstName":"Jiayong","middleName":"","lastName":"ZHANG","suffix":""},{"id":95254644,"identity":"99914ffe-846c-4aa7-a757-a0687229dd22","order_by":1,"name":"Liwen GUO","email":"","orcid":"","institution":"North China University of Science and Technology","correspondingAuthor":false,"prefix":"","firstName":"Liwen","middleName":"","lastName":"GUO","suffix":""},{"id":95254645,"identity":"2ed5370b-854e-4cff-97d8-cc0a40df52a1","order_by":2,"name":"Peiyang SU","email":"","orcid":"","institution":"North China University of Science and Technology","correspondingAuthor":false,"prefix":"","firstName":"Peiyang","middleName":"","lastName":"SU","suffix":""},{"id":95254650,"identity":"f66df00a-a376-4485-bfdd-956fd4494989","order_by":3,"name":"Jia JIA","email":"","orcid":"","institution":"North China University of Science and Technology","correspondingAuthor":false,"prefix":"","firstName":"Jia","middleName":"","lastName":"JIA","suffix":""}],"badges":[],"createdAt":"2022-03-22 09:29:09","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-1476973/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-1476973/v1","draftVersion":[],"editorialEvents":[],"editorialNote":"","failedWorkflow":false,"files":[{"id":19951427,"identity":"58d88367-dbda-4f3b-b50f-fe7c6edbb28c","added_by":"auto","created_at":"2022-04-04 20:22:57","extension":"pdf","order_by":1,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":662143,"visible":true,"origin":"","legend":"","description":"","filename":"EvaluatingthereliabilityofemergencycontrolequipmentbasedontheWeibulldistribution.pdf","url":"https://assets-eu.researchsquare.com/files/rs-1476973/v1_covered.pdf"}],"financialInterests":"No competing interests reported.","formattedTitle":"Evaluating the reliability of emergency control equipment based on the Weibull distribution","fulltext":[{"header":"Full Text","content":"This preprint is available for \u003ca href='/article/rs-1476973/latest.pdf' target='_blank'\u003edownload as a PDF\u003c/a\u003e."}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":false,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":true,"highlight":"","institution":"","isAcceptedByJournal":false,"isAuthorSuppliedPdf":true,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"[email protected]","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true},"keywords":"","lastPublishedDoi":"10.21203/rs.3.rs-1476973/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-1476973/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"The safety and emergency control equipment in mines often lack effective monitoring. Based on the three-parameter Weibull distribution function, combined with the principle of accelerated life tests, this study analyzes the equipment service life characteristics of the power cylinder and pneumatic solenoid valve found in mine safety systems. Experimental test data are obtained and the service life characteristics are determined with respect to time, temperature, humidity, and dust concentration through a modified three-parameter Weibull distribution function. A display interface for monitoring the equipment data and reliability results is established using Matlab, and the reliability of emergency control equipment is evaluated. The results show that the proposed reliability evaluation system overcomes the shortcomings of traditional reliability calculation factors such as temperature and humidity, and reduces the calculation error by 14.9%. The proposed approach improves the fitting degree between the reliability function and the actual reliability change curve, and enables real-time reliability evaluations of emergency control equipment.","manuscriptTitle":"Evaluating the reliability of emergency control equipment based on the Weibull distribution","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2022-04-04 20:22:51","doi":"10.21203/rs.3.rs-1476973/v1","editorialEvents":[{"type":"communityComments","content":0}],"status":"published","journal":{"display":true,"email":"[email protected]","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"7dd91885-fc51-4f96-8267-790882bbe236","owner":[],"postedDate":"April 4th, 2022","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"posted","subjectAreas":[],"tags":[],"updatedAt":"2022-05-26T05:44:10+00:00","versionOfRecord":[],"versionCreatedAt":"2022-04-04 20:22:51","video":"","vorDoi":"","vorDoiUrl":"","workflowStages":[]},"version":"v1","identity":"rs-1476973","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-1476973","identity":"rs-1476973","version":["v1"]},"buildId":"_2-kVJe1T_tPrBINL-cwx","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00