The study develops an adaptive spatio-temporal phase retrieval approach (the STAR algorithm) for actively shaping ultra-short, single-cycle ultrasound pulses, aiming to improve multi-line transmission and other single-cycle holography/structured illumination tasks that rely on precise time-domain control. Using an iterative optimization scheme that incorporates the generalized angular spectrum method and enforces constraints at both the transducer and focal planes, simulations found STAR outperformed the Gerchberg–Saxton algorithm for multi-focus patterns, including higher correlation (0.80 vs 0.64), better uniformity, and smaller minimum distinguishable focal spacing (0.87 mm vs 1.09 mm); hydrophone experiments supported these findings. A stated caveat is that the focus is on beam shaping performance for diagnostic ultrasound use cases rather than broader biological validation. This paper does not explicitly discuss endometriosis or adenomyosis; it was included in the corpus via a keyword match in the upstream search index.
Abstract
Beam shaping of ultra-short pulses is essential for medical ultrasound, where single-cycle excitations are required to achieve high axial resolution and improve frame rate. Conventional methods, such as the Gerchberg–Saxton (GS) algorithm or more recent deep learning approaches, are generally effective for continuous-wave excitation but degrade significantly under single-cycle conditions. In diagnostic imaging, high frame rate is critical for applications demanding rapid scanning. In this context, multi-line transmission (MLT) leverages beam shaping to synthesize multiple simultaneous foci, thereby increasing frame rate. In parallel, structured illumination methods for super-resolution and acoustical holography likewise depend on actively shaping single-cycle pulses to produce controlled patterns, highlighting the need for precise short-pulse beam shaping. To address this challenge, we introduce the spatio-temporal adaptive reconstruction (STAR) algorithm, which performs active beam shaping directly in the time domain by integrating the generalized angular spectrum method (GASM) into an iterative optimization scheme. STAR enforces constraints on both the transducer and focal planes, enabling accurate control of single-cycle excitations. Simulations showed that STAR consistently outperformed GS for multi-focus patterns. For example, in a four-foci configuration, STAR achieved a correlation of 0.80 compared to 0.64 for GS, with significantly improved uniformity across focal peaks. Resolution analysis demonstrated that STAR reduced the minimum distinguishable foci spacing from 1.09 mm with GS to 0.87 mm. Experimental hydrophone measurements confirmed these improvements. Across multi-foci patterns, STAR produced more distinct and balanced foci compared to those observed with GS. These results demonstrate that STAR provides robust and efficient active beam shaping of single-cycle pulses, maintaining accuracy across different depths and frequencies for diagnostic applications.
Full text
2,518 characters
· extracted from
oa-doi-fallback
· click to expand
Abstract
Beam shaping of ultra-short pulses is essential for medical ultrasound, where single-cycle excitations are required to achieve high axial resolution and improve frame rate. Conventional methods, such as the Gerchberg–Saxton (GS) algorithm or more recent deep learning approaches, are generally effective for continuous-wave excitation but degrade significantly under single-cycle conditions. In diagnostic imaging, high frame rate is critical for applications demanding rapid scanning. In this context, multi-line transmission (MLT) leverages beam shaping to synthesize multiple simultaneous foci, thereby increasing frame rate. In parallel, structured illumination methods for super-resolution and acoustical holography likewise depend on actively shaping single-cycle pulses to produce controlled patterns, highlighting the need for precise short-pulse beam shaping. To address this challenge, we introduce the spatio-temporal adaptive reconstruction (STAR) algorithm, which performs active beam shaping directly in the time domain by integrating the generalized angular spectrum method (GASM) into an iterative optimization scheme. STAR enforces constraints on both the transducer and focal planes, enabling accurate control of single-cycle excitations. Simulations showed that STAR consistently outperformed GS for multi-focus patterns. For example, in a four-foci configuration, STAR achieved a correlation of 0.80 compared to 0.64 for GS, with significantly improved uniformity across focal peaks. Resolution analysis demonstrated that STAR reduced the minimum distinguishable foci spacing from 1.09 mm with GS to 0.87 mm. Experimental hydrophone measurements confirmed these improvements. Across multi-foci patterns, STAR produced more distinct and balanced foci compared to those observed with GS. These results demonstrate that STAR provides robust and efficient active beam shaping of single-cycle pulses, maintaining accuracy across different depths and frequencies for diagnostic applications.
Competing Interest Statement
The authors have declared no competing interest.
Footnotes
This work was supported in part by the Israel Science Foundation under Grant 192/22, in part by the Israel Ministry of Scienc e and Technology under Grant 101716, in part by an ERC StG under Grant 101041118 (NanoBubbleBrain), the Israel Cancer Research Fund (grant number 1286686), and in part by the Nicholas and Elizabeth Slezak Super Center for Cardiac Research and Biomedical Engineering at Tel Aviv University.
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.