Automated assessment of chest CT severity scores in patients suspected of COVID-19 infection

preprint OA: closed
📄 Open PDF View at publisher
AI-generated summary by claude@2026-07, 2026-07-17

A deep learning model automatically assessed COVID-19 CT severity scores with an MAE lower than radiologists and comparable sensitivity and specificity.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

ABSTRACT Background The COVID-19 pandemic has claimed numerous lives in the last three years. With new variants emerging every now and then, the world is still battling with the management of COVID-19. Purpose To utilize a deep learning model for the automatic detection of severity scores from chest CT scans of COVID-19 patients and compare its diagnostic performance with experienced human readers. Methods A deep learning model capable of identifying consolidations and ground-glass opacities from the chest CT images of COVID-19 patients was used to provide CT severity scores on a 25-point scale for definitive pathogen diagnosis. The model was tested on a dataset of 469 confirmed COVID-19 cases from a tertiary care hospital. The quantitative diagnostic performance of the model was compared with three experienced human readers. Results The test dataset consisted of 469 CT scans from 292 male (average age: 52.30 ± 15.90 years) and 177 female (average age: 53.47 ± 15.24) patients. The standalone model had an MAE of 3.192, which was lower than the average radiologists’ MAE of 3.471. The model achieved a precision of 0.69 [0.65, 0.74] and an F1 score of 0.67 [0.62, 0.71], which was significantly superior to the average reader precision of 0.68 [0.65, 0.71] and F1 score of 0.65 [0.63, 0.67]. The model demonstrated a sensitivity of 0.69 [95% CI: 0.65, 0.73] and specificity of 0.83 [95% CI: 0.81, 0.85], which was comparable to the performance of the three human readers, who had an average sensitivity of 0.71 [95% CI: 0.69, 0.73] and specificity of 0.84 [95% CI: 0.83, 0.85]. Conclusion The AI model provided explainable results and performed at par with human readers in calculating CT severity scores from the chest CT scans of patients affected with COVID-19. The model had a lower MAE than that of the radiologists, indicating that the CTSS calculated by the AI was very close in absolute value to the CTSS determined by the reference standard.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00