Sequentially-reduced representation of artificial neural network to determine cardiovascular intrinsic frequencies
preprint
OA: closed
Abstract
Analysis of cardiovascular waveforms provides valuable clinical information about the state of health and disease. The intrinsic frequency (IF) method is a recently introduced framework that uses a single arterial pressure waveform to extract physiologically relevant information about the cardiovascular system. The clinical usefulness and physiological accuracy of the IF method have been well-established via several preclinical and clinical studies. However, the computational complexity of the current L 2 optimization solver for IF calculations remains a bottleneck for practical deployment of the IF method in real-time settings. In this paper, we propose a machine learning (ML)-based methodology for determination of IF parameters from a single carotid waveform. We use a sequentially-reduced Feedforward Neural Network (FNN) model for mapping carotid waveforms to the output parameters of the IF method, thereby avoiding the non-convex L 2 minimization problem arising from the conventional IF approach. Our methodology also includes procedures for data pre-processing, model training, and model evaluation. In our model development, we used both clinical and synthetic waveforms. Our clinical database is composed of carotid waveforms from two different sources: the Huntington Medical Research Institutes (HMRI) iPhone Heart Study and the Framingham Heart Study (FHS). In the HMRI and FHS clinical studies, various device platforms such as piezoelectric tonometry, optical tonometry (Vivio), and an iPhone camera were used to measure arterial waveforms. Our blind clinical test shows very strong correlations between IF parameters computed from the FNN-based method and those computed from the standard L 2 optimization-based method (i.e., R≥0.93 and P-value ≤0.005 for each IF parameter). Our results also demonstrate that the performance of the FNN-based IF model introduced in this work is independent of measurement apparatus and of device sampling rate.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00