Comparison of Four Real-time Polymerase Chain Reaction Assays for the Detection of SARS-CoV-2 on respiratory samples from Tunja, Boyacá - Colombia

preprint OA: gold CC-BY-4.0
🔓 Open OA copy View at publisher

Abstract

Background: Coronavirus disease (COVID-19) is an infectious disease caused by the SARS-CoV-2. In Colombia, many commercial methods are now available to perform the RT-qPCR assays, and the laboratories must evaluate its diagnostic accuracy to ensure reliable results to suspected COVID-19 patients. The purpose of the study was to compare four commercial RT-qPCR assays for detection of SARS-CoV2 virus, from nasopharyngeal swab samples referred to Laboratorio Carvajal IPS, SAS of Tunja, Boyacá - Colombia. Methods: This prospective study was conducted on 152 samples of respiratory tract samples (Nasopharyngeal Swab) from patients with suspected SARS-CoV-2 infection. Diagnostic accuracy of GeneFinderTM COVID-19 Plus RealAmp (In Vitro diagnostic), One-Step Real-Time RT-PCR (Vitro Master diagnostica), Berlin modified protocol and gold standard Berlin protocol (Berlin Charite Probe One-Step RT-qPCR Kit, New England Biolabs) as reference was assessed. Operational characteristics were estimated in terms of sensitivity, specificity, agreement, and predictive values. Results: Using Berlin Charite Probe One-Step RT-qPCR Kit as reference, the sensitivity/specificity for the diagnostic tests were found to be GeneFinderTM COVID-19 Plus RealAmp Kit 100%/92.7%, One-Step Real-Time RT-PCR, One-Step Real-Time RT-PCR 92.75%/67.47%, and Berlin modified protocol 100%/96.39%. The results of four commercially available methods were found to be consistent with those obtained from Berlin Modified protocol analysis for % of the samples and showed good agreement (κ= 0.96). Concordant SARS-CoV2 negative and positive RT-qPCR results were reported for xxx and xxx samples, respectively. Summarize something about the Ct. Conclusion: Our data demonstrate that all commercially available methods are rapid and reliable for the identification of SARS-CoV-2 virus associated with COVID-19. One-Step RT-qPCR Kit and GeneFinderTM COVID-19 Plus RealAmp assay show optimal sensitivity compared with Belin modified protocol. In addition, there is no significant correlation between xxxxx

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-21T05:10:58.409756+00:00
License: CC-BY-4.0