MRI-Based Blood Clot Phenotyping: An In Vitro Study

preprint OA: closed
Full text JSON View at publisher

Abstract

ABSTRACT Background and Purpose Neurointerventional outcomes depend on clot composition and may be influenced by clot contraction. Thus, a priori identification of clot composition and contraction could inform procedural strategies and improve outcomes. The goal of our work is to conduct an in vitro test to determine whether MRI can reliably predict both clot composition and contractile state. Materials and Methods To this end, we prepared blood clots spanning clinically observed compositions (0-80% red blood cells (RBCs)) in both contracted and uncontracted states. Contraction was controlled by coagulating blood with or without thrombin. We imaged these clots using quantitative, clinical, and investigational MRI sequences. Using these data, we then determined whether MRI signal intensities, quantitative parameters, and radiomic features capturing intensity and texture patterns can (i) predict clot hematocrit and (ii) classify clots by composition (RBC-rich vs. fibrin-rich) and contraction state. Results Quantitative MRI parameters (T1, T2, ADC) decreased with increasing hematocrit (R 2 = 0.56–0.85, p < 0.001), while signal intensities from clinical sequences showed weaker correlations (R 2 = 0.46–0.62, p < 0.001). Radiomic models predicted hematocrit with performance comparable to MRI parameters. When applied to classification, radiomic features accurately discriminated RBC-versus fibrin-rich clots, with AUCs exceeding 0.90 across nearly all sequences. In contrast, classification of contraction state showed greater variability in AUCs across sequences but remained high for quantitative T1 and T2 values (AUCs up to 0.88). Trends were consistent across clots coagulated with and without thrombin. Pooling features across sequences did not outperform the best individual sequence for either regression or classification. Conclusions We demonstrate that MRI-based radiomic analysis quantitatively characterizes clot composition and contraction in vitro. These findings support the feasibility of using MRI for pre-interventional clot phenotyping, with potential to inform thrombolytic and mechanical thrombectomy strategies. Thus, in vivo studies validating these results are warranted.
Full text 2,287 characters · extracted from oa-doi-fallback · 4 sections · click to expand

Abstract

Background and Purpose Neurointerventional outcomes depend on clot composition and may be influenced by clot contraction. Thus, a priori identification of clot composition and contraction could inform procedural strategies and improve outcomes. The goal of our work is to conduct an in vitro test to determine whether MRI can reliably predict both clot composition and contractile state.

Materials and methods

To this end, we prepared blood clots spanning clinically observed compositions (0-80% red blood cells (RBCs)) in both contracted and uncontracted states. Contraction was controlled by coagulating blood with or without thrombin. We imaged these clots using quantitative, clinical, and investigational MRI sequences. Using these data, we then determined whether MRI signal intensities, quantitative parameters, and radiomic features capturing intensity and texture patterns can (i) predict clot hematocrit and (ii) classify clots by composition (RBC-rich vs. fibrin-rich) and contraction state.

Results

Quantitative MRI parameters (T1, T2, ADC) decreased with increasing hematocrit (R2 = 0.56–0.85, p < 0.001), while signal intensities from clinical sequences showed weaker correlations (R2 = 0.46–0.62, p < 0.001). Radiomic models predicted hematocrit with performance comparable to MRI parameters. When applied to classification, radiomic features accurately discriminated RBC-versus fibrin-rich clots, with AUCs exceeding 0.90 across nearly all sequences. In contrast, classification of contraction state showed greater variability in AUCs across sequences but remained high for quantitative T1 and T2 values (AUCs up to 0.88). Trends were consistent across clots coagulated with and without thrombin. Pooling features across sequences did not outperform the best individual sequence for either regression or classification.

Conclusions

We demonstrate that MRI-based radiomic analysis quantitatively characterizes clot composition and contraction in vitro. These findings support the feasibility of using MRI for pre-interventional clot phenotyping, with potential to inform thrombolytic and mechanical thrombectomy strategies. Thus, in vivo studies validating these results are warranted. Competing Interest Statement The authors have declared no competing interest.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00