Biodegradable Architected Stents for Endoscopic Internal Drainage

preprint OA: closed
Full text JSON View at publisher
Full text 1,446 characters · extracted from oa-doi-fallback · click to expand
Abstract Postoperative gastric leak after bariatric surgery is a serious complication associated with prolonged treatment, repeated interventions, and substantial morbidity. Endoscopic internal drainage using double pigtail stents is widely adopted. However, current stents, originally designed for biliary use and often based on simple cylindrical geometries, are not optimized for post-bariatric gastric leak anatomy, mechanical support, or fluid drainage. Here, we present BRIDGE (Biodegradable aRchitected Internal DrainaGE), a stent concept integrating triply periodic minimal surface (TPMS) architectures to control mechanical compliance, kink resistance, and drainage performance. Using computational modeling, mechanical testing, and benchtop flow studies, we evaluate TPMS designs and identify volume fraction as a key parameter balancing flexibility, structural integrity, and hydraulic performance. TPMS-integrated designs tolerated a 7.1-fold smaller bend radius than a commercial stent without kinking and achieved up to a 2-fold increase in drainage. We also developed a stereolithography-printable biodegradable resin and fabricated a prototype lattice-integrated stent. Teaser A biodegradable, 3D-printed stent with an architected lattice design improves flexibility, kink resistance, and abscess drainage while eliminating the need for device removal. Competing Interest Statement The authors have declared no competing interest.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00