Modified Blade: an Interventional Options in Rigid Bronchoscopy for Non-resectable Tracheal Stenosis

preprint OA: closed
View at publisher

Abstract

INTRODUCTION Benign tracheobronchial stenosis is a abnormal tracheal lumen narrowing that may incur progressive dyspnea and life-threatening hypoxemia. There is no consensus on which patients should be treated with endoscopic or surgical method. This study investigates the outcomes bronchoscopic dilatation for treating benign tracheal stenosis using a device equipped with a blade to cut the stenotic lesions with dense fibrosis. MATERIALS AND METHODS The procedure was carried out in an operating room under general anesthesia. All patients were intubated with a Rigid Bronchoscope (RB) placed just above the stenosis. Through Rigid Bronchoscopy combined modalities were used as needed: radial incisions of the mucosal stenosis with blade at the levels of 4, 8 and 12 o’clock, with back and forth movements, then the stenotic area was dilated more easily with a rigid bronchoscope. Dilatation was performed by passing the RB through stenotic areas of increasing diameter and then Balloon dilation of increasing diameter. There were no complications during the procedure. RESULT We conducted an observational, retrospective, single-centre study in the Thoracic Surgery Unit of the University of ‘Luigi Vanvitelli’ of Naples from November 2011 to December 2022. We included all consecutive patients with benign tracheal stenosis inoperable. During the study period, 113 patients were referred to our department with benign tracheal stenosis inoperable. 61 patients were treated with the blade. During the follow-up, a recurrence of the stenosis was observed in 8 patients in the first month and in 4 patients in the third month. Instead in the patients treated with the use of laser (59 patients), during the follow-up a recurrence was observed in 16 patients in the first month and in 6 patients in the third month; no patient relapsed after 6 months and after 1 year. Long term successful bronchoscopic management with blade was attained by 99 % in simple and 93% in mixed stenosis and in complex type stenosis. CONCLUSION Our study underlines the importance of the use of the blade in bronchoscopic treatment as a valid conservative approach in the management of patients with inoperable benign tracheal stenosis as an alternative to the use of the laser, reducing the abnormal inflammatory reaction in order to limit recurrences.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00