AI-based synthetic simulation CT generation from diagnostic CT for simulation-free workflow of spinal palliative radiotherapy

preprint OA: closed
📄 Open PDF Full text JSON View at publisher
Full text 5,682 characters · extracted from oa-doi-fallback · 3 sections · click to expand

Abstract

Purpose/Objective Current radiotherapy (RT) planning workflows rely on pre-treatment simulation CT (sCT), which can significantly delay treatment initiation, particularly in resource-constrained settings. While diagnostic CT (dCT) offers a potential alternative for expedited planning, inherent geometric discrepancies from sCT in patient positioning and table curvature limit its direct use for accurate RT planning. This study presents a novel AI-based method designed to overcome these limitations by generating synthetic simulation CT (ssCT) directly from standard dCT for spinal palliative RT, aiming to eliminate the need for sCT and accelerate the treatment workflow. Materials/Methods ssCTs were generated using two neural network models to adjust spine position and correct table curvature. The neural networks use a three-layer structure (ReLU activation), optimized by Adam with MSE loss and MAE metrics. The models were trained on paired dCT and sCT images from 30 patients undergoing palliative spine radiotherapy from a safety-net hospital, with 22 cases used for training and 8 for testing. To explore institutional dependence, the models were also tested on 7 patients from an academic medical center (AMC). To evaluate ssCT accuracy, both ssCT and dCT were aligned with sCT using the same frame of reference rigid registration on bone windows. Dosimetric differences were assessed by comparing dCT vs. sCT and ssCT vs. sCT, quantifying deviations in dose-volume histogram (DVH) metrics, including Dmean, Dmax, D95, D99, V100, V107, and root-mean-square (RMS) differences. The imaging and plan quality was assessed by four radiation oncologists using a Likert score. The Wilcoxon signed-rank test was used to determine whether there is a significant difference between the two methods.

Results

For the safety-net hospital cases, the generated ssCT demonstrated significantly improved geometric and dosimetric accuracy compared to dCT. ssCT reduced the mean difference in key dosimetric parameters (e.g., Dmean difference decreased from 2.0% for dCT vs. sCT to 0.57% for ssCT vs. sCT with significant improvement under the Wilcoxon signed-rank test) and achieved a significant reduction in the RMS difference of DVH curves (from 6.4% to 2.2%). Furthermore, physician evaluations showed that ssCT was consistently rated as significantly superior for treatment planning images (mean scores improving from “Acceptable” for dCT to “Good to Perfect” for ssCT), reflecting improved confidence in target and tissue positioning. In the academic medical-center cohort—where technologists already apply meticulous pre-scan alignment—ssCT still yielded statistically significant, though smaller, improvements in several dosimetric endpoints and in observer ratings.

Conclusion

Our AI-driven approach successfully generates ssCT from dCT that achieves geometric and dosimetric accuracy comparable to sCT for spinal palliative RT planning. By specifically addressing critical discrepancies like spine position and table curvature, this method offers a robust approach to bypass the need for dedicated sCT simulations. This advancement has the potential to significantly streamline the RT workflow, reduce treatment uncertainties, and accelerate time to treatment, offering a highly promising solution for improving access to timely and accurate radiotherapy, especially in limited-resource environments. Competing Interest Statement The authors have declared no competing interest. Funding Statement This study is funded by Radiation Oncology Institute # ROI2024-003. Author Declarations I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained. Yes The details of the IRB/oversight body that provided approval or exemption for the research described are given below: Ethics committee/IRB of Baylor College of Medicine gave ethical approval for this work I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals. Yes I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance). Yes I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable. Yes Footnotes Contact: First author: Yiding.Han{at}bcm.edu 713 2318239 1st Baylor Plaza Houston TX 77030 USA Conflict of interest statement No conflict of interest needs to be reported. Fund statement This study is funded by Radiation Oncology Institute # ROI2024-003. Data sharing statement This study was based on the Baylor St Luke’s Medical Center and Smith Clinic data. The authors do not own these data and hence are not permitted to share them in the original form (only in aggregate form, eg, publications). Research data are stored in an institutional repository and will be shared upon request to the corresponding author. Data Availability All data produced in the present study are available upon reasonable request to the authors

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00