Automatic Detection and Multi-Component Segmentation of BrainMetastases in Longitudinal MRI

preprint OA: closed
View at publisher

Abstract

Abstract Manual segmentation of lesions, required for radiotherapy planning and follow-up, is time-consuming and error-prone. Automatic detection and segmentation can assist radiologists in these tasks. This work explores the automated detection and segmentation of brain metastases (BMs) in longitudinal MRIs. It focuses on several important aspects: identifying and segmenting new lesions for screening and treatment planning, re-segmenting lesions in successive images using prior lesion locations as an additional input channel, and performing multi-component segmentation to distinguish between enhancing tissue, edema, and necrosis. The retrospective data includes 518 metastases in 184 contrast-enhanced T1-weighted MRIs originating from 49 patients (63% male, 37% female). 131 time-points (36 patients, 418 BMs) are used for cross-validation, the remaining 53 time-points (13 patients, 100 BMs) are used for testing. The lesions were manually delineated with label 1: enhancing lesion, label 2: edema, and label 3: necrosis. One-tailed t-tests are used to compare model performance including multiple segmentation and detection metrics. Significance is considered as p$<$0.05. A Dice Similarity Coefficient (DSC) of 0.786 and F1-score of 0.804 are obtained for the segmentation of new lesions. On follow-up scans, the re-segmentation model significantly outperforms the segmentation model (DSC and F1 0.777 and 0.877 vs 0.559 and 0.604). The re-segmentation model also significantly outperforms the simple segmentation model on the enhancing lesion (DSC 0.761 vs 0.525) and edema (0.524 vs 0.465) components, while similar scores are obtained on the necrosis component (0.622 vs 0.627). Additionally, we analyze the correlation between lesion size and segmentation performance, as demonstrated in various studies that highlight the challenges in segmenting small lesions. Our findings indicate that this correlation disappears when utilizing the re-segmentation approach and evaluating with the unbiased normalized DSC. In conclusion, the automated segmentation of new lesions and subsequent re-segmentation in follow-up images was achievable, with high level of performance obtained for single- and multiple-component segmentation tasks.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2024) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00