Comparison of three fundus inspection methods during phacoemulsification in patients with diabetic white cataract

preprint OA: closed
View at publisher

Abstract

Background: The aim of this study was to investigate whether Wild Field Imaging System (WFIS SW-8000), 25G endoilluminator, and intraoperative optical coherence tomography (iOCT) can perform real-time screening and diagnosing in patients with suspicious diabetic retinopathy during phacoemulsification, especially in cases of white cataract that obscures the preoperative view of the retina. Methods: A cross-sectional study was carried out. A total of 204 dense diabetic cataractous eyes of 204 patients with suspected diabetic retinopathy treated at the Affiliated Hospital of Nantong University from April 2020 to March 2021 were included. Lens phacoemulsification combined with intraocular lens implantation was performed. Following the removal of the lens opacity, the 25G endoilluminator, fundus photography, and iOCT were performed successively. Optical coherence tomography (OCT) and/or fundus fluorescein angiography (FFA) were used to verify the fundus findings postoperatively. Intraoperative and postoperative results were compared to verify the accuracy of intraoperative diagnosis in each group. Results: Intraoperative and postoperative examinations revealed 58 and 62 eyes with diabetic retinopathy, respectively (positive rate, 28.43% and 30.39%, respectively). During the phacoemulsification, WFIS SW-8000 detected 44 eyes with diabetic retinopathy (the detection rate, 70.97%); 25G endoilluminator found 56 eyes with diabetic retinopathy (the detection rate, 90.32%); iOCT found 46 eyes with diabetic retinopathy (the detection rate, 74.19%); and 58 eyes with diabetic retinopathy were found by combining the three methods (the detection rate, 93.55%). There were statistically significant differences in the diagnostic sensitivity for diabetic retinopathy among the methods (χ 2 =16.36, P =0.001). Conclusions: WFIS SW-8000, 25G endoilluminator, iOCT, and especially their combination can be used to inspect the fundus and detect diabetic retinopathy intraoperatively; they are helpful for the timely diagnosis and treatment of retinopathy in patients with dense cataract.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00