Intro
Endometrial receptivity (ER) refers to the likelihood of embryo implantation in the endometrium during the window of implantation. ER has been the focus of research for more than 80 years since Rock and Bartlett described histological changes in the endometrium before and after implantation in 1937 ( 1 ). Advances in detection techniques have led to a better understanding of embryo-endometrial dialogue and implant-related processes ( 2 - 4 ). However, few advances have been made in translating this knowledge into methods to provide a clinically meaningful assessment of ER ( 5 ). Many methods for evaluating ER require endometrial biopsies, such as pinocytosis tests, endometrial receptivity array (ERA), and endometrial function tests; these tests are invasive and must be performed during the stimulation cycle, which delays the transplant cycle ( 6 - 8 ). In contrast, ultrasound imaging is noninvasive and reproducible. Ultrasound evaluation of ER includes measurements of endometrial thickness (EMT), endometrial patterns, endometrial volume (EV), and endometrial blood flow ( 9 , 10 ). However, the results of studies using a single ultrasound evaluation of ER are inconsistent ( 11 , 12 ). For example, EMT is widely regarded as a predictor of ER, and a thin EMT is associated with a low in vitro fertilization (IVF) success rate ( 13 ). However, some studies have shown that EMT before transplantation is not significant for predicting IVF outcomes ( 14 - 16 ). Therefore, we aimed to determine whether the changes in endometrial indicators are meaningful for predicting IVF outcomes in frozen embryo transfer (ET) cycles. We present the following article in accordance with the STROBE reporting checklist (available at https://qims.amegroups.com/article/view/10.21037/qims-22-705/rc ).
Methods
This was a prospective cross-sectional study. The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The ethics committee of Dalian Women and Children’s Medical Group approved the research protocol (No. 2020013). All the women who agreed to participate in the study signed informed consent forms. Women who underwent IVF were enrolled between September 2020 and July 2021. The criteria for inclusion were frozen cleavage-stage ETs and transplantation of 1 or 2 high-quality embryos. The exclusion criteria were ultrasonographic findings of a poorly displayed endometrium, uterine malformation, adenomyosis, endometriosis, uterine fibroids, hydrosalpinx, or intrauterine adhesions. Patients to be enrolled underwent an ultrasound examination on the second day of menstruation for detection of items related to the exclusion criteria. For patients identified for enrollment, clinical information was recorded, including age, body mass index (BMI), time of infertility, and levels of the basic hormone indicators estradiol (E2), progesterone, and anti-Müllerian hormone (AMH).
The enrolled patients underwent ultrasound examination 3 times: the day of progesterone administration but before progesterone administration (day P), the third day after progesterone administration (day P + 2), and the day of embryo transplantation (day of ET). Ultrasound examinations were performed from 7 am to 9 am. One doctor with over 20 years of experience in conducting gynecological ultrasounds completed all the examinations. Two-dimensional ultrasound was used to record EMT, 3-dimensional (3D) ultrasound was used to record EV, and 3-dimensional power Doppler (3D-PD) ultrasound imaging was used to record the following endometrial blood flow parameters: vascular index (VI), flow index (FI), and vascular flow index (VFI). First, we validated the intraoperator 3-time measurement agreement for the 3D imaging–related measurements EV, VI, FI, and VFI. All examinations were performed using a Voluson E10 (GE Healthcare) ultrasound machine (probe model RIC5-9-D). The E2 level was tested on day P and day P + 2. For each patient, 2 consecutive changes during the 3 inspections of EMT, EV, VI, FI, and VFI and 1 change during the 2 inspections of the E2 level were categorized as “declining” or “nondeclining” ( Figures 1,2 ). A decrease in a value was considered “declining”, and a value that did not change or that increased was considered “nondeclining”. The relationships between changes in a given indicator and the IVF outcome were analyzed.
Changes in EV. The calculation of EV using 3D TVS. (A-C) EV calculated in the same patient on day P, day P + 2, and day of ET, respectively. The results showed that EV was 4.18 cm 3 , 3.45 cm 3 , and 4.03 cm 3 on day P, day P + 2, and day of ET, respectively. The changes in EV on the day P, day P + 2, and day of ET in the patient were “declining” and “nondeclining”. EV, endometrial volume; 3D, 3-dimensional; TVS, transvaginal ultrasonography; day P, before progesterone administration; d P + 2, the third day after progesterone administration; day of ET, the day of embryo transplantation.
Changes in endometrial blood flow indicators. Calculation of the VI, FI, and VFI using 3D-PD TVS. (A-C) VI, FI, and VFI calculated in the same patient on day P, day P + 2, and day of ET, respectively. The results showed the value of VI was 37.311, 13.078, and 22.036 on day P, day P + 2, and day of ET, respectively. The changes in VI were “declining” and “nondeclining”. The value of FI was 24.202, 17.561, and 20.454 on day P, day P + 2, and day of ET, respectively. The changes in FI were “declining” and “nondeclining”. The value of VFI was 9.030, 2.297, and 4.507 on day P, day P + 2, and day of ET, respectively. The changes in VFI were “declining” and “nondeclining”. VI, vascular index; FI, flow index; VFI, vascular flow index; 3D-PD, 3-dimensional power Doppler; TVS, transvaginal ultrasonography; day P, before progesterone administration; d P + 2, the third day after progesterone administration; day of ET, the day of embryo transplantation.
All patients received hormone replacement therapy (HRT) for endometrium preparation during frozen ET cycles. Treatment started on the second day of menstruation with oral administration of Femoston estradiol tablets (estradiol tablets/estradiol dydrogesterone tablets, 2 mg/10 mg; Abbott Healthcare Products) at a dosage of 2 mg, 2 to 3 times a day, for 10 to 21 days. The medication was adjusted according to the EMT and serum E2 level. Endometrial starting progesterone administration was performed when the EMT was ≥8 mm and the serum E2 level was ≥200 pgl/L. When Femoston estradiol tablets were stopped, 2 to 3 tablets of Femoston estradiol dydrogesterone tablets were administered per day, and progesterone was injected intramuscularly (Guangzhou Baiyun Mountain Pharmaceutical) at 40 mg/d. When the EMT was <8 mm or the serum E2 level was <200 pgl/L, the decision to cancel the transplant was based on the patient’s previous condition. E2 and progesterone levels were tested on the third day of progesterone administration, and arrangements were made for thawing and transplantation. All embryos were frozen and thawed by vitrification. One or two high-quality embryos were transferred. Femoston estradiol dydrogesterone tablets (2–3 tablets per day orally) and progesterone (40 mg intramuscularly) were applied 14 days after starting the transplantation. The blood β-human chorionic gonadotrophin (β-hCG) level was measured.
EMT was measured at the midsagittal section of the uterus. Measurements were made from the outer edge to the outer edge of the endometrial–myometrial interface in the widest part of the endometrium ( 17 ). The 3D model was started with the angle set to 120°, and the uterine volume data were collected and stored. Two sets of 3D volume data were collected. The most satisfactory 3D data were analyzed offline, and VOCAL (Virtual Organ Computer-aided Analysis) software (GE Healthcare) was used. We started from plane B, selected “manual trace”, marked every 15°, and obtained the EV after completion. The average value of 3 measurements was taken.
The PD mode was started at the midsagittal section of the uterus, and the pulse repetition frequency was set to 0.3, and the PD gain was adjusted for a good endometrial blood flow signal. The 3D mode was started, and the angle was set to 120°. The patient was asked to breathe gently and remain as still as possible, and the observer made every effort to limit inappropriate movements of the transducer. Two sets of 3D volume data were collected. The most satisfactory 3D data were analyzed offline, and the EV was obtained. A volume histogram was used to obtain the VI, FI, and VFI. The average value of 3 measurements was taken.
A positive β-hCG blood test 14 days after ET was used to diagnose pregnancy ( 18 ). A clinical pregnancy (CP) was defined as the detection of 1 or more gestational sacs via ultrasound ( 19 ). Pregnancy over 12 weeks was defined as an ongoing pregnancy (OP) ( 20 ).
R 4.0 statistical analysis software (The R Foundation of Statistical Computing) and the Shapiro-Wilk method were used for the normality test. A 2-sample t -test was performed for comparisons between 2 groups of data that were normally distributed with a uniform variance, and a t -test was performed for data with an uneven variance. A Mann-Whitney test was used to compare 2 groups of data that did not satisfy a normal distribution. According to the distribution characteristics of the count data, a chi-squared test, adjusted chi-squared test, or Fisher exact probability test was used. In the univariate difference analysis, a P value <0.1 was included in the multivariate stepwise logistic regression based on the Akaike information criterion. The inspection level was α=0.05.
The sample size was calculated using Power Analysis and Sample Size (PASS) 15 software (NCSS LLC). According to previous reports, the EMT in IVF cycles is 10.43±1.97 mm and 11.88±2.28 mm in pregnant and nonpregnant women, respectively ( 21 ). A group sample size of 80 could achieve an 85% power to reject the null hypothesis with a significance level (α) of 0.050 according to a 2-sided 2-sample unequal-variance t -test.
Results
A total of 133 patients were initially enrolled in this study; 48 patients were excluded, and 85 patients were finally included in the statistical analysis ( Figure 3 ). The characteristics of the study population and baseline data are shown in Table 1 . The intraobserver consistency for 3D measurements of EV, VI, FI, and VFI were 0.994, 0.994, 0.969, and 0.994, respectively ( Table 2 ). Ultrasound values measured at day P, day P + 2, and day of ET are shown in Table 3 . Among the 85 patients, 61 were pregnant (71%, 61/85), 47 had a CP (55%, 47/85), and 39 had an OP (45%, 39/85). Univariate analysis was used to analyze changes in the EMT, EV, VI, FI, VFI, and E2 level. The results showed that for the outcome of pregnancy, none of the indicators analyzed were influencing factors. The changes in EMT, EV, VI, FI, and VFI, as well as P values at the 3 time points, are shown in Figure 4 . Two changes in EV were indicators associated with the outcome of a CP (P=0.005 and P=0.02). For the outcome of an OP, 2 changes in EMT (P=0.04 and P=0.02) and EV were influencing factors (P=0.001 and P=0.007; Table 4 ). After multivariate stepwise regression analysis, the results showed that if the first change in the EV was nondeclining, then the likelihood of a CP was more unfavorable (P=0.03). In the second change, the difference between declining and nondeclining was not significant for a CP (P=0.07). Similarly, if the first change in the EV was nondeclining, then the likelihood of an OP was unfavorable (P=0.01). However, if the second change in the EV on the day of ET was nondeclining, the likelihood of an OP was more favorable (P=0.03; Table 5 ).
Flowchart of the study group. day P, before progesterone administration; d P + 2, the third day after progesterone administration; day of ET, the day of embryo transplantation; 3D-PD, 3-dimensional power Doppler.
Data are presented as mean ± standard deviation or median (interquartile range). **, P<0.01. E2, estradiol; P, progesterone; AMH, anti-Müllerian hormone; BMI, body mass index.
3D, 3-dimensional; CI, confidence interval; EV, endometrial volume; VI, vascular index; FI, flow index; VFI, vascular flow index.
Data are presented as mean ± standard deviation or median (interquartile range). EMT, endometrial thickness; EV, endometrial volume; VI, vascular index; FI, flow index; VFI, vascular flow index; day P, before progesterone administration; d P + 2, the third day after progesterone administration; day of ET, the day of embryo transplantation.
Changes in EMT, EV, VI, FI, and VFI with P values at the 3 time points. (A-C) The P value changes in ultrasound indexes in relation to pregnancy, clinical pregnancy, and continued pregnancy, respectively. day P, before progesterone administration; d P + 2, the third day after progesterone administration; day of ET, the day of embryo transplantation; EMT, endometrial thickness; EV, endometrial volume; VI, vascular index; FI, flow index; VFI, vascular flow index.
*, P<0.05; **, P<0.01. E2, estradiol; EMT, endometrial thickness; EV, endometrial volume; VI, vascular index; FI, flow index; VFI, vascular flow index.
AMH, anti-Müllerian hormone; E2, estradiol; P, progesterone; EV, endometrial volume; ET, embryo transfer; CI, confidence interval; OR, odds ratio.
Discussion
EMT was the earliest ultrasound indicator used to evaluate ER. In the univariate analysis, a first declining change in the EMT and a second nondeclining change in the EMT differed between the OP group and the non-OP group (P=0.04 and P=0.02). Although the changes in the EMT in the multivariate analysis was not an independent predictor, a decline in the EV after progesterone administration had predictive value for a CP and OP (P=0.03 and P=0.01). Meanwhile, a nondeclining change in EV on the day of ET had predictive value for an OP (P=0.03). Regarding the blood flow in the endometrium, some studies have shown that a good endometrial blood supply is necessary for embryo implantation ( 22 , 23 ). However, changes in the VI, FI, and VFI observed via 3D-PD imaging ultimately had no association with the IVF results. Regarding patient hormone levels, neither progesterone at day P + 2 nor changes in E2 at day P + 2 showed an ability to predict the pregnancy outcome. Although the AMH level was included in the multivariate analysis, the overall ability to predict pregnancy, CP and OP was not strong (P=0.16, P=0.05, P=0.05). This finding may be related to the lack of precise uniformity in the timing of hormone measurements.
With the development of ultrasound technology, the 3D imaging function of ultrasound equipment has become almost universal ( 24 ). This universality makes the measurement of EV easier to achieve in clinical practice with good repeatability ( 25 ). Some studies have used EV instead of EMT to predict ER ( 26 ). However, whether EV can be a predictor of pregnancy is controversial. Regardless of whether it is measured on the day of egg collection ( 21 ) or the day of β-hCG detection ( 27 ), EV cannot indicate pregnancy outcome. The reason for this finding may be that in addition to reflecting EMT, EV is mainly affected by the size of the uterus. Monitoring changes in the EV can eliminate the impact of uterus size and thus more accurately reflect the changes in the endometrium. In our study, as in other studies, changes in EMT did not have the ability to predict IVF outcomes ( 28 , 29 ). The measurement of EMT was greatly affected by endometrial peristalsis ( 25 ). In particular, endometrial peristalsis was more evident on day P, which affected the accuracy of the EMT measurement. Perhaps this explains why the thickness measurement could not accurately reflect changes in the endometrium. EV overcame this shortcoming and showed a good predictive ability, becoming an independent predictor of a CP, especially for predicting an OP. In the HRT cycle, the use of progesterone reduces the estrogen receptors in the endometrium. The receptivity of the endometrium requires a reduction in estrogen receptors ( 30 ). The effect of progesterone also decreases the thickness of the transformed endometrium ( 31 ). EV increased on the day of ET compared with day P + 2, which may be related to the rapid and progressive curve of endometrial angiogenesis and interstitial edema during the midluteal phase. These endometrial changes were thought to be conducive to embryo implantation. Therefore, a nondeclining change in the EV on the day of ET was conducive to an OP in this study.
In recent years, studies have shown that sequential changes in the endometrium during the cycle may be related to the outcome of IVF ( 32 ). This study did not use sequential ultrasound examinations during the cycle because we studied the changes in the endometrium during HRT in frozen ET cycles. In this procedure, the doctor did not need to perform daily ultrasound examinations. To avoid increasing the number of examinations for patients, we selected representative time points that were also the time at which clinical ultrasound monitoring was needed. We sought to determine the relationships between ER and the changes revealed by ultrasound at these time points. Additionally, it was hoped that the study results could be translated into clinically usable ER indicators.
In the current study, 25 patients (25/133) were excluded due to unavoidable artifacts in the 3D-PD imaging process, accounting for 18.80% of the enrolled patients, which represented the main sample size loss. The leading causes of artifacts were arterial pulsatility and peristalsis of the pelvic bowel ( 33 ). Moreover, if a patient underwent 3 consecutive ultrasound examinations in the study and color artifacts were present in any 1 examination, that patient was excluded. Our findings on 3D-PD imaging of blood flow changes to predict IVF outcomes were partially identical to those of a recent study ( 12 ). In our study, changes in endometrial blood flow were observed twice before transplantation, but neither change was predictive of the IVF outcome. This finding may be because 3D-PD imaging is not a sufficiently sensitive evaluation method, which is consistent with the findings of another study ( 33 ).
The present study differed from previous studies in that it defined a pregnancy outcome in 3 ways: a pregnancy, a CP, and an OP. Our study found that changes in the EV were a meaningful indicator, and we used the least number of inspections to predict the outcome of IVF. Additionally, compared with other 3D indicators, such as the VI, FI, and VFI, EV is easy to obtain in practice. However, we did not follow up on the birth of the fetuses. In addition, our sample size was relatively small, and we hope to do more related work in the future.
Conclusions
This study of the pattern of changes in endometrial ultrasound indices found that the pattern of changes in EV during the frozen ET cycles was a predictor of IVF outcome. We also found that a decline in EV after progesterone administration and a nondeclining EV before ET were favorable factors for pregnancy.
Supplementary Material
The article’s supplementary files as
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.