Affordable and Effective Optokinetic Response Methods to Assess Visual Acuity and Contrast Sensitivity in Larval to Juvenile Zebrafish

preprint OA: closed
📄 Open PDF View at publisher

Abstract

Background The optokinetic response (OKR) is an effective behavioural assay to investigate functional vision in zebrafish. The rapid and widespread use of gene editing, drug screening and environmental modulation technologies have resulted in a broader need for visual neuroscience researchers to access affordable and more sensitive OKR, contrast sensitivity (CS) and visual acuity (VA) assays. Here, we demonstrate how 2D- and 3D-printed, striped patterns or drums coupled with a motorised base and microscope provide a simple, cost-effective but efficient means to assay OKR, CS and VA in larval-juvenile zebrafish. Results In wild-type, 5 days post-fertilisation (dpf) zebrafish, the 2D or 3D drums printed with the standard OKR stimulus of 0.02 cycles per degree (cpd), 100% black-white contrast evoked equivalent responses of 24.2 or 21.8 saccades per minute, respectively. Furthermore, although the OKR number was significantly reduced compared to the 0.02 cpd drum (p<0.0001), the 2D and 3D drums evoked respectively equivalent responses with the 0.06 and 0.2 cpd drums. Notably, standard OKR responses varied with time of day; peak responses of 29.8 saccades per minute occurred in the early afternoon with significantly reduced responses occurring in the early morning or late afternoon, (18.5 and 18.4 saccades per minute, respectively). A customised series of 2D printed drums enabled analysis of visual acuity and contrast sensitivity in 5-21 dpf zebrafish. The saccadic frequency in visual acuity and contrast sensitivity assays, was inversely proportional to age, spatial frequency and contrast of the stimulus. Conclusions OKR, VA and CS of zebrafish larvae can be efficiently measured using 2D- or 3D-printed striped drums. For data consistency the luminance of the OKR light source, the time of day when the analysis performed, and the order of presentation of VA and CS drums must be considered. These simple methods allow effective and more sensitive analysis of functional vision in zebrafish.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00