XEN®-63 Compared to XEN®-45 Gel Stents to Reduce Intraocular Pressure in Glaucoma
preprint
OA: closed
CC-BY-4.0
Abstract
The XEN® gel stent reduces intraocular pressure (IOP) in glaucoma. XEN®-45 is widely used while the newer XEN®-63 has a larger lumen that may lower IOP more. We retrospectively compared the first 15 XEN®-63 cases to 15 matched XEN®-45 controls. With a preoperative IOP of 18.1 ± 3.9 mmHg (mean ± SD) and a final IOP of 9.2 ± 4.2 mmHg, XEN®-63 implantation resulted in an IOP reduction of 48.0 ± 23.3%. Similarly, with a preoperative IOP of 18.3 ± 4.5 mmHg and a final IOP of 10.5 ± 2.3 mmHg, XEN®-45 implantation resulted in an IOP reduction of 39.5 ± 17.81%. The median follow-up period was 57 days for the XEN®-63 group and 183 days for the XEN®-45 group. 5/15 eyes of each group underwent open conjunctival bleb revision within the period of observation. Two eyes of the XEN®-63 group also had secondary glaucoma surgery. In both groups only one eye required restart of antiglaucomatous medication. XEN®-63 and XEN®-45 effectively lower IOP and medication. XEN-63 achieved lower IOP over a short follow-up. Com-plication and revision rates were similar.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00
- unpaywall
- last seen: 2026-08-16T06:22:10.609676+00:00
License: CC-BY-4.0