Hysterosalpingo-foam sonography (HyFoSy) using two different balloon catheters: a randomized trial

In: Gynecological Surgery · 2014 · vol. 12(1) , pp. 41–44 · doi:10.1007/s10397-014-0867-z · W1966315589
article OA: bronze CC0
AI-generated summary by claude@2026-06+body, 2026-06-11

This randomized trial found a pediatric Foley catheter to be easier to insert and less painful during hysterosalpingo-foam sonography compared to a uVue catheter.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

AI-generated deep summary by claude@2026-06, 2026-06-11 · read from full text

This randomized trial compared technical feasibility and patient-reported pain during hysterosalpingo-foam sonography (HyFoSy) using two 2-mm balloon catheters (uVue vs a pediatric Foley with stylet) in 40 blinded women undergoing tubal patency testing at one hospital, with ultrasound-guided catheter insertion used when smooth insertion failed. Catheter insertion failure occurred in 1 uVue patient (5%) and none in the Foley group, and ultrasound guidance was needed more often with uVue (68% vs 20%); women reported less procedural pain with the pediatric Foley, with a significantly lower median ratio of pain increase relative to baseline ultrasound (1.82 vs 0.54; p=0.005). The study’s main limitations were the small sample size and the inability to blind operators to catheter type. This paper does not explicitly discuss endometriosis or adenomyosis; it was included in the corpus via a keyword match in the upstream search index.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Full text 13,256 characters · extracted from oa-pdf · 6 sections · click to expand

Abstract

The purposes of this study were to evaluate and compare the technical feasibility and the patients’ pain during hysterosalpingo-foam sonography (HyFoSy) using two differ- ent 2-mm balloon catheters. Randomized trial in 46 consecu- tive women referred for tubal patency testing by HyFoSy at the Leuven University Hospital. Six women refused to partic- ipate. Forty women were randomized and blinded as to the catheter used. The patients underwent first a transvaginal ultrasound examination to assess the uterus and the ovaries and to exclude the hydrosalpinx, and subsequently, a HyFoSy was performed using an uVue catheter (Cook Medical, Bloomington, IN, USA) or a pediatric Foley ’sc a t h e t e rw i t h stylet (Pediatric Folysil, Coloplast A/S; Humlebaek, Den- mark) according to randomization. If the catheter could not be inserted smoothly into the uterine cavity at first attempt, transabdominal ultrasound guidance was performed. After the procedure, the patients were asked to fill in a questionnaire including a visual analog scale (V AS) score for the pain at initial ultrasound examination (V AS US), used as baseline score, and at HyFoSy (V AS HyFoSy). The pain related to the HyFoSy procedure was reported as (V AS HyFoSy−VA SUS)/ VA SUS. Catheter insertion failed in one patient of the uVue group (5 % failure rate) and in none of the Foley group. Ultrasound guidance during catheter insertion was performed in 68 % of the uVue group and 20 % of the Foley group. The median ratio (V AS HyFoSy−VA SUS)/V ASUS for the uVue and the Foley group was 1.82 and 0.54, respectively (p=0.00 5). A pediatric Foley catheter was easier to insert as compared to an uVue catheter, and HyFoSy using a pediatric Foley catheter was reported by the women to be the least painful.

Keywords

Ultrasonography . Infertility . Female . Fallopian tube patency tests . Microbubbles

Background

Hysterosalpingo-contrast-sonography (HyCoSy) is as accu- rate as hysterosalpingography (HSG) in the evaluation of Fallopian tube patency and is to be preferred as it does not expose the patient nor the examiner to radiation [ 1–3]. More- over, HyCoSy is reportedly less painful and better tolerated by t h ep a t i e n t sa sc o m p a r e dt oH S G .H y s t e r o s a l p i n g o - f o a ms o - nography (HyFoSy) is a novel variant of HyCoSy using gel foam, a mechanically mixing of water, gel, and air, as a positive contrast agent [4–8]. This study aims to evaluate and compare the technical feasibility and the patients ’ pain during HyFoSy using two different 2-mm balloon catheters.

Methods

We performed a randomized trial in 46 consecutive women referred for tubal patency testing by HyFoSy at the Leuven University Hospital. The study had been approved by the local ethics committee, and informed consent was obtained in all patients. Six women refused to participate. Forty women were randomized (Fig.1) using a random number generator (https:// www.random.org/). The random assignments were placed in 40 numbered, opaque, and sealed envelopes. The envelope was opened after consent was given and just prior to the HyFoSy procedure. The patients were blinded as to the catheter used, but for obvious reasons, the clinician was not blinded. The patients underwent first a transvaginal ultrasound examination to assess the uterus and the ovaries and to exclude the hydrosalpinx, and immediately thereafter, a D. V an Schoubroeck (*) : T. V an den Bosch: L. Ameye : T. D’Hooghe : D. Timmerman KU Leuven Department of Development and Regeneration, University Hospital Leuven, Herestraat 49, 3000 Leuven, Belgium e-mail: [email protected] Gynecol Surg (2015) 12:41–44 DOI 10.1007/s10397-014-0867-z HyFoSy was performed using a 2-mm uVue catheter (Cook Medical, Bloomington, IN, USA) or a 2-mm pediatric Foley’s catheter with stylet (Pediatric Folysil, Coloplast A/S; Humlebaek, Denmark) accordi ng to randomization. The HyFoSy procedure was performed as outlined elsewhere [ 5]. An open-sided Collin speculum was inserted, the cervix disinfected with a water-based Dakin solution, and the cathe- ter was inserted into the uterine cavity. If the catheter could not be inserted smoothly at first attempt, transabdominal ultra- sound guidance was performed. Catheter insertion was per- formed without the use of a cervical tenaculum or a dilator. The balloon was slowly inflated with 0.5 to 1.0 ml of saline in the lower part of the uterine cavity till the patient reported a vague pressure in the lower abdomen indicating perceptible intrauterine pressure. The speculum was removed, and the vaginal ultrasound probe was reinserted. The size of the balloon was measured in three perpendicular diameters, and the gel foam was slowly injected under direct ultrasound control. Tubal patency was defined as a sustained and fast forward flow of the gel foam through the entire Fallopian tube. After the procedure, the patients were asked to fill in a questionnaire including a visual analog scale (V AS) score for the pain at initial ultrasound examination (V AS US), used as baseline score, and at HyFoSy (V ASHyFoSy). The pain related to the HyFoSy procedure was calculated as the median ratio (V ASHyFoSy−VA SUS)/V ASUS. The patients were asked also to describe the pain/discomfort during HyFoSy (as “neutral,”“ unpleasant,” “painful but bearable,” or “really painful”) and to compare the pain/discomfort during HyFoSy with two common minor procedures (i.e., blood sampling and cervical cytology smear) as ‘less,”“ equally,” or “more painful/causing discomfort.” The Fisher’s exact test was used to assess the differences in categorical variables, t test and Wilcoxon test were used to assess differences in continuous variables. SAS 9.4 (SAS Institute Inc., Cary, NC, USA) was used for the statistical analyses. 46 Consecu/g415ve women referred for HyFoSy 40 women randomized uVue N = 20 19 analysed In 1 pa/g415ent the uVue inser/g415on failed (a Foley was inserted) Foley N = 20 20 analysed 6 women refused to par/g415cipate Fig. 1 Study design Ta bl e 1 Patients’ characteristics uVue (n=19)a Foley (n=20 ) Mean age 31 29 Primary subfertility 13 12 Secondary subfertility 6 8 P≥14 5 Unilateral block at HyFoSy 1 3 Bilateral block at HyFoSy 1 0 P parity (all nine cases had a parity of 1) a In one patient randomized in the “uVue” arm, a Foley was used after uVue insertion failed Ta bl e 2 Reported pain/discomfort during HyFoSy uVue Foley N % N % Neutral 1 5.3 2 10.0 Unpleasant 6 31.6 8 40.0 Painful but bearable 7 36.8 8 40.0 Really painful* 5 26.3 2 10.0 Total 19 20 *p value 0.24 Ta bl e 3 Compared to blood sampling *p value 0.48 uVue Foley N % N % Less 0 0.0 2 10.0 Equal 4 21.1 5 25.0 More* 15 78.9 13 65.0 Total 19 20 Ta bl e 4 Compared to cervical cytology smear *p value 0.33 a One patient randomized to the Foley arm did not answer this question uVue Foley N % Na % Less 1 5.3 2 10.5 Equal 5 26.3 7 24.1 More* 13 68.4 10 52.6 Total 19 19 42 Gynecol Surg (2015) 12:41–44 Findings The patients ’ characteristics (age, parity, primary/secondary subfertility) and tubal patency for both subgroups were comparable (Table 1). Catheter insertion failed in one patient of the uVue group (5 % failure rate) and in none of the Foley group. In the patient with failed uVue catheter insertion, a Foley was inserted successfully during the same session. Ultrasound guidance for catheter insertion was performed in 68 % of the uVue group and 20 % of the Foley group ( p=0.00 4). The mean balloon diameter in the uVue group and the Foley group was 8.7 and 9.3 mm, respectively (p=0.22). Five women (26 %) of the uVue group reported the procedure to be really painful versus two (10 %) in the Foley group ( p=0.24) (Table 2). In the uVue group and in the Foley group, 79 and 65 %, respectively, found HyFoSy to be more painful than blood sampling (p=0.48) (Table 3), and 68 and 53 %, respectively, found HyFoSy more painful than a cervical cytology smear (p=0.33) (Table 4). The median V AS US in the uVue and in the Foley group was 1.5 (0.1–4.7) and 1.9 (0–6.5), respectively (p=0.14), while the median V ASHyFoSy was 4.8 (0.6–8.5) and 3.5 (0–7.1), respec- tively ( p=0.10). The median ratio (V AS HyFoSy − VA SUS)/ VA SUS for the uVue and the Foley group was 1.82 and 0.54, respectively (p=0.005) (Fig. 2).

Conclusions

A 2-mm pediatric Foley catheter was easier to insert compared to an uVue catheter, and HyFoSy using a pediatric Foley catheter was reported by the women to be the least painful too. The strength of this study is its strict randomized design, the blinding of the patients, and the fact that the study was performed by the same group in the same center, precluding an operators’ bias. The weaknesses are the relatively small sample size and the impossible operators’ blinding. Both catheters have the same diameter (2 mm) and have a similar balloon at the tip. The main difference is the devices ’ rigidity, the uVue being stiffer. The latter has the advantage to allow insertion without the need of a swab forceps. Moreover, in case of severe ante- or retroversion of the endocervical canal, it can be bent before insertion to match/fit the shape of the canal. However, in case of a tortuous or S-shaped endocervical canal, this may prove to be a disadvantage, since the catheter will keep its pre-bended shape, the tip may “scrape” the more distal part of the canal, thus causing pain. The more difficult insertion is reflected by the significantly higher proportion of patients in the uVue group necessitating ultrasound guidance. Moreover, the catheter ’s stiffness may cause discomfort when inserting the vaginal ultrasound probe and makes the uterus more rigid during ultrasound examina- tion. The Foley’s catheter does not have the above-mentioned disadvantages, because it has a much less rigid and removable stylet to facilitate insertion, and once the stylet has been removed, the catheter is supple. The results of our study favor the use of the Foley’sc a t h e t e r over the uVue catheter in term of patients ’ tolerance and operators’ technical preference. Conflict of interest Dominique V an Schoubroeck, Thierry V an den Bosch, Lieveke Ameye, Thomas D ’Hooghe, and Dirk Timmerman de- clare that they have no conflict of interest. The author’s role in the study can be summarized as follows: D. V an Schoubroeck—participation in study design, execution, anal- ysis, manuscript drafting, and critical discussion; corresponding author T. V an den Bosch—participation in study design, execution, analysis, manuscript drafting, and critical discussion L. Ameye, study design and analysis T. D’Hooghe—critical discussion D. Timmerman—critical discussion Informed consent All procedures followed were in accordance with the ethical standards of the responsible committee on human experimen- tation (institutional and national) and with the Helsinki Declaration of 1975, as revised in 2000 (5). Informed consent was obtained from all patients for being included in the study.

References

1. Campbell S, Bourne TH, Tan SL, Collins WP (1994) Hysterosalpingo contrast sonography (HyCoSy) and its future role within the investi- gation of infertility in Europe. Ultrasound Obstet Gynecol 4:245–253 2. Strandell A, Bourne T, Bergh C, Granberg S, Thorburn J, Hamberger L (2000) A simplified ultrasound based infertility investigation protocol 0 2 4 6 8 10 VAS US VAS HyFoSY uVue 0 2 4 6 8 10 VAS US VAS HyFoSY FOLEY Fig. 2 Pain related to the HyFoSy procedure; for each patient, the reported pain during ultrasound examination (V AS US) and during the HyFoSy procedure (V AS HyFoSy) is presented Gynecol Surg (2015) 12:41–44 43 and its implications for patient management. J Assist Reprod Genet 17: 87–92 3. Lim CP , Hasafa Z, Bhattacharya S, Maheshwari A (2011) Should a hysterosalpingogram be a first-line investigation to diagnose female tubal subfertility in the modern subfertility workup? Hum Reprod 26:967–971 4. Exalto N, Stappers C, van Raamsdonk LA, Emanuel MH (2007) Gel instillation sonohysterography: first experience with a new technique. Fertil Steril 87:152–155 5. Emanuel MH, Exalto N (2011) Hysterosalpingo-foam sonography (HyFoSy): a new technique to visualize tubal patency. Ultrasound Obstet Gynecol 37:497–499 6. Emanuel MH, van Vliet M, Weber M, Exalto N (2012) First experi- ences with hysterosalpingo-foam sonography (HyFoSy) for office tubal patency testing. Hum Reprod 27:114–117 7. V an Schoubroeck D, V an den Bosch T, Meuleman C, Tomassetti C, D ’Hooghe T, Timmerman D (2013) The use of a new gel foam for the evaluation of tubal patency. Gynecol Obstet Investig 75: 152–156 8. V an Schoubroeck D, V an den Bosch T, Ameye L, Boes AS, D’Hooghe T, Timmerman D (2014) Pain during Fallopian tube patency testing by hysterosalpingo-foam-sonogra phy (HyFoSy). Ultrasound Obstet Gynecol. doi:10.1002/uog.14646 44 Gynecol Surg (2015) 12:41–44

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-pdf

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

References (9)

Source provenance

openalex
last seen: 2026-06-10T17:14:06.276822+00:00
License: CC0 · commercial use OK