Optimizing High-Parameter T-Cell Immunophenotyping Through Direct Comparison of Conventional and Spectral Flow Cytometry

preprint OA: closed
Full text JSON View at publisher
Full text 1,892 characters · extracted from oa-doi-fallback · click to expand
Abstract High-parameter flow cytometry is essential for dissecting the intricate landscape of T-cell diversity. In this study, we directly compare conventional flow cytometry (CFC) and spectral flow cytometry (SFC) for high-dimensional T-cell phenotyping, assessing how spectral detection and panel-design strategies influence analytical performance. Using peripheral blood mononuclear cells from healthy donors stained with both an established (v1) and an optimized (v2) fluorochrome-labelled antibody panel, and analyzed through manual gating and unsupervised approaches, we found that CFC reliably identified major T-cell subsets. However, spectral acquisition consistently delivered clear technical advantages, including improved signal-to-noise ratios, higher staining index values, and superior resolution of low-intensity and co-expressed markers. These improvements translated into more sharply delineated multidimensional clusters and a markedly enhanced resolution of T-cell differentiation states. Moreover, the optimized spectral panel enhanced the unsupervised detection of rare populations, such as cytotoxic CD4⁺ T-cells (PD-1⁺GZMB⁺). However, despite the overall increase in data quality achieved with SFC, the selection of antibody clones may influence the measured frequencies of the identified populations. Finally, SFC - particularly when coupled with rational panel optimization and the use of advanced fluorophores - consistently delivers superior, higher-quality measurements and improved multidimensional resolution, thereby substantially enhancing the robustness and sensitivity of high-parameter T-cell phenotyping for comprehensive immunological studies. Competing Interest Statement Kelly Lundsten serves as a consultant to Beckman Coulter, the manufacturer of the CytoFLEX LX flow cytometer and the CytoFLEX mosaic 88 Spectral Detection Module used in this study.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00