Precise Instruction and Consideration of the VerticalandHorizontal Force Component Increase Validity and Reliability of the 90:20 Isometric Posterior Chain Test
preprint
OA: closed
AI-generated summary
This study found that including horizontal force components and measuring applied torque improved the validity and reliability of the 90:20 Isometric Posterior Chain Test for assessing hamstring strength.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
Abstract
Hamstring injuries are associated with decreased hamstring strength. Matinlauri et al.’s 90:20 Isometric Posterior Chain Test (90:20 IPCT) efficiently assesses hamstring strength, but has not been validated so far. Furthermore, their rather unprecise original instruction allows high variability in test execution. We added a new instruction and parameters and examined, whether this measure leads to increased reliability and validity. We assessed hamstring strength of 23 sport students via the 90:20 IPCT under the original instruction, to exert vertical force, and our new instruction, to exert vertical and horizontal force. Instead of only using bare vertical force as outcome parameter under the original (Fz_V) and our new instruction (Fz_VH), we also calculated the resultant force (Fres_VH) and the applied torque onto the force place (M_F_ortho_VH). To test for validity, we correlated the outcome parameters with peak torque of gold standard dynamometry. Furthermore, we measured muscle activities of the mm. rectus femoris, biceps femoris, semitendinosus, and gluteus maximus under our new instruction and compared them to those under the original parameter (Fz_V) via one sample t-tests. To evaluate reliability, tests were repeated on two separate days, for which we calculated intra class correlation coefficients (ICCs) and coefficients of variation (CVs). Our new instruction and parameters (Fz_VH, Fres_VH, M_F_ortho_VH) showed better validity (mean r = 0.77, r = 0.81, and r = 0.85) and equally good or better reliability (ICCs: 0.87, 0.89, and 0.94; CVs: 4.7 %, 4.1 %, and 4.7 %) than the original instruction and parameter (Fz_V) (mean r = 0.70; ICC: 0.91; CV: 5.6 %). There were no differences in muscle activities between the parameters and instructions of the 90:20 IPCT. We recommend our new instruction and the applied torque onto the force plate as it makes the 90:20 IPCT a more reliable and valid tool to assess hamstring strength.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2024) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.
Source provenance
- europepmc
- last seen: 2026-05-20T01:45:00.602351+00:00